Prediction of CD34+ hematopoietic stem cells in healthy allogeneic stem cell donors on the Optia cell separator based on CE2: Which formula is more correlated with actual CD34+?
{"title":"Prediction of CD34+ hematopoietic stem cells in healthy allogeneic stem cell donors on the Optia cell separator based on CE2: Which formula is more correlated with actual CD34+?","authors":"Sıdıka Gülkan Özkan, Ali Kimiaei, Seyedehtina Safaei, Tarık Ercan, Meral Sönmezoğlu, Gülderen Yanıkkaya Demirel, Sema Aktaş, Sinem Özdemir, Helin Serda Özalp, Hasan Atilla Özkan","doi":"10.1111/trf.17990","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Peripheral blood-derived hematopoietic stem cells (HSCs) are widely used for various adult stem cell transplants. To obtain sufficient HSCs from healthy volunteer donors during the apheresis process and ensure that the donors are exposed to fewer apheresis-related side effects, calculation methods have been developed for the prediction of processed blood volume or CD34+ count. However, there is no consensus on a formula to predict the volume of blood to be processed or the number of stem cells to be obtained.</p><p><strong>Objective: </strong>This study aimed to estimate the predicted blood volume and CD34+ cell counts using collection efficiency (CE)-based formulas and evaluate their accuracy compared to the actual CD34+ cell counts. It also seeks to identify the factors that affect CE.</p><p><strong>Methods: </strong>Data from 397 healthy, unrelated stem cell donors were retrospectively analyzed. An algorithm using four different CE2 metrics (1st quartile, mean, 3rd quartile, and median) was developed to predict the volume of blood to be processed using the Spectra Optia continuous mononuclear cell collection procedure.</p><p><strong>Results: </strong>When employing the mean CE2 algorithm, the results revealed a strong correlation (r = .894, p < .001) between predicted and actual CD34+ values. The study also identified strong associations between pre-apheresis CD34+, pre-apheresis leukocyte count, the use of two doses of G-CSF, and low CE2.</p><p><strong>Conclusion: </strong>These findings suggest that the mean CE2 algorithm could be a potent, straightforward, and accurate tool for predicting CD34+ stem cell counts in healthy allogeneic stem cell donors and potentially optimizing stem cell collection procedures.</p>","PeriodicalId":23266,"journal":{"name":"Transfusion","volume":" ","pages":"1959-1967"},"PeriodicalIF":2.5000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transfusion","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/trf.17990","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/17 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Peripheral blood-derived hematopoietic stem cells (HSCs) are widely used for various adult stem cell transplants. To obtain sufficient HSCs from healthy volunteer donors during the apheresis process and ensure that the donors are exposed to fewer apheresis-related side effects, calculation methods have been developed for the prediction of processed blood volume or CD34+ count. However, there is no consensus on a formula to predict the volume of blood to be processed or the number of stem cells to be obtained.
Objective: This study aimed to estimate the predicted blood volume and CD34+ cell counts using collection efficiency (CE)-based formulas and evaluate their accuracy compared to the actual CD34+ cell counts. It also seeks to identify the factors that affect CE.
Methods: Data from 397 healthy, unrelated stem cell donors were retrospectively analyzed. An algorithm using four different CE2 metrics (1st quartile, mean, 3rd quartile, and median) was developed to predict the volume of blood to be processed using the Spectra Optia continuous mononuclear cell collection procedure.
Results: When employing the mean CE2 algorithm, the results revealed a strong correlation (r = .894, p < .001) between predicted and actual CD34+ values. The study also identified strong associations between pre-apheresis CD34+, pre-apheresis leukocyte count, the use of two doses of G-CSF, and low CE2.
Conclusion: These findings suggest that the mean CE2 algorithm could be a potent, straightforward, and accurate tool for predicting CD34+ stem cell counts in healthy allogeneic stem cell donors and potentially optimizing stem cell collection procedures.
期刊介绍:
TRANSFUSION is the foremost publication in the world for new information regarding transfusion medicine. Written by and for members of AABB and other health-care workers, TRANSFUSION reports on the latest technical advances, discusses opposing viewpoints regarding controversial issues, and presents key conference proceedings. In addition to blood banking and transfusion medicine topics, TRANSFUSION presents submissions concerning patient blood management, tissue transplantation and hematopoietic, cellular, and gene therapies.