The effect of changes in intra-compartmental bioimpedance measurements with early intra-dialytic hypotension during haemodialysis.

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Accounts of Chemical Research Pub Date : 2024-11-01 Epub Date: 2024-08-21 DOI:10.1177/03913988241269444
Sabrina Haroon, Andrew Davenport
{"title":"The effect of changes in intra-compartmental bioimpedance measurements with early intra-dialytic hypotension during haemodialysis.","authors":"Sabrina Haroon, Andrew Davenport","doi":"10.1177/03913988241269444","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Intra-dialytic hypotension (IDH) remains the commonest problem associated with routine haemodialysis treatments. Fluid shifts from intracellular(ICW) and extracellular(ECW) compartments to refill plasma volume during haemodialysis with ultrafiltration.</p><p><strong>Methods: </strong>We studied the effect of relative changes in ICW and ECW indifferent body segments using multifrequency segmental bioimpedance during haemodialysis and IDH episodes.</p><p><strong>Results: </strong>Of 42 haemodialysis patients,16 patients (38.1%) developed IDH within the first hour of dialysis. Patients with and without early IDH were well-matched for demographics and starting bioimpedance measurements. However, after 60 min, the relative change in in ECW/ICW ratio between the non-fistula arm and leg was significantly different for the early IDH group median -1.07 (-3.33 to 0.8) versus 0.61 (-0.78 to 1.8), <i>p</i> < 0.05, whereas there no differences in ultrafiltration rate, relative blood volume monitoring or on-line clearance.</p><p><strong>Conclusion: </strong>Monitoring serial changes in fluid status in different body compartments with bioimpedance may potentially prevent IDH in the future.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/03913988241269444","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/21 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Intra-dialytic hypotension (IDH) remains the commonest problem associated with routine haemodialysis treatments. Fluid shifts from intracellular(ICW) and extracellular(ECW) compartments to refill plasma volume during haemodialysis with ultrafiltration.

Methods: We studied the effect of relative changes in ICW and ECW indifferent body segments using multifrequency segmental bioimpedance during haemodialysis and IDH episodes.

Results: Of 42 haemodialysis patients,16 patients (38.1%) developed IDH within the first hour of dialysis. Patients with and without early IDH were well-matched for demographics and starting bioimpedance measurements. However, after 60 min, the relative change in in ECW/ICW ratio between the non-fistula arm and leg was significantly different for the early IDH group median -1.07 (-3.33 to 0.8) versus 0.61 (-0.78 to 1.8), p < 0.05, whereas there no differences in ultrafiltration rate, relative blood volume monitoring or on-line clearance.

Conclusion: Monitoring serial changes in fluid status in different body compartments with bioimpedance may potentially prevent IDH in the future.

在血液透析过程中,血液透析室内生物阻抗测量值的变化对早期透析室内低血压的影响。
导言:透析内低血压(IDH)仍然是常规血液透析治疗中最常见的问题。在超滤血液透析过程中,液体会从细胞内(ICW)和细胞外(ECW)分区转移,以补充血浆容量:我们利用多频节段生物阻抗研究了血液透析和IDH治疗期间ICW和ECW相对变化对身体各节段的影响:在42名血液透析患者中,有16名患者(38.1%)在透析的第一个小时内出现了IDH。有早期 IDH 和没有早期 IDH 的患者在人口统计学和起始生物阻抗测量方面非常匹配。然而,60 分钟后,非瘘管手臂和腿部的 ECW/ICW 比率的相对变化在早期 IDH 组的中位数-1.07(-3.33 至 0.8)与 0.61(-0.78 至 1.8)之间存在显著差异,P 结论:利用生物阻抗监测身体各部分液体状态的连续变化有可能在未来预防 IDH。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信