Tert-butylhydroquinone and tert-butylcatechol positivity as warning lights of skin sensitization to tert-butylphenol derivatives in adhesives and diabetes devices
Ella Dendooven, Tania Naessens, Kenn Foubert, Nina Hermans, Olivier Aerts
{"title":"Tert-butylhydroquinone and tert-butylcatechol positivity as warning lights of skin sensitization to tert-butylphenol derivatives in adhesives and diabetes devices","authors":"Ella Dendooven, Tania Naessens, Kenn Foubert, Nina Hermans, Olivier Aerts","doi":"10.1111/cod.14670","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>Tert-butylphenol (TBP) derivatives, antioxidants in adhesives and diabetes devices, may provoke allergic contact dermatitis (ACD).</p>\n </section>\n \n <section>\n \n <h3> Objectives</h3>\n \n <p>The objective of this study is to report sensitization to TBP derivatives in medical devices and to highlight that tert-butylhydroquinone (BHQ) and tert-butylcatechol (TBC) are potential screeners in this regard.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Fifteen patients with ACD from adhesives and diabetes devices were patch tested to different TBPs: BHQ 1% pet., TBC 0.25% pet., BHA 2% pet., BHT 2% pet., 4-tert-butylphenol (TBP) 1% pet. and 2,4-di-tert-butylphenol (di TBP) 1% pet. The culprit devices (medical adhesives, sanitary pads, diabetes devices) and TBP patch preparations were analysed using gas chromatography-mass spectrometry (GC–MS).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>BHQ (9/13), TBC (7/13), and to a lesser extent BHT (3/15), BHA (2/15) and TBP (2/13) gave positive reactions. Seven patients had developed ACD from adhesives and diabetes devices, respectively, and one patient from sanitary pads. GC–MS analyses of the medical devices and patch test materials confirmed the presence of the patch-test positive TBPs, or chemically related derivatives, or, interestingly, tert-butylbenzoquinones (BBQ) were found, that is, spontaneously formed, highly reactive TBP metabolites, likely (pseudo-) cross reacting with the patch tested TBPs.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>TBPs might be overlooked sensitizers in medical devices, and BHQ and TBC are potential screeners in this regard.</p>\n </section>\n </div>","PeriodicalId":10527,"journal":{"name":"Contact Dermatitis","volume":"91 5","pages":"387-391"},"PeriodicalIF":4.8000,"publicationDate":"2024-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contact Dermatitis","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cod.14670","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ALLERGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
Tert-butylphenol (TBP) derivatives, antioxidants in adhesives and diabetes devices, may provoke allergic contact dermatitis (ACD).
Objectives
The objective of this study is to report sensitization to TBP derivatives in medical devices and to highlight that tert-butylhydroquinone (BHQ) and tert-butylcatechol (TBC) are potential screeners in this regard.
Methods
Fifteen patients with ACD from adhesives and diabetes devices were patch tested to different TBPs: BHQ 1% pet., TBC 0.25% pet., BHA 2% pet., BHT 2% pet., 4-tert-butylphenol (TBP) 1% pet. and 2,4-di-tert-butylphenol (di TBP) 1% pet. The culprit devices (medical adhesives, sanitary pads, diabetes devices) and TBP patch preparations were analysed using gas chromatography-mass spectrometry (GC–MS).
Results
BHQ (9/13), TBC (7/13), and to a lesser extent BHT (3/15), BHA (2/15) and TBP (2/13) gave positive reactions. Seven patients had developed ACD from adhesives and diabetes devices, respectively, and one patient from sanitary pads. GC–MS analyses of the medical devices and patch test materials confirmed the presence of the patch-test positive TBPs, or chemically related derivatives, or, interestingly, tert-butylbenzoquinones (BBQ) were found, that is, spontaneously formed, highly reactive TBP metabolites, likely (pseudo-) cross reacting with the patch tested TBPs.
Conclusion
TBPs might be overlooked sensitizers in medical devices, and BHQ and TBC are potential screeners in this regard.
期刊介绍:
Contact Dermatitis is designed primarily as a journal for clinicians who are interested in various aspects of environmental dermatitis. This includes both allergic and irritant (toxic) types of contact dermatitis, occupational (industrial) dermatitis and consumers" dermatitis from such products as cosmetics and toiletries. The journal aims at promoting and maintaining communication among dermatologists, industrial physicians, allergists and clinical immunologists, as well as chemists and research workers involved in industry and the production of consumer goods. Papers are invited on clinical observations, diagnosis and methods of investigation of patients, therapeutic measures, organisation and legislation relating to the control of occupational and consumers".