Optimal high-pressure correlation for transcritical CO2 cycle in direct expansion solar assisted heat pumps

IF 6.7 2区 工程技术 Q1 CONSTRUCTION & BUILDING TECHNOLOGY
{"title":"Optimal high-pressure correlation for transcritical CO2 cycle in direct expansion solar assisted heat pumps","authors":"","doi":"10.1016/j.jobe.2024.110616","DOIUrl":null,"url":null,"abstract":"<div><p>Heat demand may be met sustainably by a solar-assisted heat pump that CO<sub>2</sub> as a refrigerant. This is made possible by the employment of an ecologically benign refrigerant and a renewable energy source that enhances system performance. At the ideal high pressure, the CO<sub>2</sub> heat pump running in a transcritical cycle will function at its highest coefficient of performance (COP). In that way, this study aims to present correlations for calculating the optimum high pressure in a CO<sub>2</sub> direct expansion solar assisted heat pump (DX-SAHP). In this study a mathematical model for compressor, solar evaporator and gas cooler was developed and validated experimentally. The mean difference between the mathematical model and experimental results are −3.9%. Two new equations are proposed to calculate the optimum high pressure in a CO<sub>2</sub> DX-SAHP. The first one considered environment temperature, water outlet temperature and evaporating temperature, which are easy to measure. These facilities the use of correlation to control the heat pump. The second one considered environment temperature, water outlet temperature and solar radiation, which are more suitable for designing CO<sub>2</sub> DX-SAHP. A data base with 100 optimum points was used to curve fitting. Another data base with 50 optimum points was used to compare the results obtained from curve fitting and correlations for the optimum high pressure available in the literature. The proposed correlations shown a maximum error lower than 10.2% despite of the correlations available in the literature from which the errors are about 30%.</p></div>","PeriodicalId":15064,"journal":{"name":"Journal of building engineering","volume":null,"pages":null},"PeriodicalIF":6.7000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of building engineering","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352710224021843","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Heat demand may be met sustainably by a solar-assisted heat pump that CO2 as a refrigerant. This is made possible by the employment of an ecologically benign refrigerant and a renewable energy source that enhances system performance. At the ideal high pressure, the CO2 heat pump running in a transcritical cycle will function at its highest coefficient of performance (COP). In that way, this study aims to present correlations for calculating the optimum high pressure in a CO2 direct expansion solar assisted heat pump (DX-SAHP). In this study a mathematical model for compressor, solar evaporator and gas cooler was developed and validated experimentally. The mean difference between the mathematical model and experimental results are −3.9%. Two new equations are proposed to calculate the optimum high pressure in a CO2 DX-SAHP. The first one considered environment temperature, water outlet temperature and evaporating temperature, which are easy to measure. These facilities the use of correlation to control the heat pump. The second one considered environment temperature, water outlet temperature and solar radiation, which are more suitable for designing CO2 DX-SAHP. A data base with 100 optimum points was used to curve fitting. Another data base with 50 optimum points was used to compare the results obtained from curve fitting and correlations for the optimum high pressure available in the literature. The proposed correlations shown a maximum error lower than 10.2% despite of the correlations available in the literature from which the errors are about 30%.

直接膨胀式太阳能辅助热泵中跨临界二氧化碳循环的最佳高压相关性
以二氧化碳为制冷剂的太阳能辅助热泵可持续地满足供热需求。由于采用了对生态无害的制冷剂和可提高系统性能的可再生能源,这一切都成为可能。在理想的高压条件下,以跨临界循环方式运行的二氧化碳热泵将以最高的性能系数(COP)发挥作用。因此,本研究旨在提出二氧化碳直接膨胀式太阳能辅助热泵(DX-SAHP)最佳高压的相关计算方法。本研究建立了压缩机、太阳能蒸发器和气体冷却器的数学模型,并进行了实验验证。数学模型与实验结果之间的平均差异为-3.9%。为计算 CO2 DX-SAHP 的最佳高压,提出了两个新方程。第一个方程考虑了易于测量的环境温度、出水温度和蒸发温度。这些都有助于利用相关性来控制热泵。第二种方法考虑了环境温度、出水温度和太阳辐射,更适合设计 CO2 DX-SAHP。使用了一个包含 100 个最佳点的数据库进行曲线拟合。另一个数据库包含 50 个最佳点,用于比较曲线拟合结果和文献中的最佳高压相关性。尽管文献中的相关系数误差约为 30%,但建议的相关系数显示最大误差低于 10.2%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of building engineering
Journal of building engineering Engineering-Civil and Structural Engineering
CiteScore
10.00
自引率
12.50%
发文量
1901
审稿时长
35 days
期刊介绍: The Journal of Building Engineering is an interdisciplinary journal that covers all aspects of science and technology concerned with the whole life cycle of the built environment; from the design phase through to construction, operation, performance, maintenance and its deterioration.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信