Pediatric Failure Rates and Speech Outcomes in the HiRes Ultra and Ultra 3D Series Recall.

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Accounts of Chemical Research Pub Date : 2024-10-01 Epub Date: 2024-08-27 DOI:10.1097/MAO.0000000000004295
Taimur Siddiqui, Benjamin D Lovin, Michelle T Nguyen, Megan Marsh, Jessica B Spiro, Jennifer Wickesberg-Summers, Amy Cantu, Ronald J Vilela, Alex D Sweeney, Nathan R Lindquist
{"title":"Pediatric Failure Rates and Speech Outcomes in the HiRes Ultra and Ultra 3D Series Recall.","authors":"Taimur Siddiqui, Benjamin D Lovin, Michelle T Nguyen, Megan Marsh, Jessica B Spiro, Jennifer Wickesberg-Summers, Amy Cantu, Ronald J Vilela, Alex D Sweeney, Nathan R Lindquist","doi":"10.1097/MAO.0000000000004295","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The recent Field Corrective Action (FCA) for the HiRes Ultra and Ultra 3D (V1) cochlear implants (CIs) triggered much research investigating clinical identification, failure rates, and postrevision outcomes. Pediatric data remain limited, especially with regards to speech outcomes. We aim to characterize the trajectory of children implanted with these devices with specific attention to speech outcomes.</p><p><strong>Patients: </strong>Retrospective cohort study of pediatric patients with FCA-affected CIs from March 2017 to January 2020 at a tertiary children's hospital.</p><p><strong>Interventions: </strong>CI placement, device monitoring, audiologic evaluation, revision surgery.</p><p><strong>Main outcome measures: </strong>CI failure rates, revision surgery rate, speech recognition outcomes.</p><p><strong>Results: </strong>Forty-one devices were implanted in 27 pediatric patients. Average age at implantation was 4.01 years (range, 0.87-12.75). To date, 30 devices (73%) are known failures with 90% of these having undergone revision surgery. No statically significant difference was noted on open-set speech testing across best prerevision, immediate prerevision, and best postrevision time points. Best postrevision CNC scores had a mean score of 71% ± 26%, n = 16.</p><p><strong>Conclusions: </strong>Pediatric patients implanted with FCA-affected CI devices have a high risk of device failure. Open-set speech recognition was not significantly different from prerevision to postrevision testing, suggesting preserved speech outcomes. This may be partially attributable to limitations of cohort size and the pediatric population with open-set speech testing. However, we suspect that close follow-up with standardized testing and a low threshold for revision surgery provided by our multidisciplinary team may have mitigated these changes. Postrevision open-set speech testing remains positive for these patients.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MAO.0000000000004295","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/27 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The recent Field Corrective Action (FCA) for the HiRes Ultra and Ultra 3D (V1) cochlear implants (CIs) triggered much research investigating clinical identification, failure rates, and postrevision outcomes. Pediatric data remain limited, especially with regards to speech outcomes. We aim to characterize the trajectory of children implanted with these devices with specific attention to speech outcomes.

Patients: Retrospective cohort study of pediatric patients with FCA-affected CIs from March 2017 to January 2020 at a tertiary children's hospital.

Interventions: CI placement, device monitoring, audiologic evaluation, revision surgery.

Main outcome measures: CI failure rates, revision surgery rate, speech recognition outcomes.

Results: Forty-one devices were implanted in 27 pediatric patients. Average age at implantation was 4.01 years (range, 0.87-12.75). To date, 30 devices (73%) are known failures with 90% of these having undergone revision surgery. No statically significant difference was noted on open-set speech testing across best prerevision, immediate prerevision, and best postrevision time points. Best postrevision CNC scores had a mean score of 71% ± 26%, n = 16.

Conclusions: Pediatric patients implanted with FCA-affected CI devices have a high risk of device failure. Open-set speech recognition was not significantly different from prerevision to postrevision testing, suggesting preserved speech outcomes. This may be partially attributable to limitations of cohort size and the pediatric population with open-set speech testing. However, we suspect that close follow-up with standardized testing and a low threshold for revision surgery provided by our multidisciplinary team may have mitigated these changes. Postrevision open-set speech testing remains positive for these patients.

HiRes Ultra 和 Ultra 3D 系列产品召回中的儿科失败率和言语效果。
目的:最近,针对 HiRes Ultra 和 Ultra 3D (V1) 人工耳蜗(CI)的现场纠正行动(FCA)引发了对临床识别、故障率和复视后效果的大量研究。儿科数据仍然有限,尤其是在言语效果方面。我们的目标是描述植入这些设备的儿童的成长轨迹,并特别关注言语效果:回顾性队列研究:2017 年 3 月至 2020 年 1 月在一家三级儿童医院接受 FCA 影响的 CI 的儿科患者:CI置入、设备监测、听力学评估、翻修手术:CI失败率、翻修手术率、语言识别结果:结果:27 名儿童患者植入了 41 个设备。平均植入年龄为 4.01 岁(0.87-12.75 岁)。迄今为止,已知有 30 台设备(73%)出现故障,其中 90% 接受过翻修手术。在最佳矫治前、即刻矫治前和最佳矫治后时间点的开放式言语测试中,没有发现明显的统计学差异。最佳术后 CNC 评分的平均值为 71% ± 26%,n = 16.结论:植入受 FCA 影响的 CI 设备的儿童患者出现设备故障的风险很高。开放集语音识别能力与配戴前和配戴后的测试结果没有明显差异,这表明语音识别能力得到了保留。这可能部分归因于队列规模和开放式语音测试的儿科人群的局限性。不过,我们认为,我们的多学科团队提供的标准化测试的密切跟踪和较低的翻修手术门槛可能减轻了这些变化。对这些患者来说,复明后的开放式言语测试仍然是积极的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信