{"title":"Long-term isoagglutinin monitoring after ABO-incompatible kidney transplantation.","authors":"Han Joo Kim,Yousun Chung,Hyungsuk Kim,Youngmin Ko,Young Hoon Kim,Sang-Hyun Hwang,Heung-Bum Oh,Dae-Hyun Ko","doi":"10.1093/ajcp/aqae122","DOIUrl":null,"url":null,"abstract":"OBJECTIVES\r\nThis study aimed to evaluate whether a 2-week period of daily isoagglutinin titer testing after ABO-incompatible kidney transplantation (ABOi-KT) is sufficient to ensure successful engraftment and to advocate for an extension of the monitoring duration in specific situations.\r\n\r\nMETHODS\r\nWe reviewed patients from January 2022 to December 2023 at Asan Medical Center who underwent therapeutic plasma exchange (TPE) due to elevated ABO antibody titers and suspected acute antibody-mediated rejection (AMR) after ABOi-KT. Data collected included pre- and posttransplantation laboratory results, clinical and procedural information, imaging studies, and needle biopsy results of the renal graft.\r\n\r\nRESULTS\r\nWe encountered 3 cases of acute AMR 2 weeks after transplantation. All cases exhibited simultaneous increases in anti-ABO antibody isoagglutinin titers, creatinine, and C-reactive protein levels. Clinical signs, including fever, suggested possible infection, and renal graft biopsy, confirmed AMR in all cases. Two cases underwent graftectomy, while the third recovered renal function after conservative treatment, including TPE.\r\n\r\nCONCLUSIONS\r\nOur findings suggest that a 2-week monitoring period for isoagglutinin titers after ABOi-KT may not be sufficient to detect late AMR. Extending the monitoring duration and considering lifelong fresh-frozen plasma transfusion with graft-compatible blood types, along with periodic isoagglutinin titer testing in cases of suspected AMR, may improve long-term graft outcomes.","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ajcp/aqae122","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

OBJECTIVES This study aimed to evaluate whether a 2-week period of daily isoagglutinin titer testing after ABO-incompatible kidney transplantation (ABOi-KT) is sufficient to ensure successful engraftment and to advocate for an extension of the monitoring duration in specific situations. METHODS We reviewed patients from January 2022 to December 2023 at Asan Medical Center who underwent therapeutic plasma exchange (TPE) due to elevated ABO antibody titers and suspected acute antibody-mediated rejection (AMR) after ABOi-KT. Data collected included pre- and posttransplantation laboratory results, clinical and procedural information, imaging studies, and needle biopsy results of the renal graft. RESULTS We encountered 3 cases of acute AMR 2 weeks after transplantation. All cases exhibited simultaneous increases in anti-ABO antibody isoagglutinin titers, creatinine, and C-reactive protein levels. Clinical signs, including fever, suggested possible infection, and renal graft biopsy, confirmed AMR in all cases. Two cases underwent graftectomy, while the third recovered renal function after conservative treatment, including TPE. CONCLUSIONS Our findings suggest that a 2-week monitoring period for isoagglutinin titers after ABOi-KT may not be sufficient to detect late AMR. Extending the monitoring duration and considering lifelong fresh-frozen plasma transfusion with graft-compatible blood types, along with periodic isoagglutinin titer testing in cases of suspected AMR, may improve long-term graft outcomes.
ABO 血型不相容肾移植后的长期异凝集素监测。
目的 本研究旨在评估ABO血型不相容肾移植(ABOi-KT)后每天进行为期两周的异凝集素滴度检测是否足以确保成功移植,并主张在特定情况下延长监测时间。方法 我们回顾了牙山医疗中心2022年1月至2023年12月期间因ABO抗体滴度升高和ABOi-KT后疑似急性抗体介导的排斥反应(AMR)而接受治疗性血浆置换(TPE)的患者。收集的数据包括移植前后的实验室结果、临床和手术信息、影像学检查和肾移植针活检结果。所有病例的抗逆转录病毒抗体等凝集素滴度、肌酐和 C 反应蛋白水平均同时升高。包括发热在内的临床症状提示可能发生了感染,肾移植活检证实所有病例都发生了急性AMR。结论我们的研究结果表明,ABOi-KT 后 2 周的异凝集素滴度监测期可能不足以发现晚期 AMR。延长监测时间并考虑终身输注与移植物血型相容的新鲜冷冻血浆,同时在疑似 AMR 的病例中定期检测异凝集素滴度,可能会改善移植物的长期预后。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信