{"title":"Is there a target value for time in tight range for individuals with type 1 diabetes on MDI? Data from masked CGM.","authors":"Takayuki Ohno, Daisuke Tsujino, Rimei Nishimura","doi":"10.1080/17446651.2024.2400487","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Time in Tight Range (TITR), defined as the percentage of time within the glucose range of 70 to 140 mg/dL, is anticipated to be challenging to maintain without causing hypoglycemia, especially in individuals with type 1 diabetes (T1D). This study aimed to investigate the TITR target value in individuals with T1D on multiple daily injections (MDI).</p><p><strong>Methods: </strong>The study included 101 individuals with T1D on MDI aged 15 to 75 who were hospitalized at Jikei University School of Medicine from September 2006 to November 2013 to conduct Continuous Glucose Monitoring (CGM). The cutoff values of TITR for predicting the attainment of GMI < 7.0%, and TBR < 4% were determined using Receiver Operating Characteristic (ROC) curves.</p><p><strong>Results: </strong>The TITR cutoff value was calculated to be 41% (sensitivity 81%, specificity 88%) and 40% (54%,72%) for predicting GMI < 7.0% and TBR < 4%.</p><p><strong>Conclusions: </strong>In individuals with T1D on MDI without devices capable of preventing hypoglycemia, it is recommended to target TITR at 40% to address the risk of increased hypoglycemia sufficiently.</p>","PeriodicalId":12107,"journal":{"name":"Expert Review of Endocrinology & Metabolism","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert Review of Endocrinology & Metabolism","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17446651.2024.2400487","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Time in Tight Range (TITR), defined as the percentage of time within the glucose range of 70 to 140 mg/dL, is anticipated to be challenging to maintain without causing hypoglycemia, especially in individuals with type 1 diabetes (T1D). This study aimed to investigate the TITR target value in individuals with T1D on multiple daily injections (MDI).
Methods: The study included 101 individuals with T1D on MDI aged 15 to 75 who were hospitalized at Jikei University School of Medicine from September 2006 to November 2013 to conduct Continuous Glucose Monitoring (CGM). The cutoff values of TITR for predicting the attainment of GMI < 7.0%, and TBR < 4% were determined using Receiver Operating Characteristic (ROC) curves.
Results: The TITR cutoff value was calculated to be 41% (sensitivity 81%, specificity 88%) and 40% (54%,72%) for predicting GMI < 7.0% and TBR < 4%.
Conclusions: In individuals with T1D on MDI without devices capable of preventing hypoglycemia, it is recommended to target TITR at 40% to address the risk of increased hypoglycemia sufficiently.
期刊介绍:
Implicated in a plethora of regulatory dysfunctions involving growth and development, metabolism, electrolyte balances and reproduction, endocrine disruption is one of the highest priority research topics in the world. As a result, we are now in a position to better detect, characterize and overcome the damage mediated by adverse interaction with the endocrine system. Expert Review of Endocrinology and Metabolism (ISSN 1744-6651), provides extensive coverage of state-of-the-art research and clinical advancements in the field of endocrine control and metabolism, with a focus on screening, prevention, diagnostics, existing and novel therapeutics, as well as related molecular genetics, pathophysiology and epidemiology.