Determining the Degree of Sulfo-tag Conjugation to AAV5 Vectors by LC-HRMS and Evaluating the Effects on Antibody Binding Affinity and Bridging Assay Sensitivity

Yanshan Dai, Xinqun Wu, Xiaowei Sun, Daniel Cohen, Divakar Rajeswaran, Scott Robotham, Shannon Chilewski, Kun Yang, Graham Yearwood, Alexander Kozhich, Vibha Jawa
{"title":"Determining the Degree of Sulfo-tag Conjugation to AAV5 Vectors by LC-HRMS and Evaluating the Effects on Antibody Binding Affinity and Bridging Assay Sensitivity","authors":"Yanshan Dai, Xinqun Wu, Xiaowei Sun, Daniel Cohen, Divakar Rajeswaran, Scott Robotham, Shannon Chilewski, Kun Yang, Graham Yearwood, Alexander Kozhich, Vibha Jawa","doi":"10.1208/s12248-024-00970-2","DOIUrl":null,"url":null,"abstract":"<p>Pre-existing anti-AAV antibodies can be detected using ligand binding-based assay formats. One such format is the MSD-based bridging assay, which uses sulfo-tag-labeled AAV vectors as detection reagents. However, no method has been developed to accurately measure the degree of sulfo-tag labeling on AAV vectors. To fill this gap, we developed a liquid chromatography-high resolution mass spectrometry (LC-HRMS) method to assess the degree of labeling (DoL) of sulfo-tag on AAV5 vectors, enabling the measurement of the DoL on AAV5 at six increasing levels of sulfo-tag challenge ratio. In addition, a Biacore-based assay was used to evaluate the binding affinity between an anti-AAV5 monoclonal antibody and various sulfo-tag labeled AAV5 vectors. The results indicated that increased DoL of sulfo-tag labeling on AAV5 did not compromise the binding affinity.</p><p>Our study further employed the MSD-bridging assay to detect the binding Signal/Noise (S/N) ratios of four anti-AAV5 monoclonal antibodies (mAbs) to various sulfo-tag-labeled AAV5 vectors. The findings revealed a strong correlation between the degree of sulfo-tag labeling and both the S/N ratios and the sensitivity of MSD bridging assays. This result underscores the importance of optimizing the labeling of detection reagents to enhance assay sensitivity for detecting anti-AAV5 antibodies.</p><h3 data-test=\"abstract-sub-heading\">Graphical Abstract</h3>\n","PeriodicalId":501692,"journal":{"name":"The AAPS Journal","volume":"65 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The AAPS Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1208/s12248-024-00970-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Pre-existing anti-AAV antibodies can be detected using ligand binding-based assay formats. One such format is the MSD-based bridging assay, which uses sulfo-tag-labeled AAV vectors as detection reagents. However, no method has been developed to accurately measure the degree of sulfo-tag labeling on AAV vectors. To fill this gap, we developed a liquid chromatography-high resolution mass spectrometry (LC-HRMS) method to assess the degree of labeling (DoL) of sulfo-tag on AAV5 vectors, enabling the measurement of the DoL on AAV5 at six increasing levels of sulfo-tag challenge ratio. In addition, a Biacore-based assay was used to evaluate the binding affinity between an anti-AAV5 monoclonal antibody and various sulfo-tag labeled AAV5 vectors. The results indicated that increased DoL of sulfo-tag labeling on AAV5 did not compromise the binding affinity.

Our study further employed the MSD-bridging assay to detect the binding Signal/Noise (S/N) ratios of four anti-AAV5 monoclonal antibodies (mAbs) to various sulfo-tag-labeled AAV5 vectors. The findings revealed a strong correlation between the degree of sulfo-tag labeling and both the S/N ratios and the sensitivity of MSD bridging assays. This result underscores the importance of optimizing the labeling of detection reagents to enhance assay sensitivity for detecting anti-AAV5 antibodies.

Graphical Abstract

Abstract Image

通过 LC-HRMS 确定 AAV5 载体的磺酸标签共轭程度并评估其对抗体结合亲和力和桥接测定灵敏度的影响
可以使用基于配体结合的检测方法来检测预先存在的抗 AAV 抗体。其中一种方法是基于 MSD 的桥接检测法,它使用磺标记的 AAV 向量作为检测试剂。然而,目前还没有一种方法能精确测量 AAV 向量上磺基标记的程度。为了填补这一空白,我们开发了一种液相色谱-高分辨质谱(LC-HRMS)方法来评估 AAV5 载体上 sulfo-tag 的标记程度(DoL),该方法可以测量 AAV5 在六个递增的 sulfo-tag 挑战比水平上的 DoL。此外,还使用了一种基于 Biacore 的检测方法来评估抗 AAV5 单克隆抗体与各种 sulfo-tag 标记的 AAV5 载体之间的结合亲和力。我们的研究进一步采用 MSD 桥接测定法检测了四种抗 AAV5 单克隆抗体(mAbs)与各种磺基标记的 AAV5 载体的结合信噪比(S/N)。研究结果表明,磺基标记的程度与信噪比和 MSD 桥接测定的灵敏度之间存在很强的相关性。这一结果强调了优化检测试剂标记以提高检测抗AAV5抗体灵敏度的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信