{"title":"The sensitive detection of low molecular mass peptide drugs in dried blood spots by solid-phase extraction and LC-HRMS.","authors":"Wei Chang, Siyu Yan, Xiya Yan, Zhanliang Wang, Boya Gu, Yunxi Liu, Yufeng Zhang, Sheng Yang","doi":"10.1007/s00216-024-05480-w","DOIUrl":null,"url":null,"abstract":"<p><p>Dried blood spot (DBS) technique has become a new popular topic in anti-doping field in recent years due to its advantages of sample stability and easy operation. It can be employed as a supplementary method to routine urine analysis. However, the small volume of DBS samples (usually 10-20 μL) significantly reduces the application value of this technique. Therefore, the development of sensitive detection methods for the analysis of prohibited substances in DBS is particularly important. In this study, based on the characteristics of low molecular mass peptide (LMMP) drugs, systematic optimization strategies were utilized for the first time to establish a sensitive detection method for LMMPs in DBS. Without using DMSO to enhance mass spectrometry ionization efficiency of peptides, the limits of detection (LOD) ranged between 0.05 and 3.74 ng/mL, significantly better than the previously reported method (0.5-20 ng/mL). This method was validated according to the guidelines of the World Anti-Doping Agency (WADA), and corresponding post-administration study was conducted, demonstrating that the method could be applied to routine analysis of LMMP drugs in DBS. Moreover, since DMSO is not involved, this method also has the potential to simultaneously detect both LMMP and small molecular drugs.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-024-05480-w","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/24 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Dried blood spot (DBS) technique has become a new popular topic in anti-doping field in recent years due to its advantages of sample stability and easy operation. It can be employed as a supplementary method to routine urine analysis. However, the small volume of DBS samples (usually 10-20 μL) significantly reduces the application value of this technique. Therefore, the development of sensitive detection methods for the analysis of prohibited substances in DBS is particularly important. In this study, based on the characteristics of low molecular mass peptide (LMMP) drugs, systematic optimization strategies were utilized for the first time to establish a sensitive detection method for LMMPs in DBS. Without using DMSO to enhance mass spectrometry ionization efficiency of peptides, the limits of detection (LOD) ranged between 0.05 and 3.74 ng/mL, significantly better than the previously reported method (0.5-20 ng/mL). This method was validated according to the guidelines of the World Anti-Doping Agency (WADA), and corresponding post-administration study was conducted, demonstrating that the method could be applied to routine analysis of LMMP drugs in DBS. Moreover, since DMSO is not involved, this method also has the potential to simultaneously detect both LMMP and small molecular drugs.
期刊介绍:
Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.