{"title":"Open reduction internal fixation in patella fracture using wide awake local anesthesia no tourniquet technique (WALANT) – A case series","authors":"Chinnakart Boonyasirikool,&nbsp;Chananyu Susrivaraput,&nbsp;Sunyarn Niempoog","doi":"10.1016/j.pcorm.2024.100417","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Wide Awake Local Anesthesia No Tourniquet (WALANT) has been accepted safe and effective anesthesia technique for many orthopaedics procedures. Despite growing number of studies, few had described using WALANT in lower extremities with more complexity like the knee. We present a case series of patella fracture fixation using WALANT.</p></div><div><h3>Methods</h3><p>WALANT was used as a method of anesthesia for five patients diagnosed with patella fracture undergone tension band wiring fixation at Thammasat University hospital during 2021 - 2022. Visual analog scale (VAS) was collected throughout the surgery as primary objective and up to 48 h after the operation. We also evaluated their demographic and clinical data, range of motion, total operative time, amount of WALANT used, blood loss and hospital stay.</p></div><div><h3>Results</h3><p>Throughout the procedure, all patients reported no pain or discomfort except at wiring step which average VAS was 2.4 ± 1.14. The mean total operative time was 91.6 ± 18.58 min and mean WALANT solution used was 124 ± 12.94 ml. The visualization of surgical field was satisfying with minimal blood loss. All patients were able to walk with weight-bearing as tolerated right after the operation and were discharged in the same day except one due to lack of caregivers at home. Neither local nor systemic complications were found. No conversion to other anesthesia techniques due to failure of WALANT.</p></div><div><h3>Conclusions</h3><p>This study shows WALANT may be considered safe and effective as an alternative anesthesia technique for patella fracture fixation in ambulatory setting, offering favorable outcome without need for postoperative hospitalization.</p></div>","PeriodicalId":53468,"journal":{"name":"Perioperative Care and Operating Room Management","volume":"37 ","pages":"Article 100417"},"PeriodicalIF":0.0000,"publicationDate":"2024-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Perioperative Care and Operating Room Management","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2405603024000517","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Nursing","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Wide Awake Local Anesthesia No Tourniquet (WALANT) has been accepted safe and effective anesthesia technique for many orthopaedics procedures. Despite growing number of studies, few had described using WALANT in lower extremities with more complexity like the knee. We present a case series of patella fracture fixation using WALANT.

Methods

WALANT was used as a method of anesthesia for five patients diagnosed with patella fracture undergone tension band wiring fixation at Thammasat University hospital during 2021 - 2022. Visual analog scale (VAS) was collected throughout the surgery as primary objective and up to 48 h after the operation. We also evaluated their demographic and clinical data, range of motion, total operative time, amount of WALANT used, blood loss and hospital stay.

Results

Throughout the procedure, all patients reported no pain or discomfort except at wiring step which average VAS was 2.4 ± 1.14. The mean total operative time was 91.6 ± 18.58 min and mean WALANT solution used was 124 ± 12.94 ml. The visualization of surgical field was satisfying with minimal blood loss. All patients were able to walk with weight-bearing as tolerated right after the operation and were discharged in the same day except one due to lack of caregivers at home. Neither local nor systemic complications were found. No conversion to other anesthesia techniques due to failure of WALANT.

Conclusions

This study shows WALANT may be considered safe and effective as an alternative anesthesia technique for patella fracture fixation in ambulatory setting, offering favorable outcome without need for postoperative hospitalization.

采用宽清醒局部麻醉无止血带技术(WALANT)对髌骨骨折进行开放复位内固定术 - 病例研究
背景无止血带宽清醒局部麻醉(WALANT)已被公认为是许多骨科手术中安全有效的麻醉技术。尽管研究数量不断增加,但很少有研究描述在膝关节等复杂的下肢手术中使用 WALANT。方法2021-2022年间,WALANT作为一种麻醉方法被用于在Thammasat大学医院接受张力带接线固定术的五名髌骨骨折患者。在整个手术过程中以及术后 48 小时内,我们都收集了视觉模拟量表(VAS)作为主要目标。我们还评估了患者的人口统计学和临床数据、活动范围、手术总时间、WALANT使用量、失血量和住院时间。结果在整个手术过程中,所有患者均无疼痛或不适感,只有在接线步骤时例外,平均VAS为(2.4 ± 1.14)。手术总时间平均为 91.6 ± 18.58 分钟,WALANT 溶液平均用量为 124 ± 12.94 毫升。手术视野令人满意,失血量极少。所有患者在术后均可负重行走,除一名患者因家中缺少护理人员而无法行走外,其余患者均于当天出院。没有发现局部或全身并发症。结论:该研究表明,WALANT可被视为在非卧床环境下进行髌骨骨折固定术的一种安全有效的替代麻醉技术,无需术后住院即可获得良好的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Perioperative Care and Operating Room Management
Perioperative Care and Operating Room Management Nursing-Medical and Surgical Nursing
CiteScore
1.30
自引率
0.00%
发文量
52
审稿时长
56 days
期刊介绍: The objective of this new online journal is to serve as a multidisciplinary, peer-reviewed source of information related to the administrative, economic, operational, safety, and quality aspects of the ambulatory and in-patient operating room and interventional procedural processes. The journal will provide high-quality information and research findings on operational and system-based approaches to ensure safe, coordinated, and high-value periprocedural care. With the current focus on value in health care it is essential that there is a venue for researchers to publish articles on quality improvement process initiatives, process flow modeling, information management, efficient design, cost improvement, use of novel technologies, and management.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信