Polina Kilina , Alex G. Kuchumov , Lyudmila Sirotenko , Vladimir Vassilouk , Sergey Golovin , Andrey Drozdov , Evgeniy V. Sadyrin
{"title":"Influence of porous titanium-based jaw implant structure on osseointegration mechanisms","authors":"Polina Kilina , Alex G. Kuchumov , Lyudmila Sirotenko , Vladimir Vassilouk , Sergey Golovin , Andrey Drozdov , Evgeniy V. Sadyrin","doi":"10.1016/j.jmbbm.2024.106724","DOIUrl":null,"url":null,"abstract":"<div><p>The reconstruction of maxillofacial defects caused by anomalies, fractures, or cancer is challenging for dentofacial surgeons. To produce efficient, patient-specific implants with long-term performance and biological suitability, numerous methods of manufacturing are utilized. Because additive manufacturing makes it possible to fabricate complex pore structure samples, it is now recognized as an acceptable option to design customized implants. It is well recognized that a porous structure with proper design promotes accelerated cell proliferation, which enhances bone remodeling. Porosity can also be employed to modify the mechanical characteristics of fabricated implants. Thus, design and choice of rational lattice structure is an important task. The influence of the structure of jaw implants made of highly porous titanium-based materials on their mechanical properties and bone tissue growth was studied. Based on a 3D computer model of Wigner-Seitz lattice structure, the model samples were fabricated from Ti6Al4V powder by selective laser melting to characterize the mechanical properties of the samples depending on their macroporosity. Then two types of jaw bone implants were manufactured to conduct studies of bone tissue ingrowth when implanted in laboratory animals. The research was carried out in several stages: design and production of the implants for replacing incomplete defects of the lower jaw; implantation of SLM-printed implants in laboratory animals into an artificially produced defect of the lower jaw; analysis of the degree of fixation of the “implant - bone” connection (for implantation periods from 2 weeks to 9 months). During the research, Ti-alloy structures with cell diameters of 2–3 mm and macroporosity of 90–97% mimicking the spongy structure of trabecular bone tissue, were characterized by a compressive strength of 12.47–37.5 MPa and an elastic modulus of 0.19–1.23 GPa, corresponding to the mechanical properties of bone tissue. Active processes of tissue growth into implant cells were detected 2 weeks after implantation, the significant differences in the volume and types of filling tissue depending on the size of the cell were described. Recommendations for choosing the cell size depending on the type of bone tissue damage were given. When using SLM-printed implants with lattice structure (cell sizes from 1 to 3 mm), an active osteosynthesis processes occurred, which culminated in the formation of bone tissue inside the implant cells 9 months after implantation, with 68% of the samples characterized by the maximum degree of implant fixation. Implants with 3 mm cells with macropores diameters of 850 μm were recommended for replacing cavities after removal of perihilar cysts. To replace complete and partial defects, it was recommended to use implants with a cell size of 2 and 3 mm.</p></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":"160 ","pages":"Article 106724"},"PeriodicalIF":3.3000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616124003564","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The reconstruction of maxillofacial defects caused by anomalies, fractures, or cancer is challenging for dentofacial surgeons. To produce efficient, patient-specific implants with long-term performance and biological suitability, numerous methods of manufacturing are utilized. Because additive manufacturing makes it possible to fabricate complex pore structure samples, it is now recognized as an acceptable option to design customized implants. It is well recognized that a porous structure with proper design promotes accelerated cell proliferation, which enhances bone remodeling. Porosity can also be employed to modify the mechanical characteristics of fabricated implants. Thus, design and choice of rational lattice structure is an important task. The influence of the structure of jaw implants made of highly porous titanium-based materials on their mechanical properties and bone tissue growth was studied. Based on a 3D computer model of Wigner-Seitz lattice structure, the model samples were fabricated from Ti6Al4V powder by selective laser melting to characterize the mechanical properties of the samples depending on their macroporosity. Then two types of jaw bone implants were manufactured to conduct studies of bone tissue ingrowth when implanted in laboratory animals. The research was carried out in several stages: design and production of the implants for replacing incomplete defects of the lower jaw; implantation of SLM-printed implants in laboratory animals into an artificially produced defect of the lower jaw; analysis of the degree of fixation of the “implant - bone” connection (for implantation periods from 2 weeks to 9 months). During the research, Ti-alloy structures with cell diameters of 2–3 mm and macroporosity of 90–97% mimicking the spongy structure of trabecular bone tissue, were characterized by a compressive strength of 12.47–37.5 MPa and an elastic modulus of 0.19–1.23 GPa, corresponding to the mechanical properties of bone tissue. Active processes of tissue growth into implant cells were detected 2 weeks after implantation, the significant differences in the volume and types of filling tissue depending on the size of the cell were described. Recommendations for choosing the cell size depending on the type of bone tissue damage were given. When using SLM-printed implants with lattice structure (cell sizes from 1 to 3 mm), an active osteosynthesis processes occurred, which culminated in the formation of bone tissue inside the implant cells 9 months after implantation, with 68% of the samples characterized by the maximum degree of implant fixation. Implants with 3 mm cells with macropores diameters of 850 μm were recommended for replacing cavities after removal of perihilar cysts. To replace complete and partial defects, it was recommended to use implants with a cell size of 2 and 3 mm.
期刊介绍:
The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials.
The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.