[Clinical Efficacy of Anchor Suture Bridge Technique for Avulsion Fractures of the Posterior Cruciate Ligament Tibial Insertion Point in the Knee Joint].
Xiucheng Chu, Yanhua Li, Yanqing Zheng, Yuemei Li, Fengli Wang
{"title":"[Clinical Efficacy of Anchor Suture Bridge Technique for Avulsion Fractures of the Posterior Cruciate Ligament Tibial Insertion Point in the Knee Joint].","authors":"Xiucheng Chu, Yanhua Li, Yanqing Zheng, Yuemei Li, Fengli Wang","doi":"10.12182/20240760106","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the clinical efficacy of the anchor suture bridge technique in treating avulsion fractures at the tibial insertion point of the posterior cruciate ligament (PCL) in the knee joint.</p><p><strong>Methods: </strong>In this study, we reviewed 80 patients with PCL tibial avulsion fractures treated using the anchor suture bridge technique in our department from February 2010 to December 2023. Follow-ups were conducted starting at 3 months post-surgery, then every 3 months until 12 months post-surgery. Clinical and follow-up data of each patient were analyzed. The Lysholm and Hospital for Special Surgery Knee-Rating Scale (HSS) scores of knee function before surgery and at the last follow-up were compared to assess the surgical treatment outcome.</p><p><strong>Results: </strong>The 80 patients were followed up for an average of (12.16±1.08) months post-surgery. Re-examination X-rays showed that all fractures had healed, with an average healing time of (3.66±0.51) months. All patients recovered well, with primary healing of surgical incisions and no complications such as neurovascular injury, skin necrosis, incision infection, fracture displacement, or ligament laxity. Postoperative knee Lysholm and HSS scores were significantly higher than preoperative scores. At the last follow-up, the Lysholm score increased from (46.30±6.10) preoperatively to (90.85±3.27), and the HSS score increased from (45.30±5.80) to (91.15±2.66), with statistically significant differences (<i>P</i><0.025).</p><p><strong>Conclusion: </strong>The anchor suture bridge technique is effective in treating avulsion fractures of the PCL tibial insertion point in the knee joint. It has a high safety profile and leads to good postoperative knee function recovery, with no serious postoperative complications, demonstrating excellent clinical efficacy.</p>","PeriodicalId":39321,"journal":{"name":"四川大学学报(医学版)","volume":"55 4","pages":"1020-1025"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11334289/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"四川大学学报(医学版)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.12182/20240760106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To investigate the clinical efficacy of the anchor suture bridge technique in treating avulsion fractures at the tibial insertion point of the posterior cruciate ligament (PCL) in the knee joint.
Methods: In this study, we reviewed 80 patients with PCL tibial avulsion fractures treated using the anchor suture bridge technique in our department from February 2010 to December 2023. Follow-ups were conducted starting at 3 months post-surgery, then every 3 months until 12 months post-surgery. Clinical and follow-up data of each patient were analyzed. The Lysholm and Hospital for Special Surgery Knee-Rating Scale (HSS) scores of knee function before surgery and at the last follow-up were compared to assess the surgical treatment outcome.
Results: The 80 patients were followed up for an average of (12.16±1.08) months post-surgery. Re-examination X-rays showed that all fractures had healed, with an average healing time of (3.66±0.51) months. All patients recovered well, with primary healing of surgical incisions and no complications such as neurovascular injury, skin necrosis, incision infection, fracture displacement, or ligament laxity. Postoperative knee Lysholm and HSS scores were significantly higher than preoperative scores. At the last follow-up, the Lysholm score increased from (46.30±6.10) preoperatively to (90.85±3.27), and the HSS score increased from (45.30±5.80) to (91.15±2.66), with statistically significant differences (P<0.025).
Conclusion: The anchor suture bridge technique is effective in treating avulsion fractures of the PCL tibial insertion point in the knee joint. It has a high safety profile and leads to good postoperative knee function recovery, with no serious postoperative complications, demonstrating excellent clinical efficacy.
四川大学学报(医学版)Biochemistry, Genetics and Molecular Biology-Molecular Biology
CiteScore
0.70
自引率
0.00%
发文量
8695
期刊介绍:
"Journal of Sichuan University (Medical Edition)" is a comprehensive medical academic journal sponsored by Sichuan University, a higher education institution directly under the Ministry of Education of the People's Republic of China. It was founded in 1959 and was originally named "Journal of Sichuan Medical College". In 1986, it was renamed "Journal of West China University of Medical Sciences". In 2003, it was renamed "Journal of Sichuan University (Medical Edition)" (bimonthly).
"Journal of Sichuan University (Medical Edition)" is a Chinese core journal and a Chinese authoritative academic journal (RCCSE). It is included in the retrieval systems such as China Science and Technology Papers and Citation Database (CSTPCD), China Science Citation Database (CSCD) (core version), Peking University Library's "Overview of Chinese Core Journals", the U.S. "Index Medica" (IM/Medline), the U.S. "PubMed Central" (PMC), the U.S. "Biological Abstracts" (BA), the U.S. "Chemical Abstracts" (CA), the U.S. EBSCO, the Netherlands "Abstracts and Citation Database" (Scopus), the Japan Science and Technology Agency Database (JST), the Russian "Abstract Magazine", the Chinese Biomedical Literature CD-ROM Database (CBMdisc), the Chinese Biomedical Periodical Literature Database (CMCC), the China Academic Journal Network Full-text Database (CNKI), the Chinese Academic Journal (CD-ROM Edition), and the Wanfang Data-Digital Journal Group.