IFN-γ and IL-10 Immunosensor with Vertically Aligned Carbon Nanotube Interdigitated Electrodes toward Pen-Side Cattle Paratuberculosis Monitoring

IF 4.4 4区 综合性期刊 Q1 MULTIDISCIPLINARY SCIENCES
Shaowei Ding, Benjamin J. Brownlee, Kshama Parate, Cicero C. Pola, Bolin Chen, Jesse M. Hostetter, Douglas Jones, John Jackman, Brian D. Iverson, Jonathan C. Claussen
{"title":"IFN-γ and IL-10 Immunosensor with Vertically Aligned Carbon Nanotube Interdigitated Electrodes toward Pen-Side Cattle Paratuberculosis Monitoring","authors":"Shaowei Ding,&nbsp;Benjamin J. Brownlee,&nbsp;Kshama Parate,&nbsp;Cicero C. Pola,&nbsp;Bolin Chen,&nbsp;Jesse M. Hostetter,&nbsp;Douglas Jones,&nbsp;John Jackman,&nbsp;Brian D. Iverson,&nbsp;Jonathan C. Claussen","doi":"10.1002/gch2.202400021","DOIUrl":null,"url":null,"abstract":"<p>Highly sensitive vertically aligned carbon nanotube arrays (VANTAs) interdigitated electrode (IDE) arrays are developed for electrochemical biosensing of two cytokines (i.e., interleukin-10 (IL-10) and interferon-gamma (IFN-γ)) that are useful for early detection Johne's disease (Bovine Paratuberculosis) in cattle. The high aspect ratio VANTA-IDEs (50–60 µm in height) are grown through a chemical vapor deposition process from an iron (Fe) catalyst that is lithographically patterned on a silicon wafer with equal finger width and inter-finger spacing of 25 µm. After functionalization with distinct antibodies the VANTA-IDEs are capable of selective detection of both IL-10 and IFN-γ within an actual biological matrix (i.e., diluted bovine implant supernatant) over concentration ranges of 0.1 to 30 pg mL<sup>−1</sup> (limit of detection – LOD: 0.0911 pg mL<sup>−1</sup>) and 50–500 pg mL<sup>−1</sup> (LOD: 24.17 pg mL<sup>−1</sup>), respectively with a response time of &lt;35 min. Results demonstrate important initial steps for rapid, pen-side identification of cattle with stage-I <i>Mycobacterium avium</i> subspecies <i>paratuberculosis</i> infection before physical symptoms of Johne's disease are present. Such a rapid pen-side diagnostic test can be used on cattle at an auction or before they are introduced to a herd to ensure the larger population does not become infected with Johne's disease.</p>","PeriodicalId":12646,"journal":{"name":"Global Challenges","volume":"8 9","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/gch2.202400021","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global Challenges","FirstCategoryId":"103","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/gch2.202400021","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Highly sensitive vertically aligned carbon nanotube arrays (VANTAs) interdigitated electrode (IDE) arrays are developed for electrochemical biosensing of two cytokines (i.e., interleukin-10 (IL-10) and interferon-gamma (IFN-γ)) that are useful for early detection Johne's disease (Bovine Paratuberculosis) in cattle. The high aspect ratio VANTA-IDEs (50–60 µm in height) are grown through a chemical vapor deposition process from an iron (Fe) catalyst that is lithographically patterned on a silicon wafer with equal finger width and inter-finger spacing of 25 µm. After functionalization with distinct antibodies the VANTA-IDEs are capable of selective detection of both IL-10 and IFN-γ within an actual biological matrix (i.e., diluted bovine implant supernatant) over concentration ranges of 0.1 to 30 pg mL−1 (limit of detection – LOD: 0.0911 pg mL−1) and 50–500 pg mL−1 (LOD: 24.17 pg mL−1), respectively with a response time of <35 min. Results demonstrate important initial steps for rapid, pen-side identification of cattle with stage-I Mycobacterium avium subspecies paratuberculosis infection before physical symptoms of Johne's disease are present. Such a rapid pen-side diagnostic test can be used on cattle at an auction or before they are introduced to a herd to ensure the larger population does not become infected with Johne's disease.

Abstract Image

采用垂直排列碳纳米管交错电极的 IFN-γ 和 IL-10 免疫传感器,用于笔边牛副结核病监测
我们开发了高灵敏度垂直排列碳纳米管阵列(VANTAs)交错电极(IDE)阵列,用于对两种细胞因子(即白细胞介素-10(IL-10)和干扰素-γ(IFN-γ))进行电化学生物传感,这两种细胞因子可用于牛约翰氏病(牛副结核病)的早期检测。高纵横比 VANTA-IDEs(高度为 50-60 微米)是通过化学气相沉积工艺从铁(Fe)催化剂中生长出来的,该催化剂在硅晶片上进行光刻图案,指宽相等,指间距为 25 微米。用不同的抗体进行功能化后,VANTA-IDEs 能够在实际生物基质(即稀释的牛植入物上清液)中选择性地检测 IL-10 和 IFN-γ,检测浓度范围分别为 0.1 至 30 pg mL-1(检测限:0.0911 pg mL-1)和 50 至 500 pg mL-1(检测限:24.17 pg mL-1),响应时间为 35 分钟。结果表明,在出现约翰氏病的身体症状之前,在牛栏边快速识别 I 期副结核分枝杆菌感染牛是非常重要的初始步骤。这种栏边快速诊断检测可用于拍卖会上的牛,或在将牛引入牛群之前对其进行检测,以确保更多的牛群不会感染约翰氏病。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Global Challenges
Global Challenges MULTIDISCIPLINARY SCIENCES-
CiteScore
8.70
自引率
0.00%
发文量
79
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信