Fill, Fold, Photo: Preconcentration and Multiplex Detection of Trace Level Heavy Metals in Water.

IF 8.2 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Prakash Aryal, Jason Boes, Eric Brack, Todd Alexander, Charles S Henry
{"title":"Fill, Fold, Photo: Preconcentration and Multiplex Detection of Trace Level Heavy Metals in Water.","authors":"Prakash Aryal, Jason Boes, Eric Brack, Todd Alexander, Charles S Henry","doi":"10.1021/acssensors.4c01708","DOIUrl":null,"url":null,"abstract":"<p><p>Heavy metal contamination is an increasing global threat to human and environmental health, particularly in resource-limited areas. Traditional platforms for heavy metal detection are labor intensive and expensive and require lab facilities. While paper-based colorimetric sensors offer a simpler approach, their sensitivity limitations prevent them from meeting legislative requirements for many metals. Existing preconcentration systems, on the other hand, can achieve lower detection limits but typically focus on analyzing only one metal, making comprehensive monitoring difficult. We address these limitations by introducing a low-cost preconcentration system coupled with colorimetric analysis for the simultaneous detection of seven metal ions at low ppb levels without the need for external equipment outside a smartphone. The system achieved detection limits of 15 ppb (Ni(II)), 7 ppb (Cu(II)), 2 ppb (Fe(III)), 20 ppb (Cr(VI)), 13 ppb (Pb(II)), 26 ppb (Hg(II)), and 15 ppb (Mn(II)) with six out of seven limits of detection values falling well below EPA regulatory guidelines for drinking water. The user-friendly Fill, Fold, Photo approach eliminates complex pretreatment steps. Smartphone-based detection offers portable quantification within seconds. Employing masking strategies ensured higher selectivity for each assay on the card, while our packaging protocols enable system stability for over 4 weeks of study, facilitating mass production and deployment within a realistic time frame. To validate the sensor's performance in real-world scenarios, the sensor was tested with environmental water samples. The sensor demonstrated good recovery, ranging from 77% to 94% compared to the standard ICP-MS method. Furthermore, spike recovery analysis confirmed the sensor's accuracy, with a relative standard deviation (RSD) of less than 15%. This technology holds significant promise for future development as a convenient, portable solution for field-based monitoring of a broad spectrum of water contaminants, including pesticides, PFAS, fertilizers, and beyond.</p>","PeriodicalId":24,"journal":{"name":"ACS Sensors","volume":null,"pages":null},"PeriodicalIF":8.2000,"publicationDate":"2024-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Sensors","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acssensors.4c01708","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Heavy metal contamination is an increasing global threat to human and environmental health, particularly in resource-limited areas. Traditional platforms for heavy metal detection are labor intensive and expensive and require lab facilities. While paper-based colorimetric sensors offer a simpler approach, their sensitivity limitations prevent them from meeting legislative requirements for many metals. Existing preconcentration systems, on the other hand, can achieve lower detection limits but typically focus on analyzing only one metal, making comprehensive monitoring difficult. We address these limitations by introducing a low-cost preconcentration system coupled with colorimetric analysis for the simultaneous detection of seven metal ions at low ppb levels without the need for external equipment outside a smartphone. The system achieved detection limits of 15 ppb (Ni(II)), 7 ppb (Cu(II)), 2 ppb (Fe(III)), 20 ppb (Cr(VI)), 13 ppb (Pb(II)), 26 ppb (Hg(II)), and 15 ppb (Mn(II)) with six out of seven limits of detection values falling well below EPA regulatory guidelines for drinking water. The user-friendly Fill, Fold, Photo approach eliminates complex pretreatment steps. Smartphone-based detection offers portable quantification within seconds. Employing masking strategies ensured higher selectivity for each assay on the card, while our packaging protocols enable system stability for over 4 weeks of study, facilitating mass production and deployment within a realistic time frame. To validate the sensor's performance in real-world scenarios, the sensor was tested with environmental water samples. The sensor demonstrated good recovery, ranging from 77% to 94% compared to the standard ICP-MS method. Furthermore, spike recovery analysis confirmed the sensor's accuracy, with a relative standard deviation (RSD) of less than 15%. This technology holds significant promise for future development as a convenient, portable solution for field-based monitoring of a broad spectrum of water contaminants, including pesticides, PFAS, fertilizers, and beyond.

Abstract Image

填充、折叠、拍照:水中痕量重金属的预浓缩和多重检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Sensors
ACS Sensors Chemical Engineering-Bioengineering
CiteScore
14.50
自引率
3.40%
发文量
372
期刊介绍: ACS Sensors is a peer-reviewed research journal that focuses on the dissemination of new and original knowledge in the field of sensor science, particularly those that selectively sense chemical or biological species or processes. The journal covers a broad range of topics, including but not limited to biosensors, chemical sensors, gas sensors, intracellular sensors, single molecule sensors, cell chips, and microfluidic devices. It aims to publish articles that address conceptual advances in sensing technology applicable to various types of analytes or application papers that report on the use of existing sensing concepts in new ways or for new analytes.
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信