Duodenal ileus caused by a cage magnet in a Fleckvieh cow.

IF 0.4 4区 农林科学 Q4 VETERINARY SCIENCES
Lisa Huber, Melanie Feist, Gabriela Knubben-Schweizer, Florian M Trefz
{"title":"Duodenal ileus caused by a cage magnet in a Fleckvieh cow.","authors":"Lisa Huber, Melanie Feist, Gabriela Knubben-Schweizer, Florian M Trefz","doi":"10.1055/a-2365-5457","DOIUrl":null,"url":null,"abstract":"<p><p>The present report aims to describe the case of a duodenal obstruction ileus in a dairy cow that was caused by a cage magnet. The 4.7-year-old German Fleckvieh cow was hospitalized because of symptoms of intestinal obstruction such as anorexia, noticeable drop in milk yield, reduced defecation, dehydration and positive percussion and swinging auscultation in a circumscribed area cranial of the right flank over the last 2 ribs. Six months as well as 3 days prior to hospitalization the cow had already been treated for signs of hardware disease, which included administration of a cage magnet.After the initial clinical diagnostic procedure on hospital admission, a diagnostic laparotomy in the right paralumbar fossa was performed to identify the cause of the ileus. The cranial part of the duodenum was markedly dilated, and a solid foreign body was found obstructing the intestine immediately aboral to the duodenal sigmoid flexure. This was identified as a cage magnet, which was massaged in retrograde direction into the pyloric antrum and removed via abomasotomy. The cow recovered from surgical intervention and was discharged from the hospital 6 days later.The present report describes an unusual complication of cage magnet administration, which is a standard veterinary procedure and generally considered a safe treatment option in cows with clinical signs of acute traumatic reticuloperitonitis.</p>","PeriodicalId":23115,"journal":{"name":"Tieraerztliche Praxis Ausgabe Grosstiere Nutztiere","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tieraerztliche Praxis Ausgabe Grosstiere Nutztiere","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1055/a-2365-5457","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/22 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

The present report aims to describe the case of a duodenal obstruction ileus in a dairy cow that was caused by a cage magnet. The 4.7-year-old German Fleckvieh cow was hospitalized because of symptoms of intestinal obstruction such as anorexia, noticeable drop in milk yield, reduced defecation, dehydration and positive percussion and swinging auscultation in a circumscribed area cranial of the right flank over the last 2 ribs. Six months as well as 3 days prior to hospitalization the cow had already been treated for signs of hardware disease, which included administration of a cage magnet.After the initial clinical diagnostic procedure on hospital admission, a diagnostic laparotomy in the right paralumbar fossa was performed to identify the cause of the ileus. The cranial part of the duodenum was markedly dilated, and a solid foreign body was found obstructing the intestine immediately aboral to the duodenal sigmoid flexure. This was identified as a cage magnet, which was massaged in retrograde direction into the pyloric antrum and removed via abomasotomy. The cow recovered from surgical intervention and was discharged from the hospital 6 days later.The present report describes an unusual complication of cage magnet administration, which is a standard veterinary procedure and generally considered a safe treatment option in cows with clinical signs of acute traumatic reticuloperitonitis.

弗莱克维赫奶牛因笼子磁铁引起的十二指肠回流。
本报告旨在描述一例由笼子磁铁引起的奶牛十二指肠回肠梗阻。这头 4.7 岁的德国弗莱克维赫奶牛因出现肠梗阻症状而住院治疗,这些症状包括厌食、产奶量明显下降、排便减少、脱水以及右侧胁部最后 2 根肋骨周围区域的叩诊和摇摆听诊阳性。入院前6个月和3天,该奶牛已经接受过硬件疾病治疗,包括笼磁治疗。入院时进行初步临床诊断后,在右侧脐窝进行了诊断性开腹手术,以确定回肠梗阻的原因。十二指肠头端明显扩张,在紧靠十二指肠乙状结肠弯曲处发现一个固体异物阻塞肠道。经鉴定,这是一块笼形磁铁,将其逆行按摩到幽门窦内,并通过腹腔切开术将其取出。本报告描述了笼式磁铁注射的不寻常并发症,笼式磁铁注射是一种标准的兽医程序,通常被认为是对有急性创伤性网状腹膜炎临床症状的奶牛的一种安全治疗方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.80
自引率
0.00%
发文量
82
期刊介绍: Die Tierärztliche Praxis wendet sich mit ihren beiden Reihen als einzige veterinärmedizinische Fachzeitschrift explizit an den Großtier- bzw. Kleintierpraktiker und garantiert damit eine zielgruppengenaue Ansprache. Für den Spezialisten bietet sie Original- oder Übersichtsartikel zu neuen Therapie- und Operationsverfahren oder den Einsatz moderner bildgebender Verfahren. Der weniger spezialisierte Tierarzt oder Berufseinsteiger findet auf seinen Berufsalltag zugeschnittene praxisbezogene Beiträge in der Fortbildungsrubrik „Aus Studium und Praxis“. Mit dem hervorgehobenen „Fazit für die Praxis“ am Ende jedes Artikels verschafft sich auch der eilige Leser einen raschen Überblick über die wichtigsten Inhalte dieser modern konzipierten Fachzeitschrift mit den vielen hochwertigen, überwiegend farbigen Abbildungen. In jedem Heft ermöglicht ein ATF-anerkannter Fortbildungsartikel den Erwerb einer ATF-Stunde (Akademie für tierärztliche Fortbildung).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信