Peini Zhao, Yujiao Bai, Chuanrui Zhao, Wenqing Gao, Pan Ma, Jinghua Yu, Yan Zhang, Peihua Zhu
{"title":"Multiwalled Carbon Nanotube-Templated Nickel Porphyrin Covalent Organic Framework for Pencil-Drawn Noninvasive Respiration Sensors.","authors":"Peini Zhao, Yujiao Bai, Chuanrui Zhao, Wenqing Gao, Pan Ma, Jinghua Yu, Yan Zhang, Peihua Zhu","doi":"10.1021/acssensors.4c01096","DOIUrl":null,"url":null,"abstract":"<p><p>Paper-integrated configuration with miniaturized functionality represents one of the future main green electronics. In this study, a paper-based respiration sensor was prepared using a multiwalled carbon nanotube-templated nickel porphyrin covalent organic framework (MWCNTs@COF<sub>NiP-Ph</sub>) as an electrical identification component and pencil-drawn graphite electric circuits as interdigitated electrodes (IDEs). The MWCNTs@COF<sub>NiP-Ph</sub> not only inherited the high gas sensing performance of porphyrin and the aperture induction effect of COFs but also overcame the shielding effect between phases through the MWCNT template. Furthermore, it possessed highly exposed M-N<sub>4</sub> metallic active sites and unique periodic porosity, thereby effectively addressing the key technical issue of room-temperature sensing for the respiration sensor. Meanwhile, the introduction of a pencil-drawing approach on common printing papers facilitates the inexpensive and simple manufacturing of the as-fabricated graphite IDE. Based on the above advantages, the MWCNTs@COF<sub>NiP-Ph</sub> respiration sensor had the characteristics of wide detection range (1-500 ppm), low detection limit (30 ppb), acceptable flexibility for toluene, and rapid response/recovery time (32 s/116 s). These advancements facilitated the integration of the respiration sensor into surgical masks and clothes with maximum functionality at a minimized size and weight. Moreover, the primary internal mechanism of COF<sub>NiP-Ph</sub> for this efficient toluene detection was investigated through in situ FTIR spectra, thereby directly elucidating that the chemisorption interaction of oxygen modulated the depletion layers, resulting in alterations in sensor resistance upon exposure to the target gas. The encouraging results revealed the feasibility of employing a paper-sensing system as a wearable platform in green electronics.</p>","PeriodicalId":24,"journal":{"name":"ACS Sensors","volume":null,"pages":null},"PeriodicalIF":8.2000,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Sensors","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acssensors.4c01096","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/26 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Paper-integrated configuration with miniaturized functionality represents one of the future main green electronics. In this study, a paper-based respiration sensor was prepared using a multiwalled carbon nanotube-templated nickel porphyrin covalent organic framework (MWCNTs@COFNiP-Ph) as an electrical identification component and pencil-drawn graphite electric circuits as interdigitated electrodes (IDEs). The MWCNTs@COFNiP-Ph not only inherited the high gas sensing performance of porphyrin and the aperture induction effect of COFs but also overcame the shielding effect between phases through the MWCNT template. Furthermore, it possessed highly exposed M-N4 metallic active sites and unique periodic porosity, thereby effectively addressing the key technical issue of room-temperature sensing for the respiration sensor. Meanwhile, the introduction of a pencil-drawing approach on common printing papers facilitates the inexpensive and simple manufacturing of the as-fabricated graphite IDE. Based on the above advantages, the MWCNTs@COFNiP-Ph respiration sensor had the characteristics of wide detection range (1-500 ppm), low detection limit (30 ppb), acceptable flexibility for toluene, and rapid response/recovery time (32 s/116 s). These advancements facilitated the integration of the respiration sensor into surgical masks and clothes with maximum functionality at a minimized size and weight. Moreover, the primary internal mechanism of COFNiP-Ph for this efficient toluene detection was investigated through in situ FTIR spectra, thereby directly elucidating that the chemisorption interaction of oxygen modulated the depletion layers, resulting in alterations in sensor resistance upon exposure to the target gas. The encouraging results revealed the feasibility of employing a paper-sensing system as a wearable platform in green electronics.
期刊介绍:
ACS Sensors is a peer-reviewed research journal that focuses on the dissemination of new and original knowledge in the field of sensor science, particularly those that selectively sense chemical or biological species or processes. The journal covers a broad range of topics, including but not limited to biosensors, chemical sensors, gas sensors, intracellular sensors, single molecule sensors, cell chips, and microfluidic devices. It aims to publish articles that address conceptual advances in sensing technology applicable to various types of analytes or application papers that report on the use of existing sensing concepts in new ways or for new analytes.