Impact of double stent retriever configuration on first-pass effect in stroke: a multicenter study

IF 4.5 1区 医学 Q1 NEUROIMAGING
Carlos Pérez-García, Miguel Castaño, Juan Carlos Llibre, Luis Vargas, Alfonso López-Frías, Santiago Rosati, Jose Luis López, Jesus Venegas, Eva González, Jon Fondevila, Mariano Espinosa de Rueda, Joaquín Zamarro, Sebastián Baldi, Teresa Díaz, Carmen de la Rosa, Juan Chaviano Grajera, Federico Ballenilla Marco, Victor Cuba, José M Muñoz Olmedo, Jose Carlos Mendez, Sebastian Remollo, Rebeca Bermejo, Edison Morales, Carlos Gómez-Escalonilla, Manuel Moreu
{"title":"Impact of double stent retriever configuration on first-pass effect in stroke: a multicenter study","authors":"Carlos Pérez-García, Miguel Castaño, Juan Carlos Llibre, Luis Vargas, Alfonso López-Frías, Santiago Rosati, Jose Luis López, Jesus Venegas, Eva González, Jon Fondevila, Mariano Espinosa de Rueda, Joaquín Zamarro, Sebastián Baldi, Teresa Díaz, Carmen de la Rosa, Juan Chaviano Grajera, Federico Ballenilla Marco, Victor Cuba, José M Muñoz Olmedo, Jose Carlos Mendez, Sebastian Remollo, Rebeca Bermejo, Edison Morales, Carlos Gómez-Escalonilla, Manuel Moreu","doi":"10.1136/jnis-2024-022297","DOIUrl":null,"url":null,"abstract":"Background Efficient recanalization of occluded cerebral arteries is crucial in the treatment of acute ischemic stroke. Double stent retrievers have shown the potential to enhance the rates of recanalization on the first pass. This study aims to evaluate the efficacy and safety of the double stent retriever technique and the predictors of achieving first-pass effect in patients with acute ischemic stroke. Methods This prospective multicenter study involved 209 patients from 16 comprehensive stroke centers in Spain. Patients with occlusions in the anterior circulation were treated using the Aperio Hybrid double stent retriever. The study examined various deployment techniques, including simultaneous and sequential deployment and stent configurations, comparing the Y-shaped and parallel configurations. Results The double stent retriever technique achieved a first-pass effect in 72.7% of cases and a final successful recanalization rate of 99.5%. The Y-shaped configuration was significantly associated with higher recanalization rates on the first pass (OR 2.59, 95% CI 1.18 to 5.68, P=0.02). Procedural complications were mild to moderate in 6.7% and severe in 1.5% of cases, with symptomatic intracranial hemorrhage occurring in 3.3% of patients. At 3 months follow-up, 57.2% of patients achieved a good clinical outcome, with a mortality rate of 15.1%. Conclusion The findings support the efficacy of the double stent retriever technique, particularly the Y-shaped configuration, in achieving high recanalization rates on the first pass with an acceptable safety profile. This technique may offer clinical benefits for future acute ischemic stroke treatment protocols. Data are available upon reasonable request.","PeriodicalId":16411,"journal":{"name":"Journal of NeuroInterventional Surgery","volume":null,"pages":null},"PeriodicalIF":4.5000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of NeuroInterventional Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/jnis-2024-022297","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NEUROIMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background Efficient recanalization of occluded cerebral arteries is crucial in the treatment of acute ischemic stroke. Double stent retrievers have shown the potential to enhance the rates of recanalization on the first pass. This study aims to evaluate the efficacy and safety of the double stent retriever technique and the predictors of achieving first-pass effect in patients with acute ischemic stroke. Methods This prospective multicenter study involved 209 patients from 16 comprehensive stroke centers in Spain. Patients with occlusions in the anterior circulation were treated using the Aperio Hybrid double stent retriever. The study examined various deployment techniques, including simultaneous and sequential deployment and stent configurations, comparing the Y-shaped and parallel configurations. Results The double stent retriever technique achieved a first-pass effect in 72.7% of cases and a final successful recanalization rate of 99.5%. The Y-shaped configuration was significantly associated with higher recanalization rates on the first pass (OR 2.59, 95% CI 1.18 to 5.68, P=0.02). Procedural complications were mild to moderate in 6.7% and severe in 1.5% of cases, with symptomatic intracranial hemorrhage occurring in 3.3% of patients. At 3 months follow-up, 57.2% of patients achieved a good clinical outcome, with a mortality rate of 15.1%. Conclusion The findings support the efficacy of the double stent retriever technique, particularly the Y-shaped configuration, in achieving high recanalization rates on the first pass with an acceptable safety profile. This technique may offer clinical benefits for future acute ischemic stroke treatment protocols. Data are available upon reasonable request.
双支架截留器配置对脑卒中首通效果的影响:一项多中心研究
背景 在治疗急性缺血性中风的过程中,对闭塞的脑动脉进行高效再通畅至关重要。双支架回取器已显示出提高首次再通率的潜力。本研究旨在评估双支架回取器技术的有效性和安全性,以及急性缺血性脑卒中患者获得首通效果的预测因素。方法 这项前瞻性多中心研究涉及西班牙 16 个综合卒中中心的 209 名患者。前循环闭塞的患者使用 Aperio Hybrid 双支架回流器进行治疗。研究考察了各种部署技术,包括同步和顺序部署以及支架配置,并对 Y 型和平行配置进行了比较。结果 72.7%的病例采用了双支架介入技术,最终再通率达到 99.5%。Y型结构与更高的首次再通率有明显相关性(OR 2.59,95% CI 1.18 至 5.68,P=0.02)。6.7%的患者出现轻度至中度手术并发症,1.5%的患者出现严重并发症,3.3%的患者出现症状性颅内出血。在 3 个月的随访中,57.2% 的患者临床疗效良好,死亡率为 15.1%。结论 研究结果表明,双支架回取器技术,尤其是 Y 型结构的双支架回取器技术,在实现高首次再通畅率的同时,还具有可接受的安全性。该技术可为未来的急性缺血性脑卒中治疗方案带来临床益处。如有合理要求,可提供相关数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
9.50
自引率
14.60%
发文量
291
审稿时长
4-8 weeks
期刊介绍: The Journal of NeuroInterventional Surgery (JNIS) is a leading peer review journal for scientific research and literature pertaining to the field of neurointerventional surgery. The journal launch follows growing professional interest in neurointerventional techniques for the treatment of a range of neurological and vascular problems including stroke, aneurysms, brain tumors, and spinal compression.The journal is owned by SNIS and is also the official journal of the Interventional Chapter of the Australian and New Zealand Society of Neuroradiology (ANZSNR), the Canadian Interventional Neuro Group, the Hong Kong Neurological Society (HKNS) and the Neuroradiological Society of Taiwan.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信