Jessica S West,Rachel D Stelmach,Howard W Francis,Xianxin Zhu,Ching-Heng Wu,Melissa A Stockton,Elizabeth Troutman Adams,Gabriel Madson,John D Kraemer,Laura Nyblade
{"title":"Preliminary Validation of Hearing Device-Related Stigma Measures in Four United States Populations.","authors":"Jessica S West,Rachel D Stelmach,Howard W Francis,Xianxin Zhu,Ching-Heng Wu,Melissa A Stockton,Elizabeth Troutman Adams,Gabriel Madson,John D Kraemer,Laura Nyblade","doi":"10.1097/aud.0000000000001539","DOIUrl":null,"url":null,"abstract":"OBJECTIVES\r\nAlthough hearing devices such as cochlear implants and hearing aids often improve communication, many people who are d/Deaf or hard of hearing (d/DHH) choose not to use them. Hearing device-related stigma, or negative societal beliefs about people who use hearing devices, often drives this decision. Although much research has documented the negative effects of hearing device-related stigma, no widely accepted, validated measure to quantify such stigma across populations currently exists. In this article, we describe the preliminary validation of four distinct but related scales measuring hearing device-related stigma in different populations, including people who use hearing devices and those close to them.\r\n\r\nDESIGN\r\nWe preliminarily validated four measures for quantifying hearing device-related stigma in different populations that were previously developed and refined through a literature review, Delphi interviews, cognitive interviews, and a pretest. We preliminarily validated these measures through self-administered online surveys in a convenience sample in the United States. Among participants who use a hearing device and who either (a) self-identified as being d/DHH before they developed language (lifelong; n = 78) or (b) those who self-identified as having acquired a d/DHH identity after they developed language (acquired n = 71), we validated an anticipated hearing device-related stigma scale (d/DHHS-LE-HDA). We validated three scales that measure perceived hearing device-related stigma observed by parents of children who are d/DHH and who use a hearing device (n = 79) (d/DHHS-P-HDPO), care partners of adults who are d/DHH and use a hearing device (n = 108) (d/DHHS-CP-HDPO), and health care providers (n = 203) (d/DHHS-HCP-HDSH). Exploratory factor analysis assessed the reliability of each measure.\r\n\r\nRESULTS\r\nEach of the four scales loaded onto one factor. Factor loadings for the eight-item scale measuring anticipated hearing device-related stigma among the two populations with lived experience ranged from 0.635 to 0.910, with an ordinal α of 0.93 in the lifelong d/DHH participants and 0.94 among the acquired d/DHH participants. The six-item scale of perceived stigma observed by parents had item loadings from 0.630 to 0.920 (α = 0.91). The nine-item scale of hearing device-related stigma observed by care partners had item loadings from 0.554 to 0.922 (α = 0.95). The eight-item scale of hearing device-related stigma reported by health care providers had item loadings from 0.647 to 0.941 (α = 0.89).\r\n\r\nCONCLUSIONS\r\nPreliminary validation results show that the four stigma measures perform well in their respective populations. The anticipated stigma scale performed similarly well for both lifelong d/DHH and acquired d/DHH, which suggests that it could perform well in different contexts. Future research should further validate the scales described here as well as measure hearing device-related stigma in different populations-including people who live in different geographic regions and people using different kinds of hearing devices-and evaluate the success of interventions developed to reduce hearing device-related stigma.","PeriodicalId":55172,"journal":{"name":"Ear and Hearing","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ear and Hearing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/aud.0000000000001539","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
OBJECTIVES
Although hearing devices such as cochlear implants and hearing aids often improve communication, many people who are d/Deaf or hard of hearing (d/DHH) choose not to use them. Hearing device-related stigma, or negative societal beliefs about people who use hearing devices, often drives this decision. Although much research has documented the negative effects of hearing device-related stigma, no widely accepted, validated measure to quantify such stigma across populations currently exists. In this article, we describe the preliminary validation of four distinct but related scales measuring hearing device-related stigma in different populations, including people who use hearing devices and those close to them.
DESIGN
We preliminarily validated four measures for quantifying hearing device-related stigma in different populations that were previously developed and refined through a literature review, Delphi interviews, cognitive interviews, and a pretest. We preliminarily validated these measures through self-administered online surveys in a convenience sample in the United States. Among participants who use a hearing device and who either (a) self-identified as being d/DHH before they developed language (lifelong; n = 78) or (b) those who self-identified as having acquired a d/DHH identity after they developed language (acquired n = 71), we validated an anticipated hearing device-related stigma scale (d/DHHS-LE-HDA). We validated three scales that measure perceived hearing device-related stigma observed by parents of children who are d/DHH and who use a hearing device (n = 79) (d/DHHS-P-HDPO), care partners of adults who are d/DHH and use a hearing device (n = 108) (d/DHHS-CP-HDPO), and health care providers (n = 203) (d/DHHS-HCP-HDSH). Exploratory factor analysis assessed the reliability of each measure.
RESULTS
Each of the four scales loaded onto one factor. Factor loadings for the eight-item scale measuring anticipated hearing device-related stigma among the two populations with lived experience ranged from 0.635 to 0.910, with an ordinal α of 0.93 in the lifelong d/DHH participants and 0.94 among the acquired d/DHH participants. The six-item scale of perceived stigma observed by parents had item loadings from 0.630 to 0.920 (α = 0.91). The nine-item scale of hearing device-related stigma observed by care partners had item loadings from 0.554 to 0.922 (α = 0.95). The eight-item scale of hearing device-related stigma reported by health care providers had item loadings from 0.647 to 0.941 (α = 0.89).
CONCLUSIONS
Preliminary validation results show that the four stigma measures perform well in their respective populations. The anticipated stigma scale performed similarly well for both lifelong d/DHH and acquired d/DHH, which suggests that it could perform well in different contexts. Future research should further validate the scales described here as well as measure hearing device-related stigma in different populations-including people who live in different geographic regions and people using different kinds of hearing devices-and evaluate the success of interventions developed to reduce hearing device-related stigma.
期刊介绍:
From the basic science of hearing and balance disorders to auditory electrophysiology to amplification and the psychological factors of hearing loss, Ear and Hearing covers all aspects of auditory and vestibular disorders. This multidisciplinary journal consolidates the various factors that contribute to identification, remediation, and audiologic and vestibular rehabilitation. It is the one journal that serves the diverse interest of all members of this professional community -- otologists, audiologists, educators, and to those involved in the design, manufacture, and distribution of amplification systems. The original articles published in the journal focus on assessment, diagnosis, and management of auditory and vestibular disorders.