Objective quantification of posterior capsule opacification using swept-source anterior segment optical coherence tomography

Shuya Tao, Feiyan Liang, Shuxin Fan, Mingwei Wang, Yimeng Zhang, Xialin Liu, Chang He
{"title":"Objective quantification of posterior capsule opacification using swept-source anterior segment optical coherence tomography","authors":"Shuya Tao, Feiyan Liang, Shuxin Fan, Mingwei Wang, Yimeng Zhang, Xialin Liu, Chang He","doi":"10.1097/j.jcrs.0000000000001546","DOIUrl":null,"url":null,"abstract":"Purpose: To objectively quantify posterior capsule opacification (PCO) using swept-source anterior segment optical coherence tomography (SS-ASOCT) in pseudophakic eyes. Setting: Zhongshan Ophthalmic Center, Guangzhou, China Design: Prospective cross-sectional study. Methods: One hundred and eighty eyes with PCO (37 multifocal intraocular lenses [MfIOLs] and 143 monofocal intraocular lenses [MoIOLs]) were enrolled. The PCO Irregular Degree (PID), defined to evaluate the surface irregularity of PCO, the average and maximum thickness of PCO (AT-PCO, MT-PCO) were applied to quantify PCO based on SS-ASOCT (CASIA2) images. Corrected distance visual acuity (CDVA), high order aberrations (HOAs), modulation transfer function (MTF) and Strehl ratio were recorded. The associations between SS-ASOCT parameters and visual function parameters were assessed by Spearman’s correlation analysis. Results: PID, AT-PCO and MT-PCO showed significant correlations with CDVA, Strehl ratio and HOAs (CDVA: r = 0.702, 0.741, 0.736; Strehl ratio: r = -0.746, -0.719, -0.740; HOAs: r = 0.762, 0.734, 0.752). The correlations of these three parameters with Strehl ratio and HOAs were significantly higher than those of clinical PCO grading with Strehl ratio and HOAs (all P < 0.05). Particularly, PID demonstrated notable correlations with Strehl ratio and HOAs. In addition, patients with MfIOLs presented worse Strehl ratio and HOAs than those with MoIOLs after matching age, PID, AT-PCO and MT-PCO. Conclusions: This study provides a novel method for objectively quantifying PCO using successive cross-sectional SS-ASOCT images. AT-PCO, MT-PCO and PID are presented as new indicators to document PCO severity, with PID offering a unique perspective by considering the irregularity aspect of PCO.","PeriodicalId":15233,"journal":{"name":"Journal of Cataract & Refractive Surgery","volume":"26 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cataract & Refractive Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001546","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To objectively quantify posterior capsule opacification (PCO) using swept-source anterior segment optical coherence tomography (SS-ASOCT) in pseudophakic eyes. Setting: Zhongshan Ophthalmic Center, Guangzhou, China Design: Prospective cross-sectional study. Methods: One hundred and eighty eyes with PCO (37 multifocal intraocular lenses [MfIOLs] and 143 monofocal intraocular lenses [MoIOLs]) were enrolled. The PCO Irregular Degree (PID), defined to evaluate the surface irregularity of PCO, the average and maximum thickness of PCO (AT-PCO, MT-PCO) were applied to quantify PCO based on SS-ASOCT (CASIA2) images. Corrected distance visual acuity (CDVA), high order aberrations (HOAs), modulation transfer function (MTF) and Strehl ratio were recorded. The associations between SS-ASOCT parameters and visual function parameters were assessed by Spearman’s correlation analysis. Results: PID, AT-PCO and MT-PCO showed significant correlations with CDVA, Strehl ratio and HOAs (CDVA: r = 0.702, 0.741, 0.736; Strehl ratio: r = -0.746, -0.719, -0.740; HOAs: r = 0.762, 0.734, 0.752). The correlations of these three parameters with Strehl ratio and HOAs were significantly higher than those of clinical PCO grading with Strehl ratio and HOAs (all P < 0.05). Particularly, PID demonstrated notable correlations with Strehl ratio and HOAs. In addition, patients with MfIOLs presented worse Strehl ratio and HOAs than those with MoIOLs after matching age, PID, AT-PCO and MT-PCO. Conclusions: This study provides a novel method for objectively quantifying PCO using successive cross-sectional SS-ASOCT images. AT-PCO, MT-PCO and PID are presented as new indicators to document PCO severity, with PID offering a unique perspective by considering the irregularity aspect of PCO.
利用扫源前段光学相干断层扫描客观量化后囊不透明情况
目的:使用扫源前段光学相干断层扫描(SS-ASOCT)客观量化假性眼球的后囊不透明(PCO)。地点中国广州中山眼科中心 设计:前瞻性横断面研究:前瞻性横断面研究。方法:对 180 只假性角膜屈光不正的眼球进行前瞻性横断面研究:入组 180 例 PCO 患者(37 例多焦点眼内透镜 [MfIOLs] 和 143 例单焦点眼内透镜 [MoIOLs])。根据 SS-ASOCT (CASIA2) 图像,采用用于评估 PCO 表面不规则程度的 PCO 不规则度 (PID)、PCO 平均厚度和最大厚度 (AT-PCO、MT-PCO) 来量化 PCO。同时还记录了校正距离视力(CDVA)、高阶像差(HOAs)、调制传递函数(MTF)和Strehl比值。通过斯皮尔曼相关分析评估了 SS-ASOCT 参数与视觉功能参数之间的关联。结果显示PID、AT-PCO 和 MT-PCO 与 CDVA、Strehl 比值和 HOAs 呈显著相关(CDVA:r = 0.702、0.741、0.736;Strehl 比值:r = -0.746、-0.719、-0.740;HOAs:r = 0.762、0.734、0.752)。这三个参数与 Strehl 比率和 HOAs 的相关性明显高于 PCO 临床分级与 Strehl 比率和 HOAs 的相关性(所有 P 均为 0.05)。特别是,PID 与 Strehl 比值和 HOAs 的相关性非常明显。此外,在匹配年龄、PID、AT-PCO 和 MT-PCO 后,MfIOLs 患者的 Strehl 比值和 HOAs 比 MoIOLs 患者更差。结论:本研究提供了一种利用连续横断面 SS-ASOCT 图像客观量化 PCO 的新方法。AT-PCO、MT-PCO 和 PID 是记录 PCO 严重程度的新指标,其中 PID 通过考虑 PCO 的不规则性提供了一个独特的视角。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信