Wireless temperature calibration for medical centrifuge

Tianyu Zhu , Ju Lu , Jian Shen , Jie Liu , Xinqing Xiao
{"title":"Wireless temperature calibration for medical centrifuge","authors":"Tianyu Zhu ,&nbsp;Ju Lu ,&nbsp;Jian Shen ,&nbsp;Jie Liu ,&nbsp;Xinqing Xiao","doi":"10.1016/j.sintl.2024.100296","DOIUrl":null,"url":null,"abstract":"<div><p>Based on the complexity and metrological requirements of temperature calibration within the rotor of a medical low-temperature centrifuge, a wireless temperature calibration device for medical centrifuges has been designed and developed. The temperature probe is integrated into the centrifuge tube, and the entire device can be placed inside the rotor of the centrifuge, allowing for the measurement and analysis of the actual temperature of the test solution inside the centrifuge tube under dynamic rotation conditions. Furthermore, the force situation during dynamic calibration is analyzed and performance tested. The calibration device can consistently and dependably achieve dynamic temperature data acquisition under high-speed conditions of medical low-temperature centrifuges, facilitating dynamic temperature calibration within the centrifuge rotor and offering support for centrifuge temperature control processes.</p></div>","PeriodicalId":21733,"journal":{"name":"Sensors International","volume":"6 ","pages":"Article 100296"},"PeriodicalIF":0.0000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666351124000184/pdfft?md5=082303b4d730f38f5435b6ecd2576988&pid=1-s2.0-S2666351124000184-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors International","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666351124000184","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Based on the complexity and metrological requirements of temperature calibration within the rotor of a medical low-temperature centrifuge, a wireless temperature calibration device for medical centrifuges has been designed and developed. The temperature probe is integrated into the centrifuge tube, and the entire device can be placed inside the rotor of the centrifuge, allowing for the measurement and analysis of the actual temperature of the test solution inside the centrifuge tube under dynamic rotation conditions. Furthermore, the force situation during dynamic calibration is analyzed and performance tested. The calibration device can consistently and dependably achieve dynamic temperature data acquisition under high-speed conditions of medical low-temperature centrifuges, facilitating dynamic temperature calibration within the centrifuge rotor and offering support for centrifuge temperature control processes.

用于医用离心机的无线温度校准
根据医用低温离心机转子内温度校准的复杂性和计量要求,设计并开发了一种用于医用离心机的无线温度校准装置。温度探头集成在离心管内,整个装置可放置在离心机转子内,可在动态旋转条件下测量和分析离心管内试液的实际温度。此外,还可对动态校准过程中的受力情况进行分析和性能测试。该校准装置可在医用低温离心机的高速条件下稳定可靠地实现动态温度数据采集,促进离心机转子内的动态温度校准,为离心机温度控制过程提供支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
17.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信