Stereotactic body radiotherapy using CyberKnife versus interstitial brachytherapy in accelerated partial breast irradiation on left-sided breast: A comparison of dosimetric characteristics and preliminary clinical results

IF 5.7 2区 医学 Q1 OBSTETRICS & GYNECOLOGY
Ting-Na Wei , Jia-Fu Lin , Mei-Chun Cheng , Hui-Ling Yeh
{"title":"Stereotactic body radiotherapy using CyberKnife versus interstitial brachytherapy in accelerated partial breast irradiation on left-sided breast: A comparison of dosimetric characteristics and preliminary clinical results","authors":"Ting-Na Wei ,&nbsp;Jia-Fu Lin ,&nbsp;Mei-Chun Cheng ,&nbsp;Hui-Ling Yeh","doi":"10.1016/j.breast.2024.103796","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>We compared the dosimetric characteristics of the target and organs at risk (OARs) as well as the preliminary clinical outcomes between two accelerated partial breast irradiation (APBI) techniques.</p></div><div><h3>Methods</h3><p>Forty-four patients diagnosed with left-sided early breast cancer who underwent APBI using either interstitial brachytherapy (IB) or stereotactic body radiation therapy (SBRT) with CyberKnife (CK) were retrospectively reviewed. The dosimetric parameters of the target and OARs were compared. Preliminary clinical outcomes, including tumor control and acute toxicity, were analyzed.</p></div><div><h3>Results</h3><p>Treatment plans with CK demonstrated a better cardiac dose-sparing effect. Radiation doses to the heart at V<sub>150cGy</sub> for the CK and IB groups were 24.4 % and 60.4 %, respectively (<em>p</em> &lt; 0.001), while the mean heart doses for the CK and IB groups were 107.4 cGy and 204 cGy, respectively (<em>p</em> &lt; 0.001). The heart D<sub>1c.c.</sub> and the ipsilateral lung received a lower dose in the IB group, without any significant differences. The median follow-up time in the CK and IB groups was 28.6 and 61.3 months, respectively. No patients died from either breast cancer or cardiac events during follow-up. A locoregional recurrence event at the neck occurred in one patient within the IB group.</p></div><div><h3>Conclusions</h3><p>APBI planned by CK was shown to have a better dose-sparing effect on the heart, as well as better conformity and homogeneity to the target. CK is a non-invasive treatment which showed minimal acute toxicity and promising tumor control.</p></div>","PeriodicalId":9093,"journal":{"name":"Breast","volume":"78 ","pages":"Article 103796"},"PeriodicalIF":5.7000,"publicationDate":"2024-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0960977624001279/pdfft?md5=c187a162a0112bd2369b3e57ba9a8251&pid=1-s2.0-S0960977624001279-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Breast","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0960977624001279","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

We compared the dosimetric characteristics of the target and organs at risk (OARs) as well as the preliminary clinical outcomes between two accelerated partial breast irradiation (APBI) techniques.

Methods

Forty-four patients diagnosed with left-sided early breast cancer who underwent APBI using either interstitial brachytherapy (IB) or stereotactic body radiation therapy (SBRT) with CyberKnife (CK) were retrospectively reviewed. The dosimetric parameters of the target and OARs were compared. Preliminary clinical outcomes, including tumor control and acute toxicity, were analyzed.

Results

Treatment plans with CK demonstrated a better cardiac dose-sparing effect. Radiation doses to the heart at V150cGy for the CK and IB groups were 24.4 % and 60.4 %, respectively (p < 0.001), while the mean heart doses for the CK and IB groups were 107.4 cGy and 204 cGy, respectively (p < 0.001). The heart D1c.c. and the ipsilateral lung received a lower dose in the IB group, without any significant differences. The median follow-up time in the CK and IB groups was 28.6 and 61.3 months, respectively. No patients died from either breast cancer or cardiac events during follow-up. A locoregional recurrence event at the neck occurred in one patient within the IB group.

Conclusions

APBI planned by CK was shown to have a better dose-sparing effect on the heart, as well as better conformity and homogeneity to the target. CK is a non-invasive treatment which showed minimal acute toxicity and promising tumor control.

使用 CyberKnife 的立体定向体放射治疗与间质近距离放射治疗在加速左侧乳房部分照射中的应用:剂量学特征和初步临床结果的比较。
简介:我们比较了两种加速乳腺部分照射(APBI)技术的靶区和风险器官(OAR)的剂量学特征以及初步临床结果:我们比较了两种加速乳腺部分照射(APBI)技术的靶区和危险器官(OARs)的剂量学特征以及初步临床结果:对44例诊断为左侧早期乳腺癌的患者进行了回顾性研究,这些患者接受了间质近距离放射治疗(IB)或使用CyberKnife(CK)的立体定向体放射治疗(SBRT)。比较了靶区和OAR的剂量学参数。对包括肿瘤控制和急性毒性在内的初步临床结果进行了分析:结果:使用CK的治疗方案具有更好的心脏剂量节省效果。CK组和IB组心脏在V150cGy时的辐射剂量分别为24.4%和60.4%(p 1c.c.),IB组同侧肺部接受的剂量较低,但无明显差异。CK组和IB组的中位随访时间分别为28.6个月和61.3个月。随访期间,没有患者死于乳腺癌或心脏事件。IB组中有一名患者颈部局部复发:结论:用CK计划的APBI对心脏有更好的剂量节省效果,对靶点的一致性和均匀性也更好。CK是一种非侵入性治疗方法,急性毒性极低,肿瘤控制效果良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Breast
Breast 医学-妇产科学
CiteScore
8.70
自引率
2.60%
发文量
165
审稿时长
59 days
期刊介绍: The Breast is an international, multidisciplinary journal for researchers and clinicians, which focuses on translational and clinical research for the advancement of breast cancer prevention, diagnosis and treatment of all stages.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信