Influence of the Electrical Test Setup on the Voltage Gain Measurement of an Unloaded Rosen-Type Piezoelectric Transformer Vibrating in the First Three Modes

IF 1 4区 工程技术 Q4 INSTRUMENTS & INSTRUMENTATION
Faiza Boukazouha, Hamza Barkat, Abdesselam Rouabha, Abderahim Herbadji, Mohamed Rguiti
{"title":"Influence of the Electrical Test Setup on the Voltage Gain Measurement of an Unloaded Rosen-Type Piezoelectric Transformer Vibrating in the First Three Modes","authors":"Faiza Boukazouha, Hamza Barkat, Abdesselam Rouabha, Abderahim Herbadji, Mohamed Rguiti","doi":"10.2478/msr-2024-0019","DOIUrl":null,"url":null,"abstract":"In recent years, Piezoelectric Transformers (PTs) have become a great success due to their excellent properties, especially in applications requiring high voltage. The Rosen-type PT is well known for this performance, as its voltage gain at the resonant frequency can reach few thousands. However, the high output impedance of this device can make an accurate electrical measurement of the output voltage difficult, hence the need to ensure good impedance matching along the measuring electrical test setup. For this purpose, two high impedance oscilloscope probes were successively added to the secondary side to further emulate the measurement chain and match the experiments as closely as possible with the developed 1D model. Accordingly, for an unloaded Rosen type piezoelectric transformer, made of hard ceramic (pz26) with corresponding dimensions 2L×w×t =25 mm×3 mm×2 mm and operating in the first three modes, the corresponding input impedances Zin were evaluated at 665 Ω - 225 Ω and 1974 Ω, while the output impedances Zout were evaluated at 19.2 MΩ - 15.4 MΩ, and 1.8 MΩ. A voltage gain of 164, 179 and 23 at frequencies of 69.4 kHz, 136 kHz and 204.6 kHz, respectively was successfully measured, with a precision of less than 5%. In addition, a detailed equivalent circuit of the transformer was built and all its lumped RLC components were experimentally identified using the Nyquist diagram showing, on the whole, a well-accepted agreement with the expected results.","PeriodicalId":49848,"journal":{"name":"Measurement Science Review","volume":"9 1","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement Science Review","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2478/msr-2024-0019","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

In recent years, Piezoelectric Transformers (PTs) have become a great success due to their excellent properties, especially in applications requiring high voltage. The Rosen-type PT is well known for this performance, as its voltage gain at the resonant frequency can reach few thousands. However, the high output impedance of this device can make an accurate electrical measurement of the output voltage difficult, hence the need to ensure good impedance matching along the measuring electrical test setup. For this purpose, two high impedance oscilloscope probes were successively added to the secondary side to further emulate the measurement chain and match the experiments as closely as possible with the developed 1D model. Accordingly, for an unloaded Rosen type piezoelectric transformer, made of hard ceramic (pz26) with corresponding dimensions 2L×w×t =25 mm×3 mm×2 mm and operating in the first three modes, the corresponding input impedances Zin were evaluated at 665 Ω - 225 Ω and 1974 Ω, while the output impedances Zout were evaluated at 19.2 MΩ - 15.4 MΩ, and 1.8 MΩ. A voltage gain of 164, 179 and 23 at frequencies of 69.4 kHz, 136 kHz and 204.6 kHz, respectively was successfully measured, with a precision of less than 5%. In addition, a detailed equivalent circuit of the transformer was built and all its lumped RLC components were experimentally identified using the Nyquist diagram showing, on the whole, a well-accepted agreement with the expected results.
电气测试装置对以前三模振动的无负载罗森型压电变压器电压增益测量的影响
近年来,压电变压器(PT)因其卓越的性能而大获成功,尤其是在需要高电压的应用中。罗森型压电变压器因其共振频率下的电压增益高达数千而闻名于世。然而,这种装置的高输出阻抗会给输出电压的精确电气测量带来困难,因此需要确保测量电气测试装置具有良好的阻抗匹配。为此,我们在二次侧相继添加了两个高阻抗示波器探头,以进一步模拟测量链,并尽可能使实验与所开发的一维模型相匹配。因此,对于由硬陶瓷(pz26)制成、相应尺寸为 2L×w×t =25 mm×3 mm×2 mm 的无负载罗森型压电变压器,在前三种模式下工作时,相应的输入阻抗 Zin 分别为 665 Ω - 225 Ω 和 1974 Ω,而输出阻抗 Zout 分别为 19.2 MΩ - 15.4 MΩ 和 1.8 MΩ。成功测得频率分别为 69.4 kHz、136 kHz 和 204.6 kHz 时的电压增益分别为 164、179 和 23,精度小于 5%。此外,还建立了变压器的详细等效电路,并利用奈奎斯特图对其所有块状 RLC 元件进行了实验鉴定,结果显示,总体上与预期结果完全一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Measurement Science Review
Measurement Science Review INSTRUMENTS & INSTRUMENTATION-
CiteScore
2.00
自引率
11.10%
发文量
37
审稿时长
4.8 months
期刊介绍: - theory of measurement - mathematical processing of measured data - measurement uncertainty minimisation - statistical methods in data evaluation and modelling - measurement as an interdisciplinary activity - measurement science in education - medical imaging methods, image processing - biosignal measurement, processing and analysis - model based biomeasurements - neural networks in biomeasurement - telemeasurement in biomedicine - measurement in nanomedicine - measurement of basic physical quantities - magnetic and electric fields measurements - measurement of geometrical and mechanical quantities - optical measuring methods - electromagnetic compatibility - measurement in material science
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信