{"title":"Artificial intelligence-assisted volume isotropic simultaneous interleaved bright- and black-blood examination for brain metastases.","authors":"Kazufumi Kikuchi, Osamu Togao, Yoshitomo Kikuchi, Koji Yamashita, Daichi Momosaka, Kazunori Fukasawa, Shunsuke Nishimura, Hiroyuki Toyoda, Makoto Obara, Akio Hiwatashi, Kousei Ishigami","doi":"10.1007/s00234-024-03454-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To verify the effectiveness of artificial intelligence-assisted volume isotropic simultaneous interleaved bright-/black-blood examination (AI-VISIBLE) for detecting brain metastases.</p><p><strong>Methods: </strong>This retrospective study was approved by our institutional review board and the requirement for written informed consent was waived. Forty patients were included: 20 patients with and without brain metastases each. Seven independent observers (three radiology residents and four neuroradiologists) participated in two reading sessions: in the first, brain metastases were detected using VISIBLE only; in the second, the results of the first session were comprehensively evaluated by adding AI-VISIBLE information. Sensitivity, diagnostic performance, and false positives/case were evaluated. Diagnostic performance was assessed using a figure-of-merit (FOM). Sensitivity and false positives/case were evaluated using McNemar and paired t-tests, respectively.</p><p><strong>Results: </strong>The McNemar test revealed a significant difference between VISIBLE with/without AI information (P < 0.0001). Significantly higher sensitivity (94.9 ± 1.7% vs. 88.3 ± 5.1%, P = 0.0028) and FOM (0.983 ± 0.009 vs. 0.972 ± 0.013, P = 0.0063) were achieved using VISIBLE with AI information vs. without. No significant difference was observed in false positives/case with and without AI information (0.23 ± 0.19 vs. 0.18 ± 0.15, P = 0.250). AI-assisted results of radiology residents became comparable to results of neuroradiologists (sensitivity, FOM: 85.9 ± 3.4% vs. 90.0 ± 5.9%, 0.969 ± 0.016 vs. 0.974 ± 0.012 without AI information; 94.8 ± 1.3% vs. 95.0 ± 2.1%, 0.977 ± 0.010 vs. 0.988 ± 0.005 with AI information, respectively).</p><p><strong>Conclusion: </strong>AI-VISIBLE improved the sensitivity and performance for diagnosing brain metastases.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00234-024-03454-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To verify the effectiveness of artificial intelligence-assisted volume isotropic simultaneous interleaved bright-/black-blood examination (AI-VISIBLE) for detecting brain metastases.
Methods: This retrospective study was approved by our institutional review board and the requirement for written informed consent was waived. Forty patients were included: 20 patients with and without brain metastases each. Seven independent observers (three radiology residents and four neuroradiologists) participated in two reading sessions: in the first, brain metastases were detected using VISIBLE only; in the second, the results of the first session were comprehensively evaluated by adding AI-VISIBLE information. Sensitivity, diagnostic performance, and false positives/case were evaluated. Diagnostic performance was assessed using a figure-of-merit (FOM). Sensitivity and false positives/case were evaluated using McNemar and paired t-tests, respectively.
Results: The McNemar test revealed a significant difference between VISIBLE with/without AI information (P < 0.0001). Significantly higher sensitivity (94.9 ± 1.7% vs. 88.3 ± 5.1%, P = 0.0028) and FOM (0.983 ± 0.009 vs. 0.972 ± 0.013, P = 0.0063) were achieved using VISIBLE with AI information vs. without. No significant difference was observed in false positives/case with and without AI information (0.23 ± 0.19 vs. 0.18 ± 0.15, P = 0.250). AI-assisted results of radiology residents became comparable to results of neuroradiologists (sensitivity, FOM: 85.9 ± 3.4% vs. 90.0 ± 5.9%, 0.969 ± 0.016 vs. 0.974 ± 0.012 without AI information; 94.8 ± 1.3% vs. 95.0 ± 2.1%, 0.977 ± 0.010 vs. 0.988 ± 0.005 with AI information, respectively).
Conclusion: AI-VISIBLE improved the sensitivity and performance for diagnosing brain metastases.