Transcranial ultrafast ultrasound Doppler imaging: A phantom study

IF 3.8 2区 物理与天体物理 Q1 ACOUSTICS
Jiangjin Zhou , Yuanyang Guo , Qiandong Sun , Fanglue Lin , Chen Jiang , Kailiang Xu , Dean Ta
{"title":"Transcranial ultrafast ultrasound Doppler imaging: A phantom study","authors":"Jiangjin Zhou ,&nbsp;Yuanyang Guo ,&nbsp;Qiandong Sun ,&nbsp;Fanglue Lin ,&nbsp;Chen Jiang ,&nbsp;Kailiang Xu ,&nbsp;Dean Ta","doi":"10.1016/j.ultras.2024.107430","DOIUrl":null,"url":null,"abstract":"<div><p>Ultrafast ultrasound Doppler imaging facilitates the assessment of cerebral hemodynamics with high spatio-temporal resolution. However, the significant acoustic impedance mismatch between the skull and soft tissue results in phase aberrations, which can compromise the quality of transcranial imaging and introduce biases in velocity and direction quantification of blood flow. This paper proposed an aberration correction method that combines deep learning-based skull sound speed modelling with ray theory to realize transcranial plane-wave imaging and ultrafast Doppler imaging. The method was validated through phantom experiments using a linear array with a center frequency of 6.25 MHz, 128 elements, and a pitch of 0.3 mm. The results demonstrated an improvement in the imaging quality of intracranial targets when using the proposed method. After aberration correction, the average locating deviation decreased from 1.40 mm to 0.27 mm in the axial direction, from 0.50 mm to 0.20 mm in the lateral direction, and the average full-width-at-half-maximum (FWHM) decreased from 1.37 mm to 0.97 mm for point scatterers. For circular inclusions, the average contrast-to-noise ratio (CNR) improved from 8.1 dB to 11.0 dB, and the average eccentricity decreased from 0.36 to 0.26. Furthermore, the proposed method was applied to transcranial ultrafast Doppler flow imaging. The results showed a significant improvement in accuracy and quality for blood Doppler flow imaging. The results in the absence of the skull were considered as the reference, and the average normalized root-mean-square errors of the axial velocity component on the five selected axial profiles were reduced from 17.67% to 8.02% after the correction.</p></div>","PeriodicalId":23522,"journal":{"name":"Ultrasonics","volume":"144 ","pages":"Article 107430"},"PeriodicalIF":3.8000,"publicationDate":"2024-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonics","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0041624X24001938","RegionNum":2,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Ultrafast ultrasound Doppler imaging facilitates the assessment of cerebral hemodynamics with high spatio-temporal resolution. However, the significant acoustic impedance mismatch between the skull and soft tissue results in phase aberrations, which can compromise the quality of transcranial imaging and introduce biases in velocity and direction quantification of blood flow. This paper proposed an aberration correction method that combines deep learning-based skull sound speed modelling with ray theory to realize transcranial plane-wave imaging and ultrafast Doppler imaging. The method was validated through phantom experiments using a linear array with a center frequency of 6.25 MHz, 128 elements, and a pitch of 0.3 mm. The results demonstrated an improvement in the imaging quality of intracranial targets when using the proposed method. After aberration correction, the average locating deviation decreased from 1.40 mm to 0.27 mm in the axial direction, from 0.50 mm to 0.20 mm in the lateral direction, and the average full-width-at-half-maximum (FWHM) decreased from 1.37 mm to 0.97 mm for point scatterers. For circular inclusions, the average contrast-to-noise ratio (CNR) improved from 8.1 dB to 11.0 dB, and the average eccentricity decreased from 0.36 to 0.26. Furthermore, the proposed method was applied to transcranial ultrafast Doppler flow imaging. The results showed a significant improvement in accuracy and quality for blood Doppler flow imaging. The results in the absence of the skull were considered as the reference, and the average normalized root-mean-square errors of the axial velocity component on the five selected axial profiles were reduced from 17.67% to 8.02% after the correction.

经颅超快超声多普勒成像:模型研究。
超快超声多普勒成像有助于以高时空分辨率评估脑血流动力学。然而,颅骨和软组织之间明显的声阻抗不匹配会导致相位畸变,从而影响经颅成像的质量,并在血流的速度和方向量化方面带来偏差。本文提出了一种畸变校正方法,将基于深度学习的颅骨声速建模与射线理论相结合,以实现经颅平面波成像和超快多普勒成像。该方法通过使用中心频率为 6.25 MHz、128 个元素、间距为 0.3 mm 的线性阵列进行幻影实验进行了验证。结果表明,使用该方法可提高颅内目标的成像质量。校正像差后,对于点散射体,平均定位偏差在轴向从 1.40 毫米减小到 0.27 毫米,在侧向从 0.50 毫米减小到 0.20 毫米,平均最大半宽(FWHM)从 1.37 毫米减小到 0.97 毫米。对于圆形内含物,平均对比度-噪声比(CNR)从 8.1 dB 提高到 11.0 dB,平均偏心率从 0.36 降低到 0.26。此外,该方法还被应用于经颅超快多普勒血流成像。结果表明,血液多普勒血流成像的准确性和质量都有明显提高。以无颅骨时的结果为参考,校正后五个选定轴向剖面上轴向速度分量的平均归一化均方根误差从 17.67% 降至 8.02%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ultrasonics
Ultrasonics 医学-核医学
CiteScore
7.60
自引率
19.00%
发文量
186
审稿时长
3.9 months
期刊介绍: Ultrasonics is the only internationally established journal which covers the entire field of ultrasound research and technology and all its many applications. Ultrasonics contains a variety of sections to keep readers fully informed and up-to-date on the whole spectrum of research and development throughout the world. Ultrasonics publishes papers of exceptional quality and of relevance to both academia and industry. Manuscripts in which ultrasonics is a central issue and not simply an incidental tool or minor issue, are welcomed. As well as top quality original research papers and review articles by world renowned experts, Ultrasonics also regularly features short communications, a calendar of forthcoming events and special issues dedicated to topical subjects.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信