{"title":"Age-dependence of semitendinosus tendon properties used for anterior cruciate ligament reconstruction differs in males and females","authors":"Naokazu Miyamoto , Eri Miyamoto-Mikami , Mayuko Kinoshita , Takuto Akazawa , Noriko Kimura , Hirofumi Nishio , Yohei Kobayashi , Masashi Nagao , Yuji Takazawa","doi":"10.1016/j.clinbiomech.2024.106329","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>The semitendinosus tendon is one of the most used autografts in anterior cruciate ligament reconstruction. Although recent evidence indicates that young patients, especially in females, may experience high rates of revision and residual instability, the reasons for the inferior outcomes in these patients remain unclear. To address this issue, we aimed to compare the mechanical properties of the semitendinosus tendon used for anterior cruciate ligament reconstruction in male and female patients of various ages.</p></div><div><h3>Methods</h3><p>The semitendinosus tendons harvested from 31 male and 29 female patients who underwent anterior cruciate ligament reconstruction surgery using the semitendinosus tendon autografts were used in this study. Using the distal part of the harvested semitendinosus tendon, the extent of cyclic loading-induced elongation (i.e., the extent of the increase in slack length) and the Young's modulus were measured during cyclic tensile testing.</p></div><div><h3>Findings</h3><p>Spearman correlation analyses revealed that the Young's modulus (|ρ| = 0.725, <em>P</em> < 0.001), but not elongation (|ρ| ≤ 0.036, <em>P</em> ≥ 0.351) positively correlated with the patient age in male tendon samples. In contrast, for female tendon samples, the elongation (|ρ| ≥ 0.415, <em>P</em> ≤ 0.025), but not the Young's modulus (|ρ| = 0.087, <em>P</em> = 0.655) negatively correlated with the patient age.</p></div><div><h3>Interpretation</h3><p>These results indicate that the semitendinosus tendon used for anterior cruciate ligament reconstruction in young male patients is compliant, whereas that in young female patients is susceptible to elongation induced by cyclic loading.</p></div>","PeriodicalId":50992,"journal":{"name":"Clinical Biomechanics","volume":"119 ","pages":"Article 106329"},"PeriodicalIF":1.4000,"publicationDate":"2024-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S026800332400161X","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background
The semitendinosus tendon is one of the most used autografts in anterior cruciate ligament reconstruction. Although recent evidence indicates that young patients, especially in females, may experience high rates of revision and residual instability, the reasons for the inferior outcomes in these patients remain unclear. To address this issue, we aimed to compare the mechanical properties of the semitendinosus tendon used for anterior cruciate ligament reconstruction in male and female patients of various ages.
Methods
The semitendinosus tendons harvested from 31 male and 29 female patients who underwent anterior cruciate ligament reconstruction surgery using the semitendinosus tendon autografts were used in this study. Using the distal part of the harvested semitendinosus tendon, the extent of cyclic loading-induced elongation (i.e., the extent of the increase in slack length) and the Young's modulus were measured during cyclic tensile testing.
Findings
Spearman correlation analyses revealed that the Young's modulus (|ρ| = 0.725, P < 0.001), but not elongation (|ρ| ≤ 0.036, P ≥ 0.351) positively correlated with the patient age in male tendon samples. In contrast, for female tendon samples, the elongation (|ρ| ≥ 0.415, P ≤ 0.025), but not the Young's modulus (|ρ| = 0.087, P = 0.655) negatively correlated with the patient age.
Interpretation
These results indicate that the semitendinosus tendon used for anterior cruciate ligament reconstruction in young male patients is compliant, whereas that in young female patients is susceptible to elongation induced by cyclic loading.
期刊介绍:
Clinical Biomechanics is an international multidisciplinary journal of biomechanics with a focus on medical and clinical applications of new knowledge in the field.
The science of biomechanics helps explain the causes of cell, tissue, organ and body system disorders, and supports clinicians in the diagnosis, prognosis and evaluation of treatment methods and technologies. Clinical Biomechanics aims to strengthen the links between laboratory and clinic by publishing cutting-edge biomechanics research which helps to explain the causes of injury and disease, and which provides evidence contributing to improved clinical management.
A rigorous peer review system is employed and every attempt is made to process and publish top-quality papers promptly.
Clinical Biomechanics explores all facets of body system, organ, tissue and cell biomechanics, with an emphasis on medical and clinical applications of the basic science aspects. The role of basic science is therefore recognized in a medical or clinical context. The readership of the journal closely reflects its multi-disciplinary contents, being a balance of scientists, engineers and clinicians.
The contents are in the form of research papers, brief reports, review papers and correspondence, whilst special interest issues and supplements are published from time to time.
Disciplines covered include biomechanics and mechanobiology at all scales, bioengineering and use of tissue engineering and biomaterials for clinical applications, biophysics, as well as biomechanical aspects of medical robotics, ergonomics, physical and occupational therapeutics and rehabilitation.