Refining ECG interpretation: From false assumptions to evidence-based precision

IF 1.3 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
José Nunes de Alencar MD , Claudio Cirenza MD, PhD , Angelo Amato Vincenzo de Paola MD, PhD
{"title":"Refining ECG interpretation: From false assumptions to evidence-based precision","authors":"José Nunes de Alencar MD ,&nbsp;Claudio Cirenza MD, PhD ,&nbsp;Angelo Amato Vincenzo de Paola MD, PhD","doi":"10.1016/j.jelectrocard.2024.153803","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Electrocardiography (ECG) remains a fundamental tool in cardiovascular diagnostics, frequently relying on System 1 thinking—rapid, intuitive pattern recognition (PR). However, this approach can be insufficient when dealing with complex cases where diagnostic precision is essential. This article emphasizes the importance of integrating System 2 thinking—a more deliberate, evidence-based approach—into ECG interpretation to enhance diagnostic accuracy and avoid clinical errors.</p></div><div><h3>Methods</h3><p>This review examines the distinction between findings that can be adequately managed through System 1 PR and those requiring System 2 reasoning supported by diagnostic accuracy studies.</p></div><div><h3>Results</h3><p>While System 1 PR is effective for recognizing routine ECG findings and self-evident truths, it falls short in conditions where the ECG serves as a mere surrogate marker for underlying pathology. Examples such as false-negative acute coronary occlusions illustrate the need for System 2 reasoning to account for the limitations of ECG's diagnostic precision. Relying solely on System 1 in these contexts risks treating the ECG as an infallible diagnostic tool and as a false gold standard for many diseases, which it is not.</p></div><div><h3>Conclusion</h3><p>To prevent diagnostic errors, ECG interpretation must distinguish between self-evident truths suited for PR and findings that require System 2 reasoning due to their association with actual pathology. Clinicians and educators should prioritize evidence-based methods, incorporating System 2 reasoning into practice to improve diagnostic precision and patient outcomes.</p></div>","PeriodicalId":15606,"journal":{"name":"Journal of electrocardiology","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of electrocardiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022073624002735","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Electrocardiography (ECG) remains a fundamental tool in cardiovascular diagnostics, frequently relying on System 1 thinking—rapid, intuitive pattern recognition (PR). However, this approach can be insufficient when dealing with complex cases where diagnostic precision is essential. This article emphasizes the importance of integrating System 2 thinking—a more deliberate, evidence-based approach—into ECG interpretation to enhance diagnostic accuracy and avoid clinical errors.

Methods

This review examines the distinction between findings that can be adequately managed through System 1 PR and those requiring System 2 reasoning supported by diagnostic accuracy studies.

Results

While System 1 PR is effective for recognizing routine ECG findings and self-evident truths, it falls short in conditions where the ECG serves as a mere surrogate marker for underlying pathology. Examples such as false-negative acute coronary occlusions illustrate the need for System 2 reasoning to account for the limitations of ECG's diagnostic precision. Relying solely on System 1 in these contexts risks treating the ECG as an infallible diagnostic tool and as a false gold standard for many diseases, which it is not.

Conclusion

To prevent diagnostic errors, ECG interpretation must distinguish between self-evident truths suited for PR and findings that require System 2 reasoning due to their association with actual pathology. Clinicians and educators should prioritize evidence-based methods, incorporating System 2 reasoning into practice to improve diagnostic precision and patient outcomes.

完善心电图解读:从错误假设到循证精确
导言心电图(ECG)仍然是心血管诊断的基本工具,经常依赖于系统 1 思维--快速、直观的模式识别(PR)。然而,在处理诊断精确度至关重要的复杂病例时,这种方法可能不够充分。本文强调了在心电图解读中融入第二系统思维的重要性--第二系统思维是一种更深思熟虑、以证据为基础的方法,可提高诊断准确性并避免临床错误。结果虽然第一系统思维能有效识别常规心电图结果和不言自明的真理,但在心电图仅作为潜在病理的替代标记的情况下,第一系统思维就显得力不从心了。假阴性急性冠状动脉闭塞等例子说明,需要用系统 2 推理来解释心电图诊断精确性的局限性。结论为防止诊断错误,心电图解读必须区分适合 PR 的不言自明的真理和因与实际病理相关而需要系统 2 推理的结果。临床医生和教育工作者应优先考虑循证方法,将系统 2 推理纳入实践,以提高诊断精确度和患者预后。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of electrocardiology
Journal of electrocardiology 医学-心血管系统
CiteScore
2.70
自引率
7.70%
发文量
152
审稿时长
38 days
期刊介绍: The Journal of Electrocardiology is devoted exclusively to clinical and experimental studies of the electrical activities of the heart. It seeks to contribute significantly to the accuracy of diagnosis and prognosis and the effective treatment, prevention, or delay of heart disease. Editorial contents include electrocardiography, vectorcardiography, arrhythmias, membrane action potential, cardiac pacing, monitoring defibrillation, instrumentation, drug effects, and computer applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信