Silver Core Coated with Molecularly Imprinted Polymer as Adsorbent in Pipet-Tip Solid Phase Extraction for Neonicotinoids Determination from Coconut Water
Laíse Aparecida Fonseca Dinali, Anny Talita Maria da Silva, Keyller Bastos Borges
{"title":"Silver Core Coated with Molecularly Imprinted Polymer as Adsorbent in Pipet-Tip Solid Phase Extraction for Neonicotinoids Determination from Coconut Water","authors":"Laíse Aparecida Fonseca Dinali, Anny Talita Maria da Silva, Keyller Bastos Borges","doi":"10.1021/acsmeasuresciau.4c00036","DOIUrl":null,"url":null,"abstract":"In this work, we report an innovative adsorbent named Ag-MPS@MIP that has a core@shell structure, i.e., silver nanoparticles modified with 3-methacryloxypropyltrimethoxysilane as the core and molecularly imprinted polymer based on methacrylic acid as its shell. Thiamethoxam, imidacloprid, and acetamiprid were extracted from coconut water samples using Ag-MPS@MIP in pipet-tip solid phase, prior to high-performance liquid chromatography analysis. The separation was carried out on isocratic mode using a mobile phase consisting of C18 column (Phenomenex, 150 mm × 4.6 mm, 5 μm), ultrapure water acidified with 0.3% phosphoric acid:acetonitrile (78:22, v/v), flow rate at 1.0 mL min<sup>–1</sup>, injection volume of 10 μL, temperature of 25 °C, and wavelength at 260 nm. The adsorbent and precursor materials were properly characterized by different instrumental techniques. The main factors affecting the recovery of analytes from coconut water samples by pipet-tip solid phase were optimized, such as sample volume (250 μL), sample pH (pH = 5.0), ionic strength (1%, m/v), washing solvent (300 μL ultrapure water), volume and type of eluent (500 μL methanol), amount of adsorbent (15 mg), cycle of percolation–dispensing (1×), and reuse (5×). Thereby, the neonicotinoids presented extraction recoveries between 82.80 and 96.36%, enrichment factor of 5, linearity ranged from 15 to 4000 ng mL<sup>–1</sup>, correlation coefficient (<i>r</i>) > 0.99, limit of detection of 5 ng mL<sup>–1</sup>, satisfactory selectivity, stability, and proper precision (RSD%: 0.52–9.64%) and accuracy (RE%: −5.19–6.45%). The method was successfully applied to real samples of coconut water.","PeriodicalId":29800,"journal":{"name":"ACS Measurement Science Au","volume":"25 1","pages":""},"PeriodicalIF":4.6000,"publicationDate":"2024-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Measurement Science Au","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1021/acsmeasuresciau.4c00036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
In this work, we report an innovative adsorbent named Ag-MPS@MIP that has a core@shell structure, i.e., silver nanoparticles modified with 3-methacryloxypropyltrimethoxysilane as the core and molecularly imprinted polymer based on methacrylic acid as its shell. Thiamethoxam, imidacloprid, and acetamiprid were extracted from coconut water samples using Ag-MPS@MIP in pipet-tip solid phase, prior to high-performance liquid chromatography analysis. The separation was carried out on isocratic mode using a mobile phase consisting of C18 column (Phenomenex, 150 mm × 4.6 mm, 5 μm), ultrapure water acidified with 0.3% phosphoric acid:acetonitrile (78:22, v/v), flow rate at 1.0 mL min–1, injection volume of 10 μL, temperature of 25 °C, and wavelength at 260 nm. The adsorbent and precursor materials were properly characterized by different instrumental techniques. The main factors affecting the recovery of analytes from coconut water samples by pipet-tip solid phase were optimized, such as sample volume (250 μL), sample pH (pH = 5.0), ionic strength (1%, m/v), washing solvent (300 μL ultrapure water), volume and type of eluent (500 μL methanol), amount of adsorbent (15 mg), cycle of percolation–dispensing (1×), and reuse (5×). Thereby, the neonicotinoids presented extraction recoveries between 82.80 and 96.36%, enrichment factor of 5, linearity ranged from 15 to 4000 ng mL–1, correlation coefficient (r) > 0.99, limit of detection of 5 ng mL–1, satisfactory selectivity, stability, and proper precision (RSD%: 0.52–9.64%) and accuracy (RE%: −5.19–6.45%). The method was successfully applied to real samples of coconut water.
期刊介绍:
ACS Measurement Science Au is an open access journal that publishes experimental computational or theoretical research in all areas of chemical measurement science. Short letters comprehensive articles reviews and perspectives are welcome on topics that report on any phase of analytical operations including sampling measurement and data analysis. This includes:Chemical Reactions and SelectivityChemometrics and Data ProcessingElectrochemistryElemental and Molecular CharacterizationImagingInstrumentationMass SpectrometryMicroscale and Nanoscale systemsOmics (Genomics Proteomics Metabonomics Metabolomics and Bioinformatics)Sensors and Sensing (Biosensors Chemical Sensors Gas Sensors Intracellular Sensors Single-Molecule Sensors Cell Chips Arrays Microfluidic Devices)SeparationsSpectroscopySurface analysisPapers dealing with established methods need to offer a significantly improved original application of the method.