Viability of shear wave elastography to predict mechanical/ultimate failure in the anterolateral and medial collateral ligaments of the knee

IF 2.4 3区 医学 Q3 BIOPHYSICS
{"title":"Viability of shear wave elastography to predict mechanical/ultimate failure in the anterolateral and medial collateral ligaments of the knee","authors":"","doi":"10.1016/j.jbiomech.2024.112264","DOIUrl":null,"url":null,"abstract":"<div><p>The purpose of this study was (1) to determine the utility of shear wave elastography as a predictor for the mechanical failure of superficial knee ligaments and (2) to determine the viability of shear wave elastography to assess injury risk potential. Our hypothesis was that shear wave elastography measurements of the anterolateral ligament and medial collateral ligament would directly correlate with the material properties and the mechanical failure of the ligament, serving as a prognostic measurement for injury risk. 8 cadaveric specimens were acquired, and tissue stiffness for the anterolateral ligament and medial collateral ligament were evaluated with shear wave elastography. The anterolateral ligament and medial collateral ligament were dissected and isolated for unilateral mechanical failure testing. Ultimate failure testing was performed at 100 % strain per second after 50 cycles of 3 % strain viscoelastic conditioning. Each specimen was assessed for load, displacement, and surface strain throughout failure testing. Rate of force, rate of strain development, and Young’s modulus were calculated from these variables. Shear wave elastography stiffness for the anterolateral ligament correlated with mean longitudinal anterolateral ligament strain at failure (R<sup>2</sup> = 0.853; <em>P</em>&lt;0.05). Medial collateral ligament shear wave elastography calculated modulus was significantly greater than the anterolateral ligament shear wave elastography calculated modulus. Shear wave elastography currently offers limited reliability in the prediction of mechanical performance of superficial knee ligaments. The utility of shear wave elastography assessment for injury risk potential remains undetermined.</p></div>","PeriodicalId":15168,"journal":{"name":"Journal of biomechanics","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomechanics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021929024003427","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of this study was (1) to determine the utility of shear wave elastography as a predictor for the mechanical failure of superficial knee ligaments and (2) to determine the viability of shear wave elastography to assess injury risk potential. Our hypothesis was that shear wave elastography measurements of the anterolateral ligament and medial collateral ligament would directly correlate with the material properties and the mechanical failure of the ligament, serving as a prognostic measurement for injury risk. 8 cadaveric specimens were acquired, and tissue stiffness for the anterolateral ligament and medial collateral ligament were evaluated with shear wave elastography. The anterolateral ligament and medial collateral ligament were dissected and isolated for unilateral mechanical failure testing. Ultimate failure testing was performed at 100 % strain per second after 50 cycles of 3 % strain viscoelastic conditioning. Each specimen was assessed for load, displacement, and surface strain throughout failure testing. Rate of force, rate of strain development, and Young’s modulus were calculated from these variables. Shear wave elastography stiffness for the anterolateral ligament correlated with mean longitudinal anterolateral ligament strain at failure (R2 = 0.853; P<0.05). Medial collateral ligament shear wave elastography calculated modulus was significantly greater than the anterolateral ligament shear wave elastography calculated modulus. Shear wave elastography currently offers limited reliability in the prediction of mechanical performance of superficial knee ligaments. The utility of shear wave elastography assessment for injury risk potential remains undetermined.

剪切波弹性成像预测膝关节前外侧韧带和内侧副韧带机械故障/最终故障的可行性
本研究的目的是:(1)确定剪切波弹性成像作为膝关节浅层韧带机械损伤预测指标的实用性;(2)确定剪切波弹性成像评估损伤风险可能性的可行性。我们的假设是,前外侧韧带和内侧副韧带的剪切波弹性成像测量结果将与韧带的材料特性和机械损伤直接相关,可作为损伤风险的预后测量指标。我们采集了 8 具尸体标本,并使用剪切波弹性成像技术评估了前外侧韧带和内侧副韧带的组织硬度。解剖并分离前外侧韧带和内侧副韧带,进行单侧机械破坏测试。经过 50 个周期的 3% 应变粘弹性调节后,以每秒 100% 的应变进行最终破坏测试。在整个失效测试过程中,对每个试样的载荷、位移和表面应变进行评估。根据这些变量计算出受力率、应变发展率和杨氏模量。前外侧韧带的剪切波弹性成像刚度与失效时前外侧韧带的平均纵向应变相关(R2 = 0.853; P<0.05)。内侧副韧带剪切波弹性成像计算模量明显大于前外侧韧带剪切波弹性成像计算模量。目前,剪切波弹性成像在预测膝关节浅层韧带机械性能方面的可靠性有限。剪切波弹性成像对潜在损伤风险的评估作用仍未确定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of biomechanics
Journal of biomechanics 生物-工程:生物医学
CiteScore
5.10
自引率
4.20%
发文量
345
审稿时长
1 months
期刊介绍: The Journal of Biomechanics publishes reports of original and substantial findings using the principles of mechanics to explore biological problems. Analytical, as well as experimental papers may be submitted, and the journal accepts original articles, surveys and perspective articles (usually by Editorial invitation only), book reviews and letters to the Editor. The criteria for acceptance of manuscripts include excellence, novelty, significance, clarity, conciseness and interest to the readership. Papers published in the journal may cover a wide range of topics in biomechanics, including, but not limited to: -Fundamental Topics - Biomechanics of the musculoskeletal, cardiovascular, and respiratory systems, mechanics of hard and soft tissues, biofluid mechanics, mechanics of prostheses and implant-tissue interfaces, mechanics of cells. -Cardiovascular and Respiratory Biomechanics - Mechanics of blood-flow, air-flow, mechanics of the soft tissues, flow-tissue or flow-prosthesis interactions. -Cell Biomechanics - Biomechanic analyses of cells, membranes and sub-cellular structures; the relationship of the mechanical environment to cell and tissue response. -Dental Biomechanics - Design and analysis of dental tissues and prostheses, mechanics of chewing. -Functional Tissue Engineering - The role of biomechanical factors in engineered tissue replacements and regenerative medicine. -Injury Biomechanics - Mechanics of impact and trauma, dynamics of man-machine interaction. -Molecular Biomechanics - Mechanical analyses of biomolecules. -Orthopedic Biomechanics - Mechanics of fracture and fracture fixation, mechanics of implants and implant fixation, mechanics of bones and joints, wear of natural and artificial joints. -Rehabilitation Biomechanics - Analyses of gait, mechanics of prosthetics and orthotics. -Sports Biomechanics - Mechanical analyses of sports performance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信