Relationship Between Asymmetry of Transverse Sinus and Difference in Intraocular Pressure.

IF 0.9 3区 医学 Q4 NEUROSCIENCES
Neurology India Pub Date : 2024-07-01 Epub Date: 2024-08-31 DOI:10.4103/neurol-india.NI_446_20
Dan Zhu, Weiguang Zhang, Dong Qiu, Dongtai Zhang, Yuanyuan Li, Jinping Li
{"title":"Relationship Between Asymmetry of Transverse Sinus and Difference in Intraocular Pressure.","authors":"Dan Zhu, Weiguang Zhang, Dong Qiu, Dongtai Zhang, Yuanyuan Li, Jinping Li","doi":"10.4103/neurol-india.NI_446_20","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>This study used two-dimensional time-of-flight magnetic resonance venography (2D TOF MRV) to show the shape of the transverse sinus and to determine whether there is a correlation between the asymmetry of the transverse sinus morphology and the intraocular pressure (IOP) of the two eyes.</p><p><strong>Methods: </strong>In this study, 63 male and 42 female volunteers were included. Those with obvious neurological diseases and eye diseases were excluded. According to the morphology of the transverse sinus scanned with 2D TOF MRV, subjects were divided into five groups. The IOP of the volunteers was measured separately.</p><p><strong>Results: </strong>The difference between group I and group V is statistically significant (Z = 6.78, P < 0.01). Statistically, significant differences also existed among the IOP of each group, including the mean values of both eyes and the difference between the right eye and the left eye. The asymmetry of the transverse sinus maintained a negative correlation with the right IOP (r = 0.51, P < 0.01) and the difference between the right eye and the left eye (r = 0.79, P < 0.01). The asymmetry and the left IOP had no statistical correlation.</p><p><strong>Conclusion: </strong>The preliminary conclusion of this study is that if one side of the transverse sinus is thicker, the drainage-related ocular veins are relatively coarser, and the IOP is relatively lower. The 2D TOF MRV examination can be used as an examination to show the shape of the transverse sinus. It is a display method to provide a feasible means of inspection for a reasonable interpretation.</p>","PeriodicalId":19429,"journal":{"name":"Neurology India","volume":"72 4","pages":"797-800"},"PeriodicalIF":0.9000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurology India","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/neurol-india.NI_446_20","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/31 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objective: This study used two-dimensional time-of-flight magnetic resonance venography (2D TOF MRV) to show the shape of the transverse sinus and to determine whether there is a correlation between the asymmetry of the transverse sinus morphology and the intraocular pressure (IOP) of the two eyes.

Methods: In this study, 63 male and 42 female volunteers were included. Those with obvious neurological diseases and eye diseases were excluded. According to the morphology of the transverse sinus scanned with 2D TOF MRV, subjects were divided into five groups. The IOP of the volunteers was measured separately.

Results: The difference between group I and group V is statistically significant (Z = 6.78, P < 0.01). Statistically, significant differences also existed among the IOP of each group, including the mean values of both eyes and the difference between the right eye and the left eye. The asymmetry of the transverse sinus maintained a negative correlation with the right IOP (r = 0.51, P < 0.01) and the difference between the right eye and the left eye (r = 0.79, P < 0.01). The asymmetry and the left IOP had no statistical correlation.

Conclusion: The preliminary conclusion of this study is that if one side of the transverse sinus is thicker, the drainage-related ocular veins are relatively coarser, and the IOP is relatively lower. The 2D TOF MRV examination can be used as an examination to show the shape of the transverse sinus. It is a display method to provide a feasible means of inspection for a reasonable interpretation.

横窦不对称与眼压差异之间的关系
背景和目的:本研究使用二维飞行时间磁共振静脉成像(2D TOF MRV)来显示横窦的形状,并确定横窦形态的不对称性与两眼眼压(IOP)之间是否存在相关性:本研究共纳入 63 名男性志愿者和 42 名女性志愿者。方法:本研究共纳入 63 名男性志愿者和 42 名女性志愿者,排除了患有明显神经系统疾病和眼部疾病的志愿者。根据二维 TOF MRV 扫描的横窦形态,受试者被分为五组。分别测量志愿者的眼压:第一组和第五组之间的差异具有统计学意义(Z = 6.78,P < 0.01)。从统计学角度看,各组的眼压之间也存在明显差异,包括双眼的平均值以及右眼和左眼之间的差异。横窦的不对称性与右眼眼压(r = 0.51,P < 0.01)以及右眼和左眼的差异(r = 0.79,P < 0.01)呈负相关。不对称与左眼眼压无统计学相关性:本研究的初步结论是,如果一侧横窦较厚,则与引流相关的眼静脉相对较粗,眼压相对较低。二维 TOF MRV 检查可用于显示横窦的形状。它是一种显示方法,为合理解释提供了可行的检查手段。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Neurology India
Neurology India 医学-神经科学
CiteScore
1.60
自引率
70.40%
发文量
434
审稿时长
2 months
期刊介绍: Neurology India (ISSN 0028-3886) is Bi-monthly publication of Neurological Society of India. Neurology India, the show window of the progress of Neurological Sciences in India, has successfully completed 50 years of publication in the year 2002. ‘Neurology India’, along with the Neurological Society of India, has grown stronger with the passing of every year. The full articles of the journal are now available on internet with more than 20000 visitors in a month and the journal is indexed in MEDLINE and Index Medicus, Current Contents, Neuroscience Citation Index and EMBASE in addition to 10 other indexing avenues. This specialty journal reaches to about 2000 neurologists, neurosurgeons, neuro-psychiatrists, and others working in the fields of neurology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信