{"title":"Age-dependence of semitendinosus tendon properties used for anterior cruciate ligament reconstruction differs in males and females","authors":"Naokazu Miyamoto , Eri Miyamoto-Mikami , Mayuko Kinoshita , Takuto Akazawa , Noriko Kimura , Hirofumi Nishio , Yohei Kobayashi , Masashi Nagao , Yuji Takazawa","doi":"10.1016/j.clinbiomech.2024.106329","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>The semitendinosus tendon is one of the most used autografts in anterior cruciate ligament reconstruction. Although recent evidence indicates that young patients, especially in females, may experience high rates of revision and residual instability, the reasons for the inferior outcomes in these patients remain unclear. To address this issue, we aimed to compare the mechanical properties of the semitendinosus tendon used for anterior cruciate ligament reconstruction in male and female patients of various ages.</p></div><div><h3>Methods</h3><p>The semitendinosus tendons harvested from 31 male and 29 female patients who underwent anterior cruciate ligament reconstruction surgery using the semitendinosus tendon autografts were used in this study. Using the distal part of the harvested semitendinosus tendon, the extent of cyclic loading-induced elongation (i.e., the extent of the increase in slack length) and the Young's modulus were measured during cyclic tensile testing.</p></div><div><h3>Findings</h3><p>Spearman correlation analyses revealed that the Young's modulus (|ρ| = 0.725, <em>P</em> < 0.001), but not elongation (|ρ| ≤ 0.036, <em>P</em> ≥ 0.351) positively correlated with the patient age in male tendon samples. In contrast, for female tendon samples, the elongation (|ρ| ≥ 0.415, <em>P</em> ≤ 0.025), but not the Young's modulus (|ρ| = 0.087, <em>P</em> = 0.655) negatively correlated with the patient age.</p></div><div><h3>Interpretation</h3><p>These results indicate that the semitendinosus tendon used for anterior cruciate ligament reconstruction in young male patients is compliant, whereas that in young female patients is susceptible to elongation induced by cyclic loading.</p></div>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S026800332400161X","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Background
The semitendinosus tendon is one of the most used autografts in anterior cruciate ligament reconstruction. Although recent evidence indicates that young patients, especially in females, may experience high rates of revision and residual instability, the reasons for the inferior outcomes in these patients remain unclear. To address this issue, we aimed to compare the mechanical properties of the semitendinosus tendon used for anterior cruciate ligament reconstruction in male and female patients of various ages.
Methods
The semitendinosus tendons harvested from 31 male and 29 female patients who underwent anterior cruciate ligament reconstruction surgery using the semitendinosus tendon autografts were used in this study. Using the distal part of the harvested semitendinosus tendon, the extent of cyclic loading-induced elongation (i.e., the extent of the increase in slack length) and the Young's modulus were measured during cyclic tensile testing.
Findings
Spearman correlation analyses revealed that the Young's modulus (|ρ| = 0.725, P < 0.001), but not elongation (|ρ| ≤ 0.036, P ≥ 0.351) positively correlated with the patient age in male tendon samples. In contrast, for female tendon samples, the elongation (|ρ| ≥ 0.415, P ≤ 0.025), but not the Young's modulus (|ρ| = 0.087, P = 0.655) negatively correlated with the patient age.
Interpretation
These results indicate that the semitendinosus tendon used for anterior cruciate ligament reconstruction in young male patients is compliant, whereas that in young female patients is susceptible to elongation induced by cyclic loading.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.