Domagoj Bošnjak, Antonio Pepe, Richard Schussnig, Jan Egger, Thomas-Peter Fries
{"title":"A semi-automatic method for block-structured hexahedral meshing of aortic dissections","authors":"Domagoj Bošnjak, Antonio Pepe, Richard Schussnig, Jan Egger, Thomas-Peter Fries","doi":"10.1002/cnm.3860","DOIUrl":null,"url":null,"abstract":"<p>The article presents a semi-automatic approach to generating structured hexahedral meshes of patient-specific aortas ailed by <i>aortic dissection</i>. The condition manifests itself as a formation of two blood flow channels in the aorta, as a result of a tear in the inner layers of the aortic wall. Subsequently, the morphology of the aorta is greatly impacted, making the task of domain discretization highly challenging. The meshing algorithm presented herein is automatic for the individual lumina, whereas the tears require user interaction. Starting from an input (triangle) surface mesh, we construct an <i>implicit surface representation</i> as well as a <i>topological skeleton</i>, which provides a basis for the generation of a <i>block-structure</i>. Thereafter, the mesh generation is performed via <i>transfinite maps</i>. The meshes are structured and fully hexahedral, exhibit good quality and reliably match the original surface. As they are generated with computational fluid dynamics in mind, a fluid flow simulation is performed to verify their usefulness. Moreover, since the approach is based on valid block-structures, the meshes can be made very coarse (around 1000 elements for an entire aortic dissection domain), and thus promote using solvers based on the geometric multigrid method, which is typically reliant on the presence of a hierarchy of coarser meshes.</p>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":"40 11","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2024-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cnm.3860","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cnm.3860","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The article presents a semi-automatic approach to generating structured hexahedral meshes of patient-specific aortas ailed by aortic dissection. The condition manifests itself as a formation of two blood flow channels in the aorta, as a result of a tear in the inner layers of the aortic wall. Subsequently, the morphology of the aorta is greatly impacted, making the task of domain discretization highly challenging. The meshing algorithm presented herein is automatic for the individual lumina, whereas the tears require user interaction. Starting from an input (triangle) surface mesh, we construct an implicit surface representation as well as a topological skeleton, which provides a basis for the generation of a block-structure. Thereafter, the mesh generation is performed via transfinite maps. The meshes are structured and fully hexahedral, exhibit good quality and reliably match the original surface. As they are generated with computational fluid dynamics in mind, a fluid flow simulation is performed to verify their usefulness. Moreover, since the approach is based on valid block-structures, the meshes can be made very coarse (around 1000 elements for an entire aortic dissection domain), and thus promote using solvers based on the geometric multigrid method, which is typically reliant on the presence of a hierarchy of coarser meshes.
期刊介绍:
All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.