{"title":"Long-term isoagglutinin monitoring after ABO-incompatible kidney transplantation.","authors":"Han Joo Kim,Yousun Chung,Hyungsuk Kim,Youngmin Ko,Young Hoon Kim,Sang-Hyun Hwang,Heung-Bum Oh,Dae-Hyun Ko","doi":"10.1093/ajcp/aqae122","DOIUrl":null,"url":null,"abstract":"OBJECTIVES\r\nThis study aimed to evaluate whether a 2-week period of daily isoagglutinin titer testing after ABO-incompatible kidney transplantation (ABOi-KT) is sufficient to ensure successful engraftment and to advocate for an extension of the monitoring duration in specific situations.\r\n\r\nMETHODS\r\nWe reviewed patients from January 2022 to December 2023 at Asan Medical Center who underwent therapeutic plasma exchange (TPE) due to elevated ABO antibody titers and suspected acute antibody-mediated rejection (AMR) after ABOi-KT. Data collected included pre- and posttransplantation laboratory results, clinical and procedural information, imaging studies, and needle biopsy results of the renal graft.\r\n\r\nRESULTS\r\nWe encountered 3 cases of acute AMR 2 weeks after transplantation. All cases exhibited simultaneous increases in anti-ABO antibody isoagglutinin titers, creatinine, and C-reactive protein levels. Clinical signs, including fever, suggested possible infection, and renal graft biopsy, confirmed AMR in all cases. Two cases underwent graftectomy, while the third recovered renal function after conservative treatment, including TPE.\r\n\r\nCONCLUSIONS\r\nOur findings suggest that a 2-week monitoring period for isoagglutinin titers after ABOi-KT may not be sufficient to detect late AMR. Extending the monitoring duration and considering lifelong fresh-frozen plasma transfusion with graft-compatible blood types, along with periodic isoagglutinin titer testing in cases of suspected AMR, may improve long-term graft outcomes.","PeriodicalId":7506,"journal":{"name":"American journal of clinical pathology","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of clinical pathology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ajcp/aqae122","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PATHOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
OBJECTIVES
This study aimed to evaluate whether a 2-week period of daily isoagglutinin titer testing after ABO-incompatible kidney transplantation (ABOi-KT) is sufficient to ensure successful engraftment and to advocate for an extension of the monitoring duration in specific situations.
METHODS
We reviewed patients from January 2022 to December 2023 at Asan Medical Center who underwent therapeutic plasma exchange (TPE) due to elevated ABO antibody titers and suspected acute antibody-mediated rejection (AMR) after ABOi-KT. Data collected included pre- and posttransplantation laboratory results, clinical and procedural information, imaging studies, and needle biopsy results of the renal graft.
RESULTS
We encountered 3 cases of acute AMR 2 weeks after transplantation. All cases exhibited simultaneous increases in anti-ABO antibody isoagglutinin titers, creatinine, and C-reactive protein levels. Clinical signs, including fever, suggested possible infection, and renal graft biopsy, confirmed AMR in all cases. Two cases underwent graftectomy, while the third recovered renal function after conservative treatment, including TPE.
CONCLUSIONS
Our findings suggest that a 2-week monitoring period for isoagglutinin titers after ABOi-KT may not be sufficient to detect late AMR. Extending the monitoring duration and considering lifelong fresh-frozen plasma transfusion with graft-compatible blood types, along with periodic isoagglutinin titer testing in cases of suspected AMR, may improve long-term graft outcomes.
期刊介绍:
The American Journal of Clinical Pathology (AJCP) is the official journal of the American Society for Clinical Pathology and the Academy of Clinical Laboratory Physicians and Scientists. It is a leading international journal for publication of articles concerning novel anatomic pathology and laboratory medicine observations on human disease. AJCP emphasizes articles that focus on the application of evolving technologies for the diagnosis and characterization of diseases and conditions, as well as those that have a direct link toward improving patient care.