Martina Galletto, Christina Ververi, Marta Massano, Eugenio Alladio, Marco Vincenti, Alberto Salomone
{"title":"Development and validation of the UHPLC-MS/MS method for the quantitative determination of 25 PFAS in dried blood spots.","authors":"Martina Galletto, Christina Ververi, Marta Massano, Eugenio Alladio, Marco Vincenti, Alberto Salomone","doi":"10.1007/s00216-024-05484-6","DOIUrl":null,"url":null,"abstract":"<p><p>Per- and polyfluoroalkyl substances (PFAS) are anthropogenic fluorine-containing compounds largely used in industrial and consumer applications. They tend to bioaccumulate in the human body after intake from various sources in daily life. Following repeated exposure to PFAS, a broad range of adverse health outcomes has been reported. Consequently, monitoring PFAS levels in human blood is of paramount importance for public health policies. In contrast with traditional venipuncture, dried blood spots (DBS) constitute a reliable, cheap, and less invasive technique to allow microsampling by capillary blood collected on a specific device. This work aimed to develop and validate an innovative analytical method, combining quantitative DBS with UHPLC-MS/MS instrumentation to identify and quantify 25 PFAS. The extraction procedure was developed and optimized within the range 2-100 ng/mL. Specifically, fortified blood was applied on Capitainer®B devices providing 10 μL of blood volume through a microfluidic channel. After 3 h of drying, the extraction was performed by methanol under sonication, followed by centrifugation. Then, the extraction solvent was evaporated; the residue was reconstituted with the mobile phase solution. The validated method evidenced good sensitivity, with limits of detection ranging from 0.4 ng/mL (PFODA, PFOS) to 1.0 ng/mL (PFOA, 3,6-OPFHpA). The ± 20% acceptability criteria established for intra- and inter-day precision and accuracy were fulfilled for all analytes. High recovery-above 80%-was recorded, whereas significant matrix effect resulted in ion enhancement (> 50%) for 13 analytes. In conclusion, the proposed workflow proved to be reliable, fit for purpose, and easily adaptable in the laboratory routine.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11493788/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-024-05484-6","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/19 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Per- and polyfluoroalkyl substances (PFAS) are anthropogenic fluorine-containing compounds largely used in industrial and consumer applications. They tend to bioaccumulate in the human body after intake from various sources in daily life. Following repeated exposure to PFAS, a broad range of adverse health outcomes has been reported. Consequently, monitoring PFAS levels in human blood is of paramount importance for public health policies. In contrast with traditional venipuncture, dried blood spots (DBS) constitute a reliable, cheap, and less invasive technique to allow microsampling by capillary blood collected on a specific device. This work aimed to develop and validate an innovative analytical method, combining quantitative DBS with UHPLC-MS/MS instrumentation to identify and quantify 25 PFAS. The extraction procedure was developed and optimized within the range 2-100 ng/mL. Specifically, fortified blood was applied on Capitainer®B devices providing 10 μL of blood volume through a microfluidic channel. After 3 h of drying, the extraction was performed by methanol under sonication, followed by centrifugation. Then, the extraction solvent was evaporated; the residue was reconstituted with the mobile phase solution. The validated method evidenced good sensitivity, with limits of detection ranging from 0.4 ng/mL (PFODA, PFOS) to 1.0 ng/mL (PFOA, 3,6-OPFHpA). The ± 20% acceptability criteria established for intra- and inter-day precision and accuracy were fulfilled for all analytes. High recovery-above 80%-was recorded, whereas significant matrix effect resulted in ion enhancement (> 50%) for 13 analytes. In conclusion, the proposed workflow proved to be reliable, fit for purpose, and easily adaptable in the laboratory routine.
期刊介绍:
Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.