Density of fresh wall of acute aortic dissection with synchrotron-based x-ray phase tomography.

0 CARDIAC & CARDIOVASCULAR SYSTEMS
Koki Yokawa,Masato Hoshino,Naoto Yagi,Yutaka Nakashima,Kazunori Nakagawa,Yutaka Okita,Kenji Okada,Takuro Tsukube
{"title":"Density of fresh wall of acute aortic dissection with synchrotron-based x-ray phase tomography.","authors":"Koki Yokawa,Masato Hoshino,Naoto Yagi,Yutaka Nakashima,Kazunori Nakagawa,Yutaka Okita,Kenji Okada,Takuro Tsukube","doi":"10.1093/icvts/ivae157","DOIUrl":null,"url":null,"abstract":"OBJECTIVES\r\nThe mechanisms behind the onset of acute aortic dissection have not been fully elucidated. We developed dynamic Synchrotron-based X-ray phase tomography to quantitatively study the dynamics of biological samples and applied it to the fresh aortic wall in acute type-A aortic dissection.\r\n\r\nMETHODS\r\nFresh, ring-shaped aortas undergoing aortic repair in acute type-A aortic dissection were measured in a container filled with normal cold saline within 24 hours of surgery. As a control, we obtained five formalin-fixed normal ascending aortas from autopsies (female : 2, 59.7 (SD : 5.5) years). To evaluate the quantitative morphological change, we estimated the density at five each step stretched by 2 mm per step. The fresh specimens were analyzed pathologically about the area ratio of elastic fibre.\r\n\r\nRESULTS\r\nSamples were obtained from five patients (1 man and 4 women, 59.4 (SD: 8.7) years) The overall density of the tunica media in the fresh aorta was 1.062(SD : 0.006) g/cm3 and differed significantly between the dissected and non-dissected portion (1.05(SD : 0.004) vs 1.066(SD : 0.004) g/cm3, respectively; p = 0.0122). When the fresh aortic wall was stretched and became thinner, the density of the tunica media remained unchanged. Compared with pathological findings, area ratio of the elastic fibre of the tunica media were lower in non-dissected portion than normal (48.6 (SD : 7.1) % v.s 60.5 (SD : 5.7) %, p < 0.001).\r\n\r\nCONCLUSIONS\r\nDynamic-XPCT can trace the deformation process that occurs in situ in fresh aorta in acute type-A aortic dissection. We confirmed that densitometric property of the aortic wall in acute type-A aortic dissection was unchanged during the stretching process.","PeriodicalId":73406,"journal":{"name":"Interdisciplinary cardiovascular and thoracic surgery","volume":"9 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interdisciplinary cardiovascular and thoracic surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/icvts/ivae157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

OBJECTIVES The mechanisms behind the onset of acute aortic dissection have not been fully elucidated. We developed dynamic Synchrotron-based X-ray phase tomography to quantitatively study the dynamics of biological samples and applied it to the fresh aortic wall in acute type-A aortic dissection. METHODS Fresh, ring-shaped aortas undergoing aortic repair in acute type-A aortic dissection were measured in a container filled with normal cold saline within 24 hours of surgery. As a control, we obtained five formalin-fixed normal ascending aortas from autopsies (female : 2, 59.7 (SD : 5.5) years). To evaluate the quantitative morphological change, we estimated the density at five each step stretched by 2 mm per step. The fresh specimens were analyzed pathologically about the area ratio of elastic fibre. RESULTS Samples were obtained from five patients (1 man and 4 women, 59.4 (SD: 8.7) years) The overall density of the tunica media in the fresh aorta was 1.062(SD : 0.006) g/cm3 and differed significantly between the dissected and non-dissected portion (1.05(SD : 0.004) vs 1.066(SD : 0.004) g/cm3, respectively; p = 0.0122). When the fresh aortic wall was stretched and became thinner, the density of the tunica media remained unchanged. Compared with pathological findings, area ratio of the elastic fibre of the tunica media were lower in non-dissected portion than normal (48.6 (SD : 7.1) % v.s 60.5 (SD : 5.7) %, p < 0.001). CONCLUSIONS Dynamic-XPCT can trace the deformation process that occurs in situ in fresh aorta in acute type-A aortic dissection. We confirmed that densitometric property of the aortic wall in acute type-A aortic dissection was unchanged during the stretching process.
基于同步加速器的 X 射线相位断层扫描显示急性主动脉夹层新鲜壁的密度。
目的急性主动脉夹层的发病机制尚未完全阐明。我们开发了基于同步加速器的动态 X 射线相位断层成像技术来定量研究生物样本的动态变化,并将其应用于急性 A 型主动脉夹层中的新鲜主动脉壁。方法在手术后 24 小时内,在一个装有正常冷盐水的容器中测量急性 A 型主动脉夹层中接受主动脉修复的新鲜环形主动脉。作为对照,我们从尸体解剖中获得了五条福尔马林固定的正常升主动脉(女:2,59.7(SD:5.5)岁)。为了评估形态学的定量变化,我们估算了每拉伸 2 毫米,拉伸 5 步时的密度。结果样本来自五名患者(1 名男性和 4 名女性,59.4(SD:8.7)岁)。062(SD : 0.006) 克/立方厘米,解剖部分和未解剖部分之间存在显著差异(分别为 1.05(SD : 0.004) vs 1.066(SD : 0.004) 克/立方厘米;p = 0.0122)。当新鲜主动脉壁被拉伸变薄时,中膜的密度保持不变。与病理结果相比,未剥离部分的中膜弹性纤维面积比低于正常部分(48.6 (SD : 7.1) % v.s 60.5 (SD : 5.7) %, p < 0.001)。我们证实急性 A 型主动脉夹层主动脉壁的密度特性在拉伸过程中保持不变。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信