Michele Girardi, Michael A Roman, Janos Porszasz, William W Stringer, Stephen Rennard, Carrie Ferguson, Harry B Rossiter, Richard Casaburi
{"title":"A Novel Method for Determining Ventilatory and Gas Exchange Dynamics During Exercise: The \"Chirp\" Waveform.","authors":"Michele Girardi, Michael A Roman, Janos Porszasz, William W Stringer, Stephen Rennard, Carrie Ferguson, Harry B Rossiter, Richard Casaburi","doi":"10.1152/japplphysiol.00358.2024","DOIUrl":null,"url":null,"abstract":"<p><p>Quantitating exercise ventilatory and gas exchange dynamics affords insights into physiological control processes and cardiopulmonary dysfunction. We designed a novel waveform, the chirp waveform, to efficiently extract moderate intensity exercise response dynamics. In the chirp waveform, work rate fluctuates sinusoidally with constant amplitude as sinusoidal period decreases progressively from approximately 8.5 to 1.4 minutes over 30 minutes of cycle ergometry. We hypothesized that response dynamics of pulmonary ventilation (V̇<sub>E</sub>) and gas exchange (V̇O<sub>2</sub> and V̇CO<sub>2</sub>) extracted from chirp waveform are similar to those obtained from step-wise transitions. Thirty-one participants (14 young-healthy, 7 older-healthy, 10 COPD patients) exercised on three occasions. Participants first performed ramp-incremental exercise for gas exchange threshold (GET) determination. In randomized order, the next two visits involved either chirp or step-wise waveforms. Work rate amplitude (20W to ∼95% GET work rate) and exercise duration (30 min) were the same for both waveforms. A first-order linear transfer function with system gain (<i>G</i>) and time constant (τ) characterized response dynamics. Agreement between model parameters extracted from chirp and step-wise waveforms was established using Bland-Altman analysis and Rothery's Concordance Coefficient (RCC). V̇<sub>E</sub>, V̇O<sub>2</sub>, and V̇CO<sub>2</sub> <i>G</i>s showed no systematic bias (p>0.178) and moderate-to-good agreement (RCC>0.772, p<0.01) between waveforms. Similarly, no systematic bias (p=0.815) and good agreement (RCC=0.837, p<0.001) was found for τV̇O<sub>2</sub>. Despite moderate agreement for τV̇CO<sub>2</sub> (RCC=0.794, p<0.001) and τV̇<sub>E</sub> (RCC=0.722, p=0.083), chirp τ was less (-6.9(11.7)s and -12.2(22.5)s, respectively). We conclude that the chirp waveform is a promising method for measuring exercise response dynamics and investigating physiological control mechanisms.</p>","PeriodicalId":15160,"journal":{"name":"Journal of applied physiology","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of applied physiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1152/japplphysiol.00358.2024","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Quantitating exercise ventilatory and gas exchange dynamics affords insights into physiological control processes and cardiopulmonary dysfunction. We designed a novel waveform, the chirp waveform, to efficiently extract moderate intensity exercise response dynamics. In the chirp waveform, work rate fluctuates sinusoidally with constant amplitude as sinusoidal period decreases progressively from approximately 8.5 to 1.4 minutes over 30 minutes of cycle ergometry. We hypothesized that response dynamics of pulmonary ventilation (V̇E) and gas exchange (V̇O2 and V̇CO2) extracted from chirp waveform are similar to those obtained from step-wise transitions. Thirty-one participants (14 young-healthy, 7 older-healthy, 10 COPD patients) exercised on three occasions. Participants first performed ramp-incremental exercise for gas exchange threshold (GET) determination. In randomized order, the next two visits involved either chirp or step-wise waveforms. Work rate amplitude (20W to ∼95% GET work rate) and exercise duration (30 min) were the same for both waveforms. A first-order linear transfer function with system gain (G) and time constant (τ) characterized response dynamics. Agreement between model parameters extracted from chirp and step-wise waveforms was established using Bland-Altman analysis and Rothery's Concordance Coefficient (RCC). V̇E, V̇O2, and V̇CO2Gs showed no systematic bias (p>0.178) and moderate-to-good agreement (RCC>0.772, p<0.01) between waveforms. Similarly, no systematic bias (p=0.815) and good agreement (RCC=0.837, p<0.001) was found for τV̇O2. Despite moderate agreement for τV̇CO2 (RCC=0.794, p<0.001) and τV̇E (RCC=0.722, p=0.083), chirp τ was less (-6.9(11.7)s and -12.2(22.5)s, respectively). We conclude that the chirp waveform is a promising method for measuring exercise response dynamics and investigating physiological control mechanisms.
期刊介绍:
The Journal of Applied Physiology publishes the highest quality original research and reviews that examine novel adaptive and integrative physiological mechanisms in humans and animals that advance the field. The journal encourages the submission of manuscripts that examine the acute and adaptive responses of various organs, tissues, cells and/or molecular pathways to environmental, physiological and/or pathophysiological stressors. As an applied physiology journal, topics of interest are not limited to a particular organ system. The journal, therefore, considers a wide array of integrative and translational research topics examining the mechanisms involved in disease processes and mitigation strategies, as well as the promotion of health and well-being throughout the lifespan. Priority is given to manuscripts that provide mechanistic insight deemed to exert an impact on the field.