Converting an HLA‐B27 flow assay from the BD FACSCanto to the BD FACSLyric

IF 2.3 3区 医学 Q3 MEDICAL LABORATORY TECHNOLOGY
Eugene V. Ravkov, Miguel F. Ventura, Swapna Gudipaty, David Ng, Julio C. Delgado, Leo Lin
{"title":"Converting an HLA‐B27 flow assay from the BD FACSCanto to the BD FACSLyric","authors":"Eugene V. Ravkov, Miguel F. Ventura, Swapna Gudipaty, David Ng, Julio C. Delgado, Leo Lin","doi":"10.1002/cyto.b.22206","DOIUrl":null,"url":null,"abstract":"HLA‐B27 is a major histocompatibility complex (MHC) class I antigen which exhibits strong association (90%) with ankylosing spondylitis. HLA‐B27 detection in patients by flow cytometry is a widely used clinical test, performed on many different flow cytometer models. We sought to develop and validate a test conversion protocol for the HLA‐B27 test performed on the BD FACSCanto to BD's newer FACSLyric flow cytometers. The development and validation experiments were performed using anti‐HLA‐B27*FITC/CD3*PE antibody‐stained whole blood patient specimens. The anti‐HLA‐B27*FITC logarithmic median fluorescence (LMF) results on the BD FACSCanto were converted to median fluorescence intensity (MFI) values on the BD FACSLyric. Clustering of the HLA‐B27 positive and negative values, using a 3rd order polynomial equation, resulted in a conversion of the BD FACSCanto cutoff values, negative (<150 LMF) and positive (≥160 LMF), to negative (<4530 MFI) and positive (≥6950 MFI) on the BD FACSLyric. Accuracy was assessed by comparing the flow results obtained on the BD FACSCanto and BD FACSLyric to a molecular PCR based assay. Additional validation parameters (compensation verification, intra‐ and inter‐assay precision, and instrument comparison) were performed per the recommendations outlined in the Clinical and Laboratory Standards Institute (CLSI) H62 guidelines for validation of flow cytometry assays.","PeriodicalId":10883,"journal":{"name":"Cytometry Part B: Clinical Cytometry","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cytometry Part B: Clinical Cytometry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/cyto.b.22206","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

HLA‐B27 is a major histocompatibility complex (MHC) class I antigen which exhibits strong association (90%) with ankylosing spondylitis. HLA‐B27 detection in patients by flow cytometry is a widely used clinical test, performed on many different flow cytometer models. We sought to develop and validate a test conversion protocol for the HLA‐B27 test performed on the BD FACSCanto to BD's newer FACSLyric flow cytometers. The development and validation experiments were performed using anti‐HLA‐B27*FITC/CD3*PE antibody‐stained whole blood patient specimens. The anti‐HLA‐B27*FITC logarithmic median fluorescence (LMF) results on the BD FACSCanto were converted to median fluorescence intensity (MFI) values on the BD FACSLyric. Clustering of the HLA‐B27 positive and negative values, using a 3rd order polynomial equation, resulted in a conversion of the BD FACSCanto cutoff values, negative (<150 LMF) and positive (≥160 LMF), to negative (<4530 MFI) and positive (≥6950 MFI) on the BD FACSLyric. Accuracy was assessed by comparing the flow results obtained on the BD FACSCanto and BD FACSLyric to a molecular PCR based assay. Additional validation parameters (compensation verification, intra‐ and inter‐assay precision, and instrument comparison) were performed per the recommendations outlined in the Clinical and Laboratory Standards Institute (CLSI) H62 guidelines for validation of flow cytometry assays.
将 BD FACSCanto 的 HLA-B27 流式检测转换为 BD FACSLyric
HLA-B27 是一种主要组织相容性复合体(MHC)Ⅰ类抗原,与强直性脊柱炎的关系密切(90%)。通过流式细胞仪检测患者体内的 HLA-B27 是一种广泛应用的临床检测方法,可在多种不同型号的流式细胞仪上进行。我们试图为在 BD FACSCanto 流式细胞仪上进行的 HLA-B27 检测与 BD 最新的 FACSLyric 流式细胞仪的检测转换协议进行开发和验证。开发和验证实验使用抗-HLA-B27*FITC/CD3*PE 抗体染色的病人全血标本进行。将 BD FACSCanto 上的抗 HLA-B27*FITC 对数中位荧光 (LMF) 结果转换成 BD FACSLyric 上的中位荧光强度 (MFI) 值。使用三阶多项式方程对 HLA-B27 阳性和阴性值进行聚类,将 BD FACSCanto 临界值阴性(<150 LMF)和阳性(≥160 LMF)转换为 BD FACSLyric 上的阴性(<4530 MFI)和阳性(≥6950 MFI)。通过将 BD FACSCanto 和 BD FACSLyric 上获得的血流结果与基于分子 PCR 的检测方法进行比较,评估了准确性。其他验证参数(补偿验证、测定内和测定间精度以及仪器比较)是根据临床和实验室标准协会(CLSI)H62 流式细胞仪测定验证指南中的建议进行的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.80
自引率
32.40%
发文量
51
审稿时长
>12 weeks
期刊介绍: Cytometry Part B: Clinical Cytometry features original research reports, in-depth reviews and special issues that directly relate to and palpably impact clinical flow, mass and image-based cytometry. These may include clinical and translational investigations important in the diagnostic, prognostic and therapeutic management of patients. Thus, we welcome research papers from various disciplines related [but not limited to] hematopathologists, hematologists, immunologists and cell biologists with clinically relevant and innovative studies investigating individual-cell analytics and/or separations. In addition to the types of papers indicated above, we also welcome Letters to the Editor, describing case reports or important medical or technical topics relevant to our readership without the length and depth of a full original report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信