Development and clinical implementation of an LC-HRMS method for ivacaftor, lumacaftor, tezacaftor and elexacaftor in human plasma and breast milk.

IF 3.8 2区 化学 Q1 BIOCHEMICAL RESEARCH METHODS
Analytical and Bioanalytical Chemistry Pub Date : 2024-11-01 Epub Date: 2024-08-28 DOI:10.1007/s00216-024-05496-2
Anna B Hansson, Hjalmar Wadström, Erik Eliasson, Mahasin Al Shakirchi, Isabelle de Monestrol, Victoria Barclay
{"title":"Development and clinical implementation of an LC-HRMS method for ivacaftor, lumacaftor, tezacaftor and elexacaftor in human plasma and breast milk.","authors":"Anna B Hansson, Hjalmar Wadström, Erik Eliasson, Mahasin Al Shakirchi, Isabelle de Monestrol, Victoria Barclay","doi":"10.1007/s00216-024-05496-2","DOIUrl":null,"url":null,"abstract":"<p><p>The four cystic fibrosis (CF) transmembrane conductance regulator (CFTR) modulators, ivacaftor, lumacaftor, tezacaftor, and elexacaftor, have revolutionised the treatment of CF by direct action on the protein target behind the disease's development. The aim was to develop and validate a quantification method for these CFTR modulators in plasma and breast milk to better understand inter-patient variability in pharmacokinetics and treatment outcome, including the risk of adverse drug reactions. The ability to monitor CFTR modulators in breast milk enables the estimation of the exposure of breastfed infant, with a potential concern for CFTR modulator-induced liver injury. The analysis was performed on a Thermo Vanquish Flex Binary UHPLC system coupled to a high-resolution mass spectrometer (HRMS), Thermo Q Exactive. The analytes were detected using positive electrospray ionisation in full scan mode. After sample preparation by protein precipitation, the supernatant was injected onto the LC system and the analytes were separated using a Zorbax SB-C18 Rapid Res HPLC column (3.5 µm, 4.6 × 75 mm). This is the first published method for CFTR modulators in breast milk. The validated quantification range for ivacaftor is 0.0050-10 µg/mL with a coefficient of variation < 6% and a mean accuracy of 97-106%; for lumacaftor, tezacaftor, and elexacaftor, the validated quantification range is 0.050-100 µg/mL with a coefficient of variation < 8% and a mean accuracy 93-106%. A simple and sensitive quantification method for CFTR modulators has been developed and used for routine analysis of human plasma and breast milk samples since 2022.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11493817/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-024-05496-2","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/28 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

The four cystic fibrosis (CF) transmembrane conductance regulator (CFTR) modulators, ivacaftor, lumacaftor, tezacaftor, and elexacaftor, have revolutionised the treatment of CF by direct action on the protein target behind the disease's development. The aim was to develop and validate a quantification method for these CFTR modulators in plasma and breast milk to better understand inter-patient variability in pharmacokinetics and treatment outcome, including the risk of adverse drug reactions. The ability to monitor CFTR modulators in breast milk enables the estimation of the exposure of breastfed infant, with a potential concern for CFTR modulator-induced liver injury. The analysis was performed on a Thermo Vanquish Flex Binary UHPLC system coupled to a high-resolution mass spectrometer (HRMS), Thermo Q Exactive. The analytes were detected using positive electrospray ionisation in full scan mode. After sample preparation by protein precipitation, the supernatant was injected onto the LC system and the analytes were separated using a Zorbax SB-C18 Rapid Res HPLC column (3.5 µm, 4.6 × 75 mm). This is the first published method for CFTR modulators in breast milk. The validated quantification range for ivacaftor is 0.0050-10 µg/mL with a coefficient of variation < 6% and a mean accuracy of 97-106%; for lumacaftor, tezacaftor, and elexacaftor, the validated quantification range is 0.050-100 µg/mL with a coefficient of variation < 8% and a mean accuracy 93-106%. A simple and sensitive quantification method for CFTR modulators has been developed and used for routine analysis of human plasma and breast milk samples since 2022.

Abstract Image

针对人血浆和母乳中的 ivacaftor、lumacaftor、tezacaftor 和 elexacaftor,开发 LC-HRMS 方法并进行临床应用。
四种囊性纤维化(CF)跨膜传导调节剂(CFTR)调节剂--ivacaftor、lumacaftor、tezacaftor和lexacaftor--通过直接作用于疾病发展背后的蛋白靶点,彻底改变了CF的治疗方法。我们的目标是开发并验证血浆和母乳中这些 CFTR 调节剂的定量方法,以便更好地了解患者间药代动力学和治疗效果的差异,包括药物不良反应的风险。通过监测母乳中的 CFTR 调节剂,可以估算母乳喂养婴儿的暴露量,这可能会导致 CFTR 调节剂引起的肝损伤。分析在 Thermo Vanquish Flex Binary UHPLC 系统上进行,该系统与高分辨率质谱仪 (HRMS) Thermo Q Exactive 相连接。在全扫描模式下使用正电喷雾离子化技术检测分析物。通过蛋白质沉淀进行样品制备后,将上清液注入液相色谱系统,使用 Zorbax SB-C18 Rapid Res HPLC 色谱柱(3.5 µm,4.6 × 75 mm)分离分析物。这是首次公布的母乳中 CFTR 调节剂的检测方法。伊伐卡夫多的有效定量范围为 0.0050-10 µg/mL,变异系数为 0.9%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.00
自引率
4.70%
发文量
638
审稿时长
2.1 months
期刊介绍: Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信