Clinical outcomes after implantation of a novel binocular complementary extended depth of focus intraocular lens compared to bilateral low near-add multifocal intraocular lenses.
{"title":"Clinical outcomes after implantation of a novel binocular complementary extended depth of focus intraocular lens compared to bilateral low near-add multifocal intraocular lenses.","authors":"Hannah Ivellio-Vellin,Manuel Ruiss,Julius Hienert,Stefan Georgiev,Caroline Pilwachs,Andreea Fisus,Oliver Findl","doi":"10.1159/000541308","DOIUrl":null,"url":null,"abstract":"INTRODUCTION\r\nAim of this study was to assess the clinical outcomes of two diffractive intraocular lenses (IOL): a novel binocular complementary IOL compared to a conventional low near-add multifocal IOL (MIOL).\r\n\r\nMETHODS\r\nPatients scheduled for cataract surgery were randomly allocated into two groups receiving either binocular complementary optical systems (ARTIS SYMBIOSE Mid and Plus, Cristalens, France) or low near-add MIOL (AT LARA, Carl Zeiss Meditec AG, Germany). Patients had visual acuity (VA) assessment at distance, intermediate, and near as well as evaluation of contrast sensitivity, halometry and reading performance.\r\n\r\nRESULTS\r\nIn total, 56 eyes of 28 patients were enrolled. At 6 months, there were no statistically significant differences in visual acuity between the ARTIS SYMBIOSE and the AT LARA. Contrast sensitivity at 1.5 cycles per degree under photopic conditions without glare was 1.54 logCS with the ARTIS SYMBIOSE and 1.43 logCS with the AT LARA (p=0.046), under mesopic conditions with glare at 1.5 and 3 cycles per degree 1.31 logCS and 1.28 logCS with the ARTIS SYMBIOSE, respectively, compared to 0.58 logCS and 0.51 logCS with the AT LARA (p=0.002; p=0.006). Halos and reading performance between both groups were similar.\r\n\r\nCONCLUSION\r\nThere were no significant differences between both groups in visual acuity at different distances, reading ability or halometry. The contrast sensitivity at low spatial frequencies was better in the ARTIS SYMBIOSE group under photopic conditions with and without glare as well as mesopic conditions with glare.","PeriodicalId":19662,"journal":{"name":"Ophthalmic Research","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000541308","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
INTRODUCTION
Aim of this study was to assess the clinical outcomes of two diffractive intraocular lenses (IOL): a novel binocular complementary IOL compared to a conventional low near-add multifocal IOL (MIOL).
METHODS
Patients scheduled for cataract surgery were randomly allocated into two groups receiving either binocular complementary optical systems (ARTIS SYMBIOSE Mid and Plus, Cristalens, France) or low near-add MIOL (AT LARA, Carl Zeiss Meditec AG, Germany). Patients had visual acuity (VA) assessment at distance, intermediate, and near as well as evaluation of contrast sensitivity, halometry and reading performance.
RESULTS
In total, 56 eyes of 28 patients were enrolled. At 6 months, there were no statistically significant differences in visual acuity between the ARTIS SYMBIOSE and the AT LARA. Contrast sensitivity at 1.5 cycles per degree under photopic conditions without glare was 1.54 logCS with the ARTIS SYMBIOSE and 1.43 logCS with the AT LARA (p=0.046), under mesopic conditions with glare at 1.5 and 3 cycles per degree 1.31 logCS and 1.28 logCS with the ARTIS SYMBIOSE, respectively, compared to 0.58 logCS and 0.51 logCS with the AT LARA (p=0.002; p=0.006). Halos and reading performance between both groups were similar.
CONCLUSION
There were no significant differences between both groups in visual acuity at different distances, reading ability or halometry. The contrast sensitivity at low spatial frequencies was better in the ARTIS SYMBIOSE group under photopic conditions with and without glare as well as mesopic conditions with glare.
期刊介绍:
''Ophthalmic Research'' features original papers and reviews reporting on translational and clinical studies. Authors from throughout the world cover research topics on every field in connection with physical, physiologic, pharmacological, biochemical and molecular biological aspects of ophthalmology. This journal also aims to provide a record of international clinical research for both researchers and clinicians in ophthalmology. Finally, the transfer of information from fundamental research to clinical research and clinical practice is particularly welcome.