Bioanalytical Method for Estimation of Nitrofurantoin in Human Plasma Using Liquid Chromatography–Tandem Mass Spectrometry

IF 1 4区 化学 Q4 CHEMISTRY, ANALYTICAL
Ganesan Padmini Tamilarasi, Krishnan Manikandan, Viswas Raja Solomon
{"title":"Bioanalytical Method for Estimation of Nitrofurantoin in Human Plasma Using Liquid Chromatography–Tandem Mass Spectrometry","authors":"Ganesan Padmini Tamilarasi,&nbsp;Krishnan Manikandan,&nbsp;Viswas Raja Solomon","doi":"10.1134/S1061934824700497","DOIUrl":null,"url":null,"abstract":"<p>An ultra-performance liquid chromatography-tandem mass spectrometry method for estimating nitrofurantoin in K<sub>2</sub>EDTA human plasma has been developed using the liquid-liquid extraction technique. This method used electrospray ionization in negative mode for nitrofurantoin using triple quadruple mass spectrometry, with nitrofurantoin-<sup>13</sup>C<sub>3</sub> employed as an internal standard. Nitrofurantoin was extracted via the liquid-liquid extraction method and separated on an analytical column Xbridge C18 (4.6 × 100 mm, 3.5 μm). Nitrofurantoin and nitrofurantoin-<sup>13</sup>C<sub>3</sub> were performed using multiple-reaction monitoring acquisition modes with the transition of <i>m</i>/<i>z</i> from 237.06 to 152.05 (nitrofurantoin) and from 240.04 to 152.04 (nitrofurantoin-<sup>13</sup>C<sub>3</sub>). The linearity range for nitrofurantoin was optimized from 5 to 800 ng/mL, respectively. The average recovery of nitrofurantoin and nitrofurantoin-<sup>13</sup>C<sub>3</sub> was 82.9 and 93.8%, respectively. The inter-precision ranged from 2.5 to 5.5%, and the inter-run accuracy range (deviation) ranged from –0.5 to 3.6% across quality control levels. The method was validated following USFDA guidelines and was determined to be straightforward, highly sensitive, precise, robust, and accurate. Therefore, it is suitable for routine quantification of nitrofurantoin in bulk drug and formulation.</p>","PeriodicalId":606,"journal":{"name":"Journal of Analytical Chemistry","volume":"79 8","pages":"1108 - 1120"},"PeriodicalIF":1.0000,"publicationDate":"2024-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1134/S1061934824700497","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

An ultra-performance liquid chromatography-tandem mass spectrometry method for estimating nitrofurantoin in K2EDTA human plasma has been developed using the liquid-liquid extraction technique. This method used electrospray ionization in negative mode for nitrofurantoin using triple quadruple mass spectrometry, with nitrofurantoin-13C3 employed as an internal standard. Nitrofurantoin was extracted via the liquid-liquid extraction method and separated on an analytical column Xbridge C18 (4.6 × 100 mm, 3.5 μm). Nitrofurantoin and nitrofurantoin-13C3 were performed using multiple-reaction monitoring acquisition modes with the transition of m/z from 237.06 to 152.05 (nitrofurantoin) and from 240.04 to 152.04 (nitrofurantoin-13C3). The linearity range for nitrofurantoin was optimized from 5 to 800 ng/mL, respectively. The average recovery of nitrofurantoin and nitrofurantoin-13C3 was 82.9 and 93.8%, respectively. The inter-precision ranged from 2.5 to 5.5%, and the inter-run accuracy range (deviation) ranged from –0.5 to 3.6% across quality control levels. The method was validated following USFDA guidelines and was determined to be straightforward, highly sensitive, precise, robust, and accurate. Therefore, it is suitable for routine quantification of nitrofurantoin in bulk drug and formulation.

Abstract Image

Abstract Image

利用液相色谱-串联质谱法估算人体血浆中硝基呋喃妥因的生物分析方法
摘要 采用液-液萃取技术,建立了一种超高效液相色谱-串联质谱法测定K2EDTA人体血浆中硝基呋喃妥因的方法。该方法采用电喷雾负离子模式,以硝基呋喃妥因-13C3为内标物,采用三重四极杆质谱检测硝基呋喃妥因。硝基呋喃妥因采用液液萃取法提取,并在分析柱 Xbridge C18(4.6 × 100 mm,3.5 μm)上分离。硝基呋喃妥因和硝基呋喃妥因-13C3 采用多反应监测采集模式,m/z 在 237.06 至 152.05(硝基呋喃妥因)和 240.04 至 152.04(硝基呋喃妥因-13C3)之间转换。硝基呋喃妥因的线性范围分别优化为 5 至 800 ng/mL。硝基呋喃妥因和硝基呋喃妥因-13C3 的平均回收率分别为 82.9% 和 93.8%。在不同的质控水平下,精确度范围为2.5%至5.5%,准确度范围(偏差)为-0.5%至3.6%。该方法按照美国食品药品管理局的指导原则进行了验证,结果表明该方法简便、灵敏度高、精确、稳健、准确。因此,该方法适用于散装药物和制剂中硝基呋喃妥因的常规定量分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Analytical Chemistry
Journal of Analytical Chemistry 化学-分析化学
CiteScore
2.10
自引率
9.10%
发文量
146
审稿时长
13 months
期刊介绍: The Journal of Analytical Chemistry is an international peer reviewed journal that covers theoretical and applied aspects of analytical chemistry; it informs the reader about new achievements in analytical methods, instruments and reagents. Ample space is devoted to problems arising in the analysis of vital media such as water and air. Consideration is given to the detection and determination of metal ions, anions, and various organic substances. The journal welcomes manuscripts from all countries in the English or Russian language.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信