A Novel Next-Generation Sequencing Assay for the Identification of BCR::ABL1 Transcript Type and Accurate and Sensitive Detection of TKI-Resistant Mutations.
Zhenyu Yan, Lin Shi, Wei Li, Weihua Liu, Chad Galderisi, Cynthia Spittle, Jin Li
{"title":"A Novel Next-Generation Sequencing Assay for the Identification of BCR::ABL1 Transcript Type and Accurate and Sensitive Detection of TKI-Resistant Mutations.","authors":"Zhenyu Yan, Lin Shi, Wei Li, Weihua Liu, Chad Galderisi, Cynthia Spittle, Jin Li","doi":"10.1093/jalm/jfae096","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The clinical management of chronic myeloid leukemia (CML) patients requires the identification of the type of BCR::ABL1 transcript at diagnosis and the monitoring of its expression and potential tyrosine kinase inhibitor (TKI) resistance mutations during treatment. Detection of resistant mutation requires transcript type-specific amplification of BCR::ABL1 from RNA.</p><p><strong>Methods: </strong>In this study, a custom RNA-based next-generation sequencing (NGS) assay (Dup-Seq BCR::ABL1) that enables (a) the identification of BCR::ABL1 transcript type and (b) the detection of resistance mutations from common and atypical BCR::ABL1 transcript types was developed and validated. The assay design covers BCR exon 1 to ABL1 exon 10 and employs duplicate PCR amplification for error correction. The custom data analysis pipeline enables breakpoint determination and overlapped mutation calling from duplicates, which minimizes the low-level mutation artifacts.</p><p><strong>Results: </strong>This study demonstrates that this novel assay achieves high accuracy (positive percent agreement (PPA) for fusion: 98.5%; PPA and negative percent agreement (NPA) for mutation at 97.8% and 100.0%, respectively) and sensitivity (limit of detection (LOD) for mutation detection at 3% from 10 000 copies of BCR::ABL1 input).</p><p><strong>Conclusions: </strong>The Dup-Seq BCR::ABL1 assay not only allows for the identification of BCR::ABL1 typical and atypical transcript types and accurate and sensitive detection of TKI-resistant mutations but also simplifies molecular testing work flow for the clinical management of CML patients.</p>","PeriodicalId":46361,"journal":{"name":"Journal of Applied Laboratory Medicine","volume":" ","pages":"886-900"},"PeriodicalIF":1.8000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jalm/jfae096","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The clinical management of chronic myeloid leukemia (CML) patients requires the identification of the type of BCR::ABL1 transcript at diagnosis and the monitoring of its expression and potential tyrosine kinase inhibitor (TKI) resistance mutations during treatment. Detection of resistant mutation requires transcript type-specific amplification of BCR::ABL1 from RNA.
Methods: In this study, a custom RNA-based next-generation sequencing (NGS) assay (Dup-Seq BCR::ABL1) that enables (a) the identification of BCR::ABL1 transcript type and (b) the detection of resistance mutations from common and atypical BCR::ABL1 transcript types was developed and validated. The assay design covers BCR exon 1 to ABL1 exon 10 and employs duplicate PCR amplification for error correction. The custom data analysis pipeline enables breakpoint determination and overlapped mutation calling from duplicates, which minimizes the low-level mutation artifacts.
Results: This study demonstrates that this novel assay achieves high accuracy (positive percent agreement (PPA) for fusion: 98.5%; PPA and negative percent agreement (NPA) for mutation at 97.8% and 100.0%, respectively) and sensitivity (limit of detection (LOD) for mutation detection at 3% from 10 000 copies of BCR::ABL1 input).
Conclusions: The Dup-Seq BCR::ABL1 assay not only allows for the identification of BCR::ABL1 typical and atypical transcript types and accurate and sensitive detection of TKI-resistant mutations but also simplifies molecular testing work flow for the clinical management of CML patients.