{"title":"Hemoglobinopathy as a Rare Differential Disease for Low Oxygen Saturation by Pulse Oximetry: A Case Report and Literature Review.","authors":"Kenichiro Takeda, Toshihiko Sugiura, Satoshi Isomatsu, Hidemi Ogawa, Yushi Murai, Shizu Miyata, Shun Imai, Tadasu Okaya, Akira Naito, Ayumi Sekine, Ayako Shigeta, Takuji Suzuki","doi":"10.2169/internalmedicine.4011-24","DOIUrl":null,"url":null,"abstract":"<p><p>Pulse oximetry is used to screen for respiratory failure in dyspnea patients. However, pulse oximetry can yield false-positive results in certain situations. Unstable hemoglobinopathy is a disease in which mutations in the globin-encoding gene result in abnormal globin chain production, causing low percutaneous oxygen saturation (SpO<sub>2</sub>) levels due to changes in hemoglobin absorbance and oxygen affinity. We identified a new family lineage of Hb Hirosaki in an adult patient with chronic obstructive pulmonary disease, dyspnea, and low SpO<sub>2</sub>. According to our literature review, only a few cases of unstable hemoglobinopathy have been reported in adults. Most patients with unstable hemoglobinopathy are asymptomatic, and those with dyspnea often have respiratory diseases or severe anemia. To differentiate unstable hemoglobinopathy, an appropriate assessment of the discrepancy between SpO<sub>2</sub> values and arterial blood gas analysis results is important.</p>","PeriodicalId":13719,"journal":{"name":"Internal Medicine","volume":" ","pages":"987-991"},"PeriodicalIF":1.0000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Internal Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2169/internalmedicine.4011-24","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/28 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Pulse oximetry is used to screen for respiratory failure in dyspnea patients. However, pulse oximetry can yield false-positive results in certain situations. Unstable hemoglobinopathy is a disease in which mutations in the globin-encoding gene result in abnormal globin chain production, causing low percutaneous oxygen saturation (SpO2) levels due to changes in hemoglobin absorbance and oxygen affinity. We identified a new family lineage of Hb Hirosaki in an adult patient with chronic obstructive pulmonary disease, dyspnea, and low SpO2. According to our literature review, only a few cases of unstable hemoglobinopathy have been reported in adults. Most patients with unstable hemoglobinopathy are asymptomatic, and those with dyspnea often have respiratory diseases or severe anemia. To differentiate unstable hemoglobinopathy, an appropriate assessment of the discrepancy between SpO2 values and arterial blood gas analysis results is important.
期刊介绍:
Internal Medicine is an open-access online only journal published monthly by the Japanese Society of Internal Medicine.
Articles must be prepared in accordance with "The Uniform Requirements for Manuscripts Submitted to Biomedical Journals (see Annals of Internal Medicine 108: 258-265, 1988), must be contributed solely to the Internal Medicine, and become the property of the Japanese Society of Internal Medicine. Statements contained therein are the responsibility of the author(s). The Society reserves copyright and renewal on all published material and such material may not be reproduced in any form without the written permission of the Society.