{"title":"Viability of shear wave elastography to predict mechanical/ultimate failure in the anterolateral and medial collateral ligaments of the knee","authors":"","doi":"10.1016/j.jbiomech.2024.112264","DOIUrl":null,"url":null,"abstract":"<div><p>The purpose of this study was (1) to determine the utility of shear wave elastography as a predictor for the mechanical failure of superficial knee ligaments and (2) to determine the viability of shear wave elastography to assess injury risk potential. Our hypothesis was that shear wave elastography measurements of the anterolateral ligament and medial collateral ligament would directly correlate with the material properties and the mechanical failure of the ligament, serving as a prognostic measurement for injury risk. 8 cadaveric specimens were acquired, and tissue stiffness for the anterolateral ligament and medial collateral ligament were evaluated with shear wave elastography. The anterolateral ligament and medial collateral ligament were dissected and isolated for unilateral mechanical failure testing. Ultimate failure testing was performed at 100 % strain per second after 50 cycles of 3 % strain viscoelastic conditioning. Each specimen was assessed for load, displacement, and surface strain throughout failure testing. Rate of force, rate of strain development, and Young’s modulus were calculated from these variables. Shear wave elastography stiffness for the anterolateral ligament correlated with mean longitudinal anterolateral ligament strain at failure (R<sup>2</sup> = 0.853; <em>P</em><0.05). Medial collateral ligament shear wave elastography calculated modulus was significantly greater than the anterolateral ligament shear wave elastography calculated modulus. Shear wave elastography currently offers limited reliability in the prediction of mechanical performance of superficial knee ligaments. The utility of shear wave elastography assessment for injury risk potential remains undetermined.</p></div>","PeriodicalId":15168,"journal":{"name":"Journal of biomechanics","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomechanics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021929024003427","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
The purpose of this study was (1) to determine the utility of shear wave elastography as a predictor for the mechanical failure of superficial knee ligaments and (2) to determine the viability of shear wave elastography to assess injury risk potential. Our hypothesis was that shear wave elastography measurements of the anterolateral ligament and medial collateral ligament would directly correlate with the material properties and the mechanical failure of the ligament, serving as a prognostic measurement for injury risk. 8 cadaveric specimens were acquired, and tissue stiffness for the anterolateral ligament and medial collateral ligament were evaluated with shear wave elastography. The anterolateral ligament and medial collateral ligament were dissected and isolated for unilateral mechanical failure testing. Ultimate failure testing was performed at 100 % strain per second after 50 cycles of 3 % strain viscoelastic conditioning. Each specimen was assessed for load, displacement, and surface strain throughout failure testing. Rate of force, rate of strain development, and Young’s modulus were calculated from these variables. Shear wave elastography stiffness for the anterolateral ligament correlated with mean longitudinal anterolateral ligament strain at failure (R2 = 0.853; P<0.05). Medial collateral ligament shear wave elastography calculated modulus was significantly greater than the anterolateral ligament shear wave elastography calculated modulus. Shear wave elastography currently offers limited reliability in the prediction of mechanical performance of superficial knee ligaments. The utility of shear wave elastography assessment for injury risk potential remains undetermined.
期刊介绍:
The Journal of Biomechanics publishes reports of original and substantial findings using the principles of mechanics to explore biological problems. Analytical, as well as experimental papers may be submitted, and the journal accepts original articles, surveys and perspective articles (usually by Editorial invitation only), book reviews and letters to the Editor. The criteria for acceptance of manuscripts include excellence, novelty, significance, clarity, conciseness and interest to the readership.
Papers published in the journal may cover a wide range of topics in biomechanics, including, but not limited to:
-Fundamental Topics - Biomechanics of the musculoskeletal, cardiovascular, and respiratory systems, mechanics of hard and soft tissues, biofluid mechanics, mechanics of prostheses and implant-tissue interfaces, mechanics of cells.
-Cardiovascular and Respiratory Biomechanics - Mechanics of blood-flow, air-flow, mechanics of the soft tissues, flow-tissue or flow-prosthesis interactions.
-Cell Biomechanics - Biomechanic analyses of cells, membranes and sub-cellular structures; the relationship of the mechanical environment to cell and tissue response.
-Dental Biomechanics - Design and analysis of dental tissues and prostheses, mechanics of chewing.
-Functional Tissue Engineering - The role of biomechanical factors in engineered tissue replacements and regenerative medicine.
-Injury Biomechanics - Mechanics of impact and trauma, dynamics of man-machine interaction.
-Molecular Biomechanics - Mechanical analyses of biomolecules.
-Orthopedic Biomechanics - Mechanics of fracture and fracture fixation, mechanics of implants and implant fixation, mechanics of bones and joints, wear of natural and artificial joints.
-Rehabilitation Biomechanics - Analyses of gait, mechanics of prosthetics and orthotics.
-Sports Biomechanics - Mechanical analyses of sports performance.