Surface-coated PVDF@TAPEG selective ultrafiltration membranes: an investigation on membranes’ hydrophilicity, and antifouling characteristics for effective humic acid removal from wastewater

IF 5.7 3区 环境科学与生态学 Q1 WATER RESOURCES
Leila Emadinezhad, Bita Ayati
{"title":"Surface-coated PVDF@TAPEG selective ultrafiltration membranes: an investigation on membranes’ hydrophilicity, and antifouling characteristics for effective humic acid removal from wastewater","authors":"Leila Emadinezhad,&nbsp;Bita Ayati","doi":"10.1007/s13201-024-02291-3","DOIUrl":null,"url":null,"abstract":"<div><p>This research aimed to synthesize polyvinyl fluoride membranes and coat them with tannic acid (TA) nanoparticles and polyethylene glycol (PEG) additives so that the membrane’s removal efficacy for humic acid (HA) pollutant from agricultural wastewater was investigated. Thus, six membranes with PEG:TA ratios of 0:0, 1:0, 0:1, 1:1, 4:1, and 1:4 were synthesized. Then, the membranes’ characteristics were identified by FTIR-ATR, FESEM, and AFM analysis, and HA’s particle size and zeta potential were also investigated. Based on optimizing effective parameters, the operating pressure of 1.5 bar and HA concentration of 80 ppm were selected as optimal values. The membrane with PEG:TA = 4:1, as the optimally modified membrane, had a pure water flux of 446.03 L/m<sup>2</sup>.h, effluent flux of 72.43 L/m<sup>2</sup>.h, and pollutant removal rate of 86.62% at pH = 7 after 60 min had passed. These values for the pristine membrane (PEG:TA = 0:0) were 265.64 L/m<sup>2</sup>.h, 89.39 L/m<sup>2</sup>.h, and 75.59%, respectively. The results showed that although the effluent flux was lower in the optimized modified membrane than in the pristine membrane, HA removal percentage was increased.</p></div>","PeriodicalId":8374,"journal":{"name":"Applied Water Science","volume":"14 10","pages":""},"PeriodicalIF":5.7000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s13201-024-02291-3.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Water Science","FirstCategoryId":"93","ListUrlMain":"https://link.springer.com/article/10.1007/s13201-024-02291-3","RegionNum":3,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"WATER RESOURCES","Score":null,"Total":0}
引用次数: 0

Abstract

This research aimed to synthesize polyvinyl fluoride membranes and coat them with tannic acid (TA) nanoparticles and polyethylene glycol (PEG) additives so that the membrane’s removal efficacy for humic acid (HA) pollutant from agricultural wastewater was investigated. Thus, six membranes with PEG:TA ratios of 0:0, 1:0, 0:1, 1:1, 4:1, and 1:4 were synthesized. Then, the membranes’ characteristics were identified by FTIR-ATR, FESEM, and AFM analysis, and HA’s particle size and zeta potential were also investigated. Based on optimizing effective parameters, the operating pressure of 1.5 bar and HA concentration of 80 ppm were selected as optimal values. The membrane with PEG:TA = 4:1, as the optimally modified membrane, had a pure water flux of 446.03 L/m2.h, effluent flux of 72.43 L/m2.h, and pollutant removal rate of 86.62% at pH = 7 after 60 min had passed. These values for the pristine membrane (PEG:TA = 0:0) were 265.64 L/m2.h, 89.39 L/m2.h, and 75.59%, respectively. The results showed that although the effluent flux was lower in the optimized modified membrane than in the pristine membrane, HA removal percentage was increased.

Abstract Image

表面涂层 PVDF@TAPEG 选择性超滤膜:研究膜的亲水性和防污特性以有效去除废水中的腐植酸
本研究旨在合成聚氟乙烯膜,并在膜上涂覆单宁酸(TA)纳米颗粒和聚乙二醇(PEG)添加剂,从而研究膜对农业废水中腐植酸(HA)污染物的去除效果。因此,合成了六种 PEG:TA 比例为 0:0、1:0、0:1、1:1、4:1 和 1:4 的膜。然后,通过 FTIR-ATR、FESEM 和 AFM 分析确定了膜的特性,并研究了 HA 的粒度和 zeta 电位。在优化有效参数的基础上,选择了 1.5 巴的操作压力和 80 ppm 的 HA 浓度作为最佳值。PEG:TA = 4:1 的膜为最佳改性膜,60 分钟后,在 pH = 7 的条件下,纯水通量为 446.03 L/m2.h,污水通量为 72.43 L/m2.h,污染物去除率为 86.62%。原始膜(PEG:TA = 0:0)的这一数值分别为 265.64 升/平方米.小时、89.39 升/平方米.小时和 75.59%。结果表明,虽然优化改性膜的污水通量低于原始膜,但 HA 的去除率却提高了。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Applied Water Science
Applied Water Science WATER RESOURCES-
CiteScore
9.90
自引率
3.60%
发文量
268
审稿时长
13 weeks
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信