{"title":"Transvenous embolization of patent ductus arteriosus in 16 dogs using the Amplatzer Vascular Plug II device: description of a modified technique and complications.","authors":"Antoine Dubès, Jean-Benoît Thambo, Virginie Loyer, Pierre Menaut","doi":"10.1292/jvms.23-0445","DOIUrl":null,"url":null,"abstract":"<p><p>Patent ductus arteriosus (PDA) is a deadly congenital disease in dogs if left untreated. Occlusion of the defect is the treatment of choice and can be achieved by surgical ligation or interventional closure. In this retrospective study of 16 dogs, an alternative to the classically used canine device which is placed by an arterial route is described. The Amplatzer Vascular Plug II<sup>®</sup> (AVPII) can be deployed by a transvenous approach, using a modified and simplified technique using a single catheter to perform angiography and device delivery. This allows the percutaneous treatment of smaller dogs <3 kg and the concomitant treatment of pulmonic stenosis if present. Successful and complete closure was achieved in all dogs with a mean device/ampulla diameter ratio of 1.28 and a mean device/ostium ratio of 3.6. Embolization into the pulmonary artery was observed in one dog where the device/ampulla diameter ratio was <1.1 and device/ostium ratio was <2.1. In conclusion, our study confirms that PDA transvenous closure using the AVPII appears to be a viable alternative to transarterial closure, allowing the treatment of smaller dogs and a fully percutaneous approach. Care should be taken in patients with very large ducti where undersizing might result in device embolization.</p>","PeriodicalId":49959,"journal":{"name":"Journal of Veterinary Medical Science","volume":" ","pages":"1089-1095"},"PeriodicalIF":1.1000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11442394/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Veterinary Medical Science","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1292/jvms.23-0445","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/2 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Patent ductus arteriosus (PDA) is a deadly congenital disease in dogs if left untreated. Occlusion of the defect is the treatment of choice and can be achieved by surgical ligation or interventional closure. In this retrospective study of 16 dogs, an alternative to the classically used canine device which is placed by an arterial route is described. The Amplatzer Vascular Plug II® (AVPII) can be deployed by a transvenous approach, using a modified and simplified technique using a single catheter to perform angiography and device delivery. This allows the percutaneous treatment of smaller dogs <3 kg and the concomitant treatment of pulmonic stenosis if present. Successful and complete closure was achieved in all dogs with a mean device/ampulla diameter ratio of 1.28 and a mean device/ostium ratio of 3.6. Embolization into the pulmonary artery was observed in one dog where the device/ampulla diameter ratio was <1.1 and device/ostium ratio was <2.1. In conclusion, our study confirms that PDA transvenous closure using the AVPII appears to be a viable alternative to transarterial closure, allowing the treatment of smaller dogs and a fully percutaneous approach. Care should be taken in patients with very large ducti where undersizing might result in device embolization.

使用 Amplatzer Vascular Plug II 装置对 16 只狗的动脉导管未闭进行经静脉栓塞治疗:改良技术及并发症描述。
如果不及时治疗,动脉导管未闭 (PDA) 是一种致命的先天性疾病。堵塞缺损是首选治疗方法,可通过手术结扎或介入闭合实现。在这项对 16 只犬进行的回顾性研究中,介绍了一种替代经典犬用装置的方法,即通过动脉途径置入。Amplatzer Vascular Plug II® (AVPII)可通过经静脉途径植入,采用经过改进的简化技术,使用一根导管进行血管造影和装置植入。这样就可以对较小的狗进行经皮治疗
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Veterinary Medical Science
Journal of Veterinary Medical Science 农林科学-兽医学
CiteScore
2.30
自引率
8.30%
发文量
230
审稿时长
9-18 weeks
期刊介绍: JVMS is a peer-reviewed journal and publishes a variety of papers on veterinary science from basic research to applied science and clinical research. JVMS is published monthly and consists of twelve issues per year. Papers are from the areas of anatomy, physiology, pharmacology, toxicology, pathology, immunology, microbiology, virology, parasitology, internal medicine, surgery, clinical pathology, theriogenology, avian disease, public health, ethology, and laboratory animal science. Although JVMS has played a role in publishing the scientific achievements of Japanese researchers and clinicians for many years, it now also accepts papers submitted from all over the world.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信