EANM position paper on challenges and opportunities of full-ring 360° CZT bone imaging: it’s time to let go of planar whole-body bone imaging

IF 8.6 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Richard Graham, David Morland, Sarah Cade, Laetitia Imbert, Emmanouil Panagiotidis, Jens Kurth, Frédéric Paycha, Tim Van den Wyngaert
{"title":"EANM position paper on challenges and opportunities of full-ring 360° CZT bone imaging: it’s time to let go of planar whole-body bone imaging","authors":"Richard Graham, David Morland, Sarah Cade, Laetitia Imbert, Emmanouil Panagiotidis, Jens Kurth, Frédéric Paycha, Tim Van den Wyngaert","doi":"10.1007/s00259-024-06906-4","DOIUrl":null,"url":null,"abstract":"<p>The introduction of smaller footprint, more sensitive Cadmium-Zinc-Telluride (CZT)-based detectors with improved spatial and energy resolution has enabled the design of innovative full-ring 360° CZT SPECT/CT systems (e.g., VERITON<sup>®</sup> and StarGuide™). With this transformative technology now aiming to become mainstream in clinical practice, several critical questions need to be addressed. This EANM position paper provides practical recommendations on how to use these devices for routine bone SPECT/CT studies, facilitating the transition from traditional planar whole-body imaging and conventional SPECT/CT to these novel systems. In particular, initial guidance is provided on imaging acquisition and reporting workflows, image reconstruction, and CT acquisition parameters. Given the emerging nature of this technology, the available evidence base is still limited, and the proposed adaptations in workflows and scan protocols will likely evolve before being integrated into definitive guidelines. In the meantime, this EANM position paper serves as a comprehensive guide for integrating these advanced hybrid SPECT/CT imaging systems into clinical practice and outlining areas for further study.</p>","PeriodicalId":11909,"journal":{"name":"European Journal of Nuclear Medicine and Molecular Imaging","volume":null,"pages":null},"PeriodicalIF":8.6000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Nuclear Medicine and Molecular Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00259-024-06906-4","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

The introduction of smaller footprint, more sensitive Cadmium-Zinc-Telluride (CZT)-based detectors with improved spatial and energy resolution has enabled the design of innovative full-ring 360° CZT SPECT/CT systems (e.g., VERITON® and StarGuide™). With this transformative technology now aiming to become mainstream in clinical practice, several critical questions need to be addressed. This EANM position paper provides practical recommendations on how to use these devices for routine bone SPECT/CT studies, facilitating the transition from traditional planar whole-body imaging and conventional SPECT/CT to these novel systems. In particular, initial guidance is provided on imaging acquisition and reporting workflows, image reconstruction, and CT acquisition parameters. Given the emerging nature of this technology, the available evidence base is still limited, and the proposed adaptations in workflows and scan protocols will likely evolve before being integrated into definitive guidelines. In the meantime, this EANM position paper serves as a comprehensive guide for integrating these advanced hybrid SPECT/CT imaging systems into clinical practice and outlining areas for further study.

Abstract Image

关于全环 360° CZT 骨成像的挑战与机遇的 EANM 立场文件:是时候放弃平面全身骨成像了
基于镉锌碲化镉(CZT)的探测器体积更小、灵敏度更高、空间分辨率和能量分辨率都得到了提高,因此能够设计出创新的全环 360° CZT SPECT/CT 系统(如 VERITON® 和 StarGuide™)。随着这项变革性技术成为临床实践的主流,有几个关键问题亟待解决。这篇 EANM 立场文件就如何将这些设备用于常规骨 SPECT/CT 研究提供了实用建议,促进了从传统的平面全身成像和常规 SPECT/CT 向这些新型系统的过渡。特别是在成像采集和报告工作流程、图像重建和 CT 采集参数方面提供了初步指导。鉴于该技术的新兴性质,现有的证据基础仍然有限,建议的工作流程和扫描方案调整很可能会在纳入明确的指南之前不断发展。与此同时,这份 EANM 立场文件可作为将这些先进的混合 SPECT/CT 成像系统融入临床实践的全面指南,并概述了有待进一步研究的领域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
15.60
自引率
9.90%
发文量
392
审稿时长
3 months
期刊介绍: The European Journal of Nuclear Medicine and Molecular Imaging serves as a platform for the exchange of clinical and scientific information within nuclear medicine and related professions. It welcomes international submissions from professionals involved in the functional, metabolic, and molecular investigation of diseases. The journal's coverage spans physics, dosimetry, radiation biology, radiochemistry, and pharmacy, providing high-quality peer review by experts in the field. Known for highly cited and downloaded articles, it ensures global visibility for research work and is part of the EJNMMI journal family.
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信