The Benefit of Hearing Aids as Measured by Listening Accuracy, Subjective Listening Effort, and Functional Near Infrared Spectroscopy.

IF 2.6 2区 医学 Q1 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
Jonathan M Vaisberg, Sean Gilmore, Jinyu Qian, Frank A Russo
{"title":"The Benefit of Hearing Aids as Measured by Listening Accuracy, Subjective Listening Effort, and Functional Near Infrared Spectroscopy.","authors":"Jonathan M Vaisberg, Sean Gilmore, Jinyu Qian, Frank A Russo","doi":"10.1177/23312165241273346","DOIUrl":null,"url":null,"abstract":"<p><p>There is broad consensus that listening effort is an important outcome for measuring hearing performance. However, there remains debate on the best ways to measure listening effort. This study sought to measure neural correlates of listening effort using functional near-infrared spectroscopy (fNIRS) in experienced adult hearing aid users. The study evaluated impacts of amplification and signal-to-noise ratio (SNR) on cerebral blood oxygenation, with the expectation that easier listening conditions would be associated with less oxygenation in the prefrontal cortex. Thirty experienced adult hearing aid users repeated sentence-final words from low-context Revised Speech Perception in Noise Test sentences. Participants repeated words at a hard SNR (individual SNR-50) or easy SNR (individual SNR-50 + 10 dB), while wearing hearing aids fit to prescriptive targets or without wearing hearing aids. In addition to assessing listening accuracy and subjective listening effort, prefrontal blood oxygenation was measured using fNIRS. As expected, easier listening conditions (i.e., easy SNR, with hearing aids) led to better listening accuracy, lower subjective listening effort, and lower oxygenation across the entire prefrontal cortex compared to harder listening conditions. Listening accuracy and subjective listening effort were also significant predictors of oxygenation.</p>","PeriodicalId":48678,"journal":{"name":"Trends in Hearing","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11363059/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trends in Hearing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/23312165241273346","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

There is broad consensus that listening effort is an important outcome for measuring hearing performance. However, there remains debate on the best ways to measure listening effort. This study sought to measure neural correlates of listening effort using functional near-infrared spectroscopy (fNIRS) in experienced adult hearing aid users. The study evaluated impacts of amplification and signal-to-noise ratio (SNR) on cerebral blood oxygenation, with the expectation that easier listening conditions would be associated with less oxygenation in the prefrontal cortex. Thirty experienced adult hearing aid users repeated sentence-final words from low-context Revised Speech Perception in Noise Test sentences. Participants repeated words at a hard SNR (individual SNR-50) or easy SNR (individual SNR-50 + 10 dB), while wearing hearing aids fit to prescriptive targets or without wearing hearing aids. In addition to assessing listening accuracy and subjective listening effort, prefrontal blood oxygenation was measured using fNIRS. As expected, easier listening conditions (i.e., easy SNR, with hearing aids) led to better listening accuracy, lower subjective listening effort, and lower oxygenation across the entire prefrontal cortex compared to harder listening conditions. Listening accuracy and subjective listening effort were also significant predictors of oxygenation.

通过聆听准确度、主观聆听努力程度和功能性近红外光谱测定助听器的益处。
人们普遍认为,听力强度是衡量听力表现的一个重要结果。然而,对于测量聆听强度的最佳方法仍存在争议。本研究试图利用功能性近红外光谱(fNIRS)测量经验丰富的成年助听器用户聆听强度的神经相关性。研究评估了放大率和信噪比(SNR)对脑血氧的影响,预计较轻松的聆听条件将与前额叶皮层较低的氧含量有关。30 位经验丰富的成人助听器使用者重复了低语境修订版噪声中言语感知测试句子中的句末单词。参与者在佩戴符合规定目标的助听器或不佩戴助听器的情况下,在较高信噪比(个人信噪比-50)或较低信噪比(个人信噪比-50 + 10 dB)下重复单词。除了评估听力准确性和主观听力努力程度外,还使用 fNIRS 测量了前额叶血氧饱和度。不出所料,与较难的听力条件相比,较容易的听力条件(即信噪比容易、佩戴助听器)会导致较高的听力准确性、较低的主观听力强度以及整个前额叶皮层较低的血氧饱和度。聆听准确性和主观聆听强度也是氧饱和度的重要预测因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Trends in Hearing
Trends in Hearing AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGYOTORH-OTORHINOLARYNGOLOGY
CiteScore
4.50
自引率
11.10%
发文量
44
审稿时长
12 weeks
期刊介绍: Trends in Hearing is an open access journal completely dedicated to publishing original research and reviews focusing on human hearing, hearing loss, hearing aids, auditory implants, and aural rehabilitation. Under its former name, Trends in Amplification, the journal established itself as a forum for concise explorations of all areas of translational hearing research by leaders in the field. Trends in Hearing has now expanded its focus to include original research articles, with the goal of becoming the premier venue for research related to human hearing and hearing loss.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信