Assessment of the Omius™ cooling headband effectiveness during a 70-min submaximal running effort followed by a 5-km time-trial in hot/humid conditions

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Antoine Jolicoeur Desroches , Fedi Aloui , Thomas A. Deshayes , Eric D.B. Goulet
{"title":"Assessment of the Omius™ cooling headband effectiveness during a 70-min submaximal running effort followed by a 5-km time-trial in hot/humid conditions","authors":"Antoine Jolicoeur Desroches ,&nbsp;Fedi Aloui ,&nbsp;Thomas A. Deshayes ,&nbsp;Eric D.B. Goulet","doi":"10.1016/j.jtherbio.2024.103964","DOIUrl":null,"url":null,"abstract":"<div><p>Exercise performed under hot/humid conditions can hinder endurance performance. The Omius™ headband (OH) is purported to reduce the perception of heat and improve performance. We examined the impact of OH on selected thermal and cardiovascular functions, subjective perceptions and running performance. Using a randomized crossover protocol, 10 trained male athletes (28 ± 4 years) completed two trials (OH and sham headband (SH), 35.0 ± 0.3 °C, 56 ± 3% relative humidity) comprising 70 min of running (60% <span><math><mrow><mover><mi>V</mi><mo>˙</mo></mover></mrow></math></span> O<sub>2max</sub>) followed by a 5-km running time-trial (TT). Heart rate, perceived exertion and whole-body thermal comfort did not significantly differ between conditions during the submaximal running effort and TT. Rectal temperature was higher with OH (0.11 ± 0.16 °C, <em>p</em> = 0.052) than SH prior to the submaximal running effort, however, no significant differences were observed between conditions regarding the changes in rectal temperature from baseline during the submaximal running effort and TT. Forehead temperature was significantly lower with OH than SH during the submaximal running effort, but no significant differences were observed at the end of the TT. Scores of perceived forehead thermal comfort was only significantly lower with OH than SH during the submaximal running effort. TT performance did not significantly differ between OH (19.8 ± 1.2 min) and SH (20.2 ± 1.0 min). In conclusion, OH improves forehead thermal comfort and reduces forehead temperature but not rectal temperature, heart rate and perceived exertion during, nor 5-km TT performance following, 70 min of submaximal running in the heat.</p></div>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"99","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0306456524001827","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Exercise performed under hot/humid conditions can hinder endurance performance. The Omius™ headband (OH) is purported to reduce the perception of heat and improve performance. We examined the impact of OH on selected thermal and cardiovascular functions, subjective perceptions and running performance. Using a randomized crossover protocol, 10 trained male athletes (28 ± 4 years) completed two trials (OH and sham headband (SH), 35.0 ± 0.3 °C, 56 ± 3% relative humidity) comprising 70 min of running (60% V˙ O2max) followed by a 5-km running time-trial (TT). Heart rate, perceived exertion and whole-body thermal comfort did not significantly differ between conditions during the submaximal running effort and TT. Rectal temperature was higher with OH (0.11 ± 0.16 °C, p = 0.052) than SH prior to the submaximal running effort, however, no significant differences were observed between conditions regarding the changes in rectal temperature from baseline during the submaximal running effort and TT. Forehead temperature was significantly lower with OH than SH during the submaximal running effort, but no significant differences were observed at the end of the TT. Scores of perceived forehead thermal comfort was only significantly lower with OH than SH during the submaximal running effort. TT performance did not significantly differ between OH (19.8 ± 1.2 min) and SH (20.2 ± 1.0 min). In conclusion, OH improves forehead thermal comfort and reduces forehead temperature but not rectal temperature, heart rate and perceived exertion during, nor 5-km TT performance following, 70 min of submaximal running in the heat.

在高温/潮湿条件下进行 70 分钟次极限跑步和 5 公里计时赛期间,评估 Omius™ 冷却头带的功效。
在高温/潮湿条件下进行运动会妨碍耐力表现。Omius™头带(OH)据称可以减少热感并提高成绩。我们研究了 Omius™ 头带对特定热感和心血管功能、主观感觉和跑步表现的影响。采用随机交叉方案,10 名训练有素的男性运动员(28 ± 4 岁)完成了两项试验(OH 和假头带(SH),温度 35.0 ± 0.3 °C,相对湿度 56 ± 3%),包括 70 分钟跑步(60% V˙ O2max),然后进行 5 公里跑步计时赛(TT)。在次极限跑步和 TT 条件下,心率、感觉消耗量和全身热舒适度没有显著差异。在亚极限跑之前,OH(0.11 ± 0.16 °C,p = 0.052)的直肠温度高于SH,但在亚极限跑和TT期间,直肠温度与基线相比的变化在不同条件下没有观察到显著差异。在亚极限跑步期间,OH 的前额温度明显低于 SH,但在 TT 结束时未观察到明显差异。在亚极限跑步时,OH 的前额热舒适度评分明显低于 SH。TT成绩在OH(19.8 ± 1.2 分钟)和SH(20.2 ± 1.0 分钟)之间没有明显差异。总之,在高温下进行 70 分钟的次极限跑步时,OH 可改善前额热舒适度并降低前额温度,但不会降低直肠温度、心率和感觉到的消耗,也不会降低 5 公里 TT 成绩。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信