{"title":"Monomer-mediated growth of β-cyclodextrin-based microporous organic network as stationary phase for capillary electrochromatography.","authors":"Zhengzheng Liao, Jinfang Hu, Zhentao Li","doi":"10.1007/s00216-024-05514-3","DOIUrl":null,"url":null,"abstract":"<p><p>CD-MONs (β-cyclodextrin-based microporous organic networks), derived from β-cyclodextrin, possess notable hydrophobic characteristics, a considerable specific surface area, and remarkable stability, rendering them highly advantageous in separation science. This research aimed to investigate the utility of CD-MONs in chromatography separation. Through a monomer-mediated technique, we fabricated an innovative CD-MON modified capillary column for application in open-tubular capillary electrochromatography (OT-CEC). The CD-MON-based stationary phase on the capillary's inner surface was analyzed using Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). We assessed the performance of the CD-MON modified capillary column for separation purposes. The microstructure and pronounced hydrophobicity of CD-MON contributed to enhanced selectivity and resolution in separating diverse hydrophobic analytes, such as alkylbenzenes, halogenated benzenes, parabens, and polycyclic aromatic hydrocarbons (PAHs). The maximum column efficiency achieved was 1.5 × 10<sup>5</sup> N/m. Additionally, the CD-MON modified capillary column demonstrated notably high column capacity, with a methylbenzene mass loading capacity of up to 197.9 pmol, surpassing that of previously reported porous-material-based capillaries. Furthermore, this self-constructed column was effectively utilized for PAHs determination in actual environmental water samples, exhibiting spiked recoveries ranging from 93.2 to 107.9% in lake water samples. These findings underscore the potential of CD-MON as an effective stationary phase in separation science.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-024-05514-3","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
CD-MONs (β-cyclodextrin-based microporous organic networks), derived from β-cyclodextrin, possess notable hydrophobic characteristics, a considerable specific surface area, and remarkable stability, rendering them highly advantageous in separation science. This research aimed to investigate the utility of CD-MONs in chromatography separation. Through a monomer-mediated technique, we fabricated an innovative CD-MON modified capillary column for application in open-tubular capillary electrochromatography (OT-CEC). The CD-MON-based stationary phase on the capillary's inner surface was analyzed using Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). We assessed the performance of the CD-MON modified capillary column for separation purposes. The microstructure and pronounced hydrophobicity of CD-MON contributed to enhanced selectivity and resolution in separating diverse hydrophobic analytes, such as alkylbenzenes, halogenated benzenes, parabens, and polycyclic aromatic hydrocarbons (PAHs). The maximum column efficiency achieved was 1.5 × 105 N/m. Additionally, the CD-MON modified capillary column demonstrated notably high column capacity, with a methylbenzene mass loading capacity of up to 197.9 pmol, surpassing that of previously reported porous-material-based capillaries. Furthermore, this self-constructed column was effectively utilized for PAHs determination in actual environmental water samples, exhibiting spiked recoveries ranging from 93.2 to 107.9% in lake water samples. These findings underscore the potential of CD-MON as an effective stationary phase in separation science.
期刊介绍:
Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.