Comparison of 1- and 3-piece directly 3-dimensional printed indirect bonding trays: An in vitro study.

IF 2.7 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Merve Nur Eglenen, Gülden Karabiber
{"title":"Comparison of 1- and 3-piece directly 3-dimensional printed indirect bonding trays: An in vitro study.","authors":"Merve Nur Eglenen, Gülden Karabiber","doi":"10.1016/j.ajodo.2024.07.015","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>This study aimed to compare the transfer accuracy of indirect bonding trays of different thicknesses and numbers of pieces.</p><p><strong>Methods: </strong>Digital indirect bonding was performed on 56 printed resin models, divided into 4 groups with 14 models in each: 1-mm 1-piece tray (OPT), 2-mm OPT, 1-mm 3-piece tray (TPT), and 2-mm TPT. The trays were designed using Appliance Designer (3Shape A/S, Copenhagen, Denmark). Angular (torque, tip, or angulation) and linear (mesiodistal, buccolingual, occlusogingival, or vertical) differences were compared by using open-source GOM Inspect software (GOM GmbH, Braunschweig, Germany).</p><p><strong>Results: </strong>In the buccolingual direction, the 1-mm TPT (0.180 ± 0.041 mm) was significantly more accurate than the 1-mm OPT (0.240 ± 0.032 mm). In the vertical direction, significant differences were seen between the 1-mm and 2-mm OPTs (1-mm OPT: 0.220 ± 0.043 mm; 2-mm OPT: 0.428 ± 0.143 mm; P = 0.003) and between the 1-mm and 2-mm TPTs (1-mm TPT: 0.210 ± 0.072 mm; 2-mm TPT: 0.340 ± 0.062 mm; P = 0.004) in the total region. In the tip angle, significant differences were seen between the 1-mm and 2-mm OPTs and between the 1-mm OPT and TPT. In the torque angle, a significant difference was seen between the 1-mm TPT (2.815°±0.350°)and 2-mmTPT (2.368° ± 0.245°; P = 0.017).</p><p><strong>Conclusions: </strong>Both the thickness and the splitting of the trays impacted the bracket bonding accuracy. The 1-mm trays were more accurate than the 2-mm trays. Despite a few statistically significant differences between the 1-mm OPT and TPT, the 1-mm OPT was recommended for clinical use, considering the designing and placing of the trays.</p>","PeriodicalId":50806,"journal":{"name":"American Journal of Orthodontics and Dentofacial Orthopedics","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Orthodontics and Dentofacial Orthopedics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.ajodo.2024.07.015","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: This study aimed to compare the transfer accuracy of indirect bonding trays of different thicknesses and numbers of pieces.

Methods: Digital indirect bonding was performed on 56 printed resin models, divided into 4 groups with 14 models in each: 1-mm 1-piece tray (OPT), 2-mm OPT, 1-mm 3-piece tray (TPT), and 2-mm TPT. The trays were designed using Appliance Designer (3Shape A/S, Copenhagen, Denmark). Angular (torque, tip, or angulation) and linear (mesiodistal, buccolingual, occlusogingival, or vertical) differences were compared by using open-source GOM Inspect software (GOM GmbH, Braunschweig, Germany).

Results: In the buccolingual direction, the 1-mm TPT (0.180 ± 0.041 mm) was significantly more accurate than the 1-mm OPT (0.240 ± 0.032 mm). In the vertical direction, significant differences were seen between the 1-mm and 2-mm OPTs (1-mm OPT: 0.220 ± 0.043 mm; 2-mm OPT: 0.428 ± 0.143 mm; P = 0.003) and between the 1-mm and 2-mm TPTs (1-mm TPT: 0.210 ± 0.072 mm; 2-mm TPT: 0.340 ± 0.062 mm; P = 0.004) in the total region. In the tip angle, significant differences were seen between the 1-mm and 2-mm OPTs and between the 1-mm OPT and TPT. In the torque angle, a significant difference was seen between the 1-mm TPT (2.815°±0.350°)and 2-mmTPT (2.368° ± 0.245°; P = 0.017).

Conclusions: Both the thickness and the splitting of the trays impacted the bracket bonding accuracy. The 1-mm trays were more accurate than the 2-mm trays. Despite a few statistically significant differences between the 1-mm OPT and TPT, the 1-mm OPT was recommended for clinical use, considering the designing and placing of the trays.

单件式和三件式直接三维打印间接粘接托盘的比较:体外研究
简介:本研究旨在比较不同厚度和片数的间接粘接托盘的转移准确性:本研究旨在比较不同厚度和片数的间接粘接托盘的转移准确性:对 56 个打印的树脂模型进行数字间接粘接,分为 4 组,每组 14 个模型:1 毫米 1 片式托盘(OPT)、2 毫米 OPT、1 毫米 3 片式托盘(TPT)和 2 毫米 TPT。这些托盘是用 Appliance Designer(3Shape A/S,丹麦哥本哈根)设计的。使用开源的 GOM Inspect 软件(GOM GmbH,德国布伦瑞克)比较了角度(扭矩、尖端或角度)和线性(牙周中、颊舌侧、咬合龈或垂直)差异:结果:在颊舌方向,1 毫米 TPT(0.180 ± 0.041 毫米)的精确度明显高于 1 毫米 OPT(0.240 ± 0.032 毫米)。在垂直方向上,1 毫米和 2 毫米 OPT 之间(1 毫米 OPT:0.220 ± 0.043 毫米;2 毫米 OPT:0.428 ± 0.143 毫米;P = 0.003)以及 1 毫米和 2 毫米 TPT 之间(1 毫米 TPT:0.210 ± 0.072 毫米;2 毫米 TPT:0.340 ± 0.062 毫米;P = 0.004)在整个区域存在显著差异。在尖端角方面,1 毫米和 2 毫米 OPT 之间以及 1 毫米 OPT 和 TPT 之间存在显著差异。在扭矩角方面,1 毫米 TPT(2.815°±0.350°)和 2 毫米 TPT(2.368°±0.245°;P = 0.017)之间存在显著差异:托槽的厚度和裂隙都会影响托槽粘接的准确性。1 毫米托槽比 2 毫米托槽更准确。尽管 1 毫米 OPT 和 TPT 在统计学上存在一些显著差异,但考虑到托槽的设计和放置,建议在临床上使用 1 毫米 OPT。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.80
自引率
13.30%
发文量
432
审稿时长
66 days
期刊介绍: Published for more than 100 years, the American Journal of Orthodontics and Dentofacial Orthopedics remains the leading orthodontic resource. It is the official publication of the American Association of Orthodontists, its constituent societies, the American Board of Orthodontics, and the College of Diplomates of the American Board of Orthodontics. Each month its readers have access to original peer-reviewed articles that examine all phases of orthodontic treatment. Illustrated throughout, the publication includes tables, color photographs, and statistical data. Coverage includes successful diagnostic procedures, imaging techniques, bracket and archwire materials, extraction and impaction concerns, orthognathic surgery, TMJ disorders, removable appliances, and adult therapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信