SIL-IS LC–ESI–MS/MS method for simultaneous quick detection of amoxicillin and clavulanic acid in human plasma: Development, validation and its application to a pharmacokinetics study
Jianbang Wu, Changmao Wang, Rong Zhang, Pengfei Du, Yaqin Wang, Ping Wu, Xinyan Chen, Yunzhe Huang, Yuanwei Jia, Jie Shen
{"title":"SIL-IS LC–ESI–MS/MS method for simultaneous quick detection of amoxicillin and clavulanic acid in human plasma: Development, validation and its application to a pharmacokinetics study","authors":"Jianbang Wu, Changmao Wang, Rong Zhang, Pengfei Du, Yaqin Wang, Ping Wu, Xinyan Chen, Yunzhe Huang, Yuanwei Jia, Jie Shen","doi":"10.1002/bmc.5964","DOIUrl":null,"url":null,"abstract":"<p>A liquid chromatography electrospray ionization tandem mass spectrometry method with amoxicillin-d<sub>4</sub> as the stable isotope-labeled internal standard for simultaneous quick detection of amoxicillin and clavulanic acid in human plasma was developed and validated. Chromatographic separations were performed on a Hedera ODS-2 column (2.1 × 150 mm, 5 μm). The mobile phases for gradient elution were aqueous solution containing 0.2% acetic acid (AA) (mobile phase A) together with organic phase solution (acetonitrile and methanol mixed solution, mobile phase B). Mass spectrometry was performed using negative electrospray ionization in multiple reaction monitoring mode. The target fragment ion pairs of amoxicillin, clavulanic acid and amoxicillin-d<sub>4</sub> were <i>m/z</i> 364.1 → 223.1, 198.1 → 135.9 and 368.1 → 227.1, respectively. The linear ranges of this method were 40–5,000 ng/ml for amoxicillin and 30–2,500 ng/ml for clavulanic acid, with coefficient of determination > 0.9900. This method validation included selectivity, standard curve, lower limit of quantitation, accuracy, precision, recovery, matrix effect (hemolytic matrix and hyperlipidemic matrix), carryover, stability, dilution reliability and incurred sample reanalysis study. A successful application of this method was realized in a pharmacokinetic study after administration of amoxicillin–clavulanic acid potassium granules.</p>","PeriodicalId":8861,"journal":{"name":"Biomedical Chromatography","volume":"38 11","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Chromatography","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bmc.5964","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
A liquid chromatography electrospray ionization tandem mass spectrometry method with amoxicillin-d4 as the stable isotope-labeled internal standard for simultaneous quick detection of amoxicillin and clavulanic acid in human plasma was developed and validated. Chromatographic separations were performed on a Hedera ODS-2 column (2.1 × 150 mm, 5 μm). The mobile phases for gradient elution were aqueous solution containing 0.2% acetic acid (AA) (mobile phase A) together with organic phase solution (acetonitrile and methanol mixed solution, mobile phase B). Mass spectrometry was performed using negative electrospray ionization in multiple reaction monitoring mode. The target fragment ion pairs of amoxicillin, clavulanic acid and amoxicillin-d4 were m/z 364.1 → 223.1, 198.1 → 135.9 and 368.1 → 227.1, respectively. The linear ranges of this method were 40–5,000 ng/ml for amoxicillin and 30–2,500 ng/ml for clavulanic acid, with coefficient of determination > 0.9900. This method validation included selectivity, standard curve, lower limit of quantitation, accuracy, precision, recovery, matrix effect (hemolytic matrix and hyperlipidemic matrix), carryover, stability, dilution reliability and incurred sample reanalysis study. A successful application of this method was realized in a pharmacokinetic study after administration of amoxicillin–clavulanic acid potassium granules.
期刊介绍:
Biomedical Chromatography is devoted to the publication of original papers on the applications of chromatography and allied techniques in the biological and medical sciences. Research papers and review articles cover the methods and techniques relevant to the separation, identification and determination of substances in biochemistry, biotechnology, molecular biology, cell biology, clinical chemistry, pharmacology and related disciplines. These include the analysis of body fluids, cells and tissues, purification of biologically important compounds, pharmaco-kinetics and sequencing methods using HPLC, GC, HPLC-MS, TLC, paper chromatography, affinity chromatography, gel filtration, electrophoresis and related techniques.