{"title":"Effect of abnormal placentation on fetal heart function and neonatal outcomes.","authors":"Sukran Dogru, Asli Altinordu Atci, Fatih Akkus, Ali Acar","doi":"10.1002/jcu.23790","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to investigate the fetal modified (mod)-myocardial performance index (MPI) for fetal cardiac function in placenta percreta (PPC) pregnancies with placenta previa (PP) and assess neonatal outcomes.</p><p><strong>Materials and methods: </strong>This study included 104 pregnant women: 52 with PPC and 52 as the control group. Mod-MPI measurements and neonatal outcomes were evaluated in all cases.</p><p><strong>Results: </strong>The PPC group had a significantly lower left ejection time (p = 0.044) and significantly higher mod-MPI (p = 0.001) than the control group. The optimal mod-MPI predictive cut-off value at the neonatal intensive care unit (NICU) admission in the PPC group was 0.53 with 53.8% specificity and 88.5% sensitivity (p = 0.019). The optimal mod-MPI predictive cut-off value at the 5th APGAR score below 7 in the PPC group was 0.55 with a specificity of 67.7% and a sensitivity of 76.2% (p = 0.016).</p><p><strong>Conclusion: </strong>Fetal MPI was higher in pregnant women with PPC compared to the control group. Among the PPC cases, those with MPI above a certain predictive level showed more frequent NICU admissions and lower APGAR scores.</p>","PeriodicalId":15386,"journal":{"name":"Journal of Clinical Ultrasound","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Ultrasound","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jcu.23790","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/6 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This study aimed to investigate the fetal modified (mod)-myocardial performance index (MPI) for fetal cardiac function in placenta percreta (PPC) pregnancies with placenta previa (PP) and assess neonatal outcomes.

Materials and methods: This study included 104 pregnant women: 52 with PPC and 52 as the control group. Mod-MPI measurements and neonatal outcomes were evaluated in all cases.

Results: The PPC group had a significantly lower left ejection time (p = 0.044) and significantly higher mod-MPI (p = 0.001) than the control group. The optimal mod-MPI predictive cut-off value at the neonatal intensive care unit (NICU) admission in the PPC group was 0.53 with 53.8% specificity and 88.5% sensitivity (p = 0.019). The optimal mod-MPI predictive cut-off value at the 5th APGAR score below 7 in the PPC group was 0.55 with a specificity of 67.7% and a sensitivity of 76.2% (p = 0.016).

Conclusion: Fetal MPI was higher in pregnant women with PPC compared to the control group. Among the PPC cases, those with MPI above a certain predictive level showed more frequent NICU admissions and lower APGAR scores.

胎盘异常对胎儿心脏功能和新生儿预后的影响
研究目的本研究旨在探讨胎盘前置(PP)孕妇的胎儿改良(mod)-心肌表现指数(MPI)对胎儿心脏功能的影响,并评估新生儿的预后:本研究包括 104 名孕妇:52 名前置胎盘孕妇和 52 名对照组孕妇。对所有病例的 Mod-MPI 测量结果和新生儿预后进行了评估:结果:与对照组相比,PPC 组的左心射血时间明显较低(p = 0.044),mod-MPI 则明显较高(p = 0.001)。在新生儿重症监护室(NICU)入院时,PPC 组的最佳 mod-MPI 预测临界值为 0.53,特异性为 53.8%,灵敏度为 88.5%(p = 0.019)。PPC组在第5次APGAR评分低于7分时的最佳mod-MPI预测截断值为0.55,特异性为67.7%,灵敏度为76.2%(p = 0.016):结论:与对照组相比,患有多囊卵巢综合征的孕妇胎儿MPI较高。结论:与对照组相比,PPC 孕妇的胎儿 MPI 较高,其中 MPI 高于一定预测水平的孕妇入住新生儿重症监护室的频率更高,APGAR 评分更低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
248
审稿时长
6 months
期刊介绍: The Journal of Clinical Ultrasound (JCU) is an international journal dedicated to the worldwide dissemination of scientific information on diagnostic and therapeutic applications of medical sonography. The scope of the journal includes--but is not limited to--the following areas: sonography of the gastrointestinal tract, genitourinary tract, vascular system, nervous system, head and neck, chest, breast, musculoskeletal system, and other superficial structures; Doppler applications; obstetric and pediatric applications; and interventional sonography. Studies comparing sonography with other imaging modalities are encouraged, as are studies evaluating the economic impact of sonography. Also within the journal''s scope are innovations and improvements in instrumentation and examination techniques and the use of contrast agents. JCU publishes original research articles, case reports, pictorial essays, technical notes, and letters to the editor. The journal is also dedicated to being an educational resource for its readers, through the publication of review articles and various scientific contributions from members of the editorial board and other world-renowned experts in sonography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信