Label-free ratiometric fluorescence detection of Pb2+via structure-specific fluorescent dyes and dual signal amplification

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Jinmin Zhang, Zhiguang Suo, Ruirui Liang, Min Wei, Wenjie Ren, Yiwei Xu, Baoshan He, Huali Jin and Renyong Zhao
{"title":"Label-free ratiometric fluorescence detection of Pb2+via structure-specific fluorescent dyes and dual signal amplification","authors":"Jinmin Zhang, Zhiguang Suo, Ruirui Liang, Min Wei, Wenjie Ren, Yiwei Xu, Baoshan He, Huali Jin and Renyong Zhao","doi":"10.1039/D4AY01369G","DOIUrl":null,"url":null,"abstract":"<p >Lead ions (Pb<small><sup>2+</sup></small>) are a widely distributed and highly toxic heavy metal pollutant, which seriously threatens the environment, economy and human safety. Here, a label-free ratiometric fluorescent biosensor was constructed for Pb<small><sup>2+</sup></small> detection using DNAzyme-driven target cycling and exonuclease III (Exo III)-mediated DNA cycling as a dual signal amplification strategy. The SYBR Green I (SGI) and <em>N</em>-methyl mesoporphyrin IX (NMM) used in this study are characterized by low cost, storage resistance, and short preparation time compared with conventional signaling probes labeled with fluorescent groups. Unlike the single-emission fluorescence strategy, monitoring the fluorescence intensity ratio of SGI and NMM can effectively reduce external interference to achieve accurate detection of Pb<small><sup>2+</sup></small>. DNAzyme structures on the surface of magnetic beads (MBs) can recognize Pb<small><sup>2+</sup></small> and activate the target circulatory system to cleave single-stranded DNA (ssDNA). The ssDNA further initiated the Exo III-assisted DNA circulatory system to digest double-stranded DNA (dsDNA) and release guanine-rich G1. Finally, the fluorescence signals of SGI and NMM were weakened and enhanced, respectively. The sensing strategy achieved a wide linear range from 0.5 to 500 nM and a low limit of detection (LOD) of 26.4 pM. Furthermore, its anti-interference ability and potential applicability for Pb<small><sup>2+</sup></small> detection in actual samples were verified. This work ingeniously combines the dual signal amplification strategy with the ratiometric sensing strategy constructed by structure-specific fluorescent dyes, which provides a promising method for constructing sensitive and accurate fluorescent biosensors.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ay/d4ay01369g","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Lead ions (Pb2+) are a widely distributed and highly toxic heavy metal pollutant, which seriously threatens the environment, economy and human safety. Here, a label-free ratiometric fluorescent biosensor was constructed for Pb2+ detection using DNAzyme-driven target cycling and exonuclease III (Exo III)-mediated DNA cycling as a dual signal amplification strategy. The SYBR Green I (SGI) and N-methyl mesoporphyrin IX (NMM) used in this study are characterized by low cost, storage resistance, and short preparation time compared with conventional signaling probes labeled with fluorescent groups. Unlike the single-emission fluorescence strategy, monitoring the fluorescence intensity ratio of SGI and NMM can effectively reduce external interference to achieve accurate detection of Pb2+. DNAzyme structures on the surface of magnetic beads (MBs) can recognize Pb2+ and activate the target circulatory system to cleave single-stranded DNA (ssDNA). The ssDNA further initiated the Exo III-assisted DNA circulatory system to digest double-stranded DNA (dsDNA) and release guanine-rich G1. Finally, the fluorescence signals of SGI and NMM were weakened and enhanced, respectively. The sensing strategy achieved a wide linear range from 0.5 to 500 nM and a low limit of detection (LOD) of 26.4 pM. Furthermore, its anti-interference ability and potential applicability for Pb2+ detection in actual samples were verified. This work ingeniously combines the dual signal amplification strategy with the ratiometric sensing strategy constructed by structure-specific fluorescent dyes, which provides a promising method for constructing sensitive and accurate fluorescent biosensors.

Abstract Image

通过结构特异性荧光染料和双重信号放大技术对 Pb2+ 进行无标记比率荧光检测。
铅离子(Pb2+)是一种分布广泛、毒性极强的重金属污染物,严重威胁环境、经济和人类安全。本文利用 DNA 酶驱动的靶循环和外切酶 III(Exo III)介导的 DNA 循环作为双重信号放大策略,构建了一种用于 Pb2+ 检测的无标记比率荧光生物传感器。与传统的荧光基团标记信号探针相比,本研究中使用的 SYBR Green I(SGI)和 N-甲基间卟啉 IX(NMM)具有成本低、耐储存、制备时间短等特点。与单发射荧光策略不同,监测 SGI 和 NMM 的荧光强度比可有效减少外界干扰,从而实现对 Pb2+ 的精确检测。磁珠(MBs)表面的 DNA 酶结构可识别 Pb2+,并激活目标循环系统裂解单链 DNA(ssDNA)。ssDNA进一步启动Exo III辅助的DNA循环系统,消化双链DNA(dsDNA)并释放出富含鸟嘌呤的G1。最后,SGI 和 NMM 的荧光信号分别减弱和增强。该传感策略实现了 0.5 至 500 nM 的宽线性范围和 26.4 pM 的低检测限 (LOD)。此外,该方法的抗干扰能力和在实际样品中检测 Pb2+ 的潜在适用性也得到了验证。该研究巧妙地将双信号放大策略与结构特异性荧光染料构建的比率测量传感策略相结合,为构建灵敏、准确的荧光生物传感器提供了一种可行的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信