{"title":"Oscillatory potential findings in patients with acute ischaemic central retinal vein occlusion.","authors":"Ya Qu, Li Ran, Gang Wang, Min Wang, Shiying Li","doi":"10.1136/bmjophth-2023-001582","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>To explore the sensitive components of full-field electroretinography (ERG) as indicators of retina function at the onset of acute ischaemic central retinal vein occlusion (CRVO).</p><p><strong>Methods: </strong>11 patients (11 eyes) with ischaemic CRVO and 32 patients (32 eyes) with non-ischaemic CRVO who presented with first-episode unilateral CRVO within 1 month of symptom onset and with no previous intervention were examined by the International Society for Clinical Electrophysiology of Vision standard ERG.</p><p><strong>Results: </strong>A significant amplitude decline and peak time delay in light-adapted (LA) 3 ERG and LA 30 Hz flicker ERG (p<0.05 for all) was found in the ischaemic CRVO eyes, compared with the non-ischaemic CRVO eyes. The b/a amplitude ratio of dark-adapted (DA) 3 ERG, DA 10 ERG and LA 3 ERG was significantly different between the ischaemic and non-ischaemic groups (p<0.05 for all). Regarding oscillatory potentials (OPs), the amplitudes of OP1, OP2 and OP3 as well as the sum of DA 3 OP1-4 amplitudes (∑OPs) showed significant changes (p<0.01 for all) between two groups. No peak time delay of OPs was found between the ischaemic and non-ischaemic CRVO eyes.</p><p><strong>Conclusion: </strong>The amplitude of DA 0.01 ERG, components of LA 3 ERG and LA 30 Hz flicker ERG, and the b/a amplitude ratio could be among the most sensitive indicators in patients with acute ischaemic CRVO. The amplitudes of OP1, OP2, OP3 and ∑OPs in the CRVO eyes were reduced to 40% of the control values, showing that this quantitative method is reliable for detecting ischaemic retinal diseases, even in early stage.</p>","PeriodicalId":9286,"journal":{"name":"BMJ Open Ophthalmology","volume":"9 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11331877/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Open Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjophth-2023-001582","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Aims: To explore the sensitive components of full-field electroretinography (ERG) as indicators of retina function at the onset of acute ischaemic central retinal vein occlusion (CRVO).
Methods: 11 patients (11 eyes) with ischaemic CRVO and 32 patients (32 eyes) with non-ischaemic CRVO who presented with first-episode unilateral CRVO within 1 month of symptom onset and with no previous intervention were examined by the International Society for Clinical Electrophysiology of Vision standard ERG.
Results: A significant amplitude decline and peak time delay in light-adapted (LA) 3 ERG and LA 30 Hz flicker ERG (p<0.05 for all) was found in the ischaemic CRVO eyes, compared with the non-ischaemic CRVO eyes. The b/a amplitude ratio of dark-adapted (DA) 3 ERG, DA 10 ERG and LA 3 ERG was significantly different between the ischaemic and non-ischaemic groups (p<0.05 for all). Regarding oscillatory potentials (OPs), the amplitudes of OP1, OP2 and OP3 as well as the sum of DA 3 OP1-4 amplitudes (∑OPs) showed significant changes (p<0.01 for all) between two groups. No peak time delay of OPs was found between the ischaemic and non-ischaemic CRVO eyes.
Conclusion: The amplitude of DA 0.01 ERG, components of LA 3 ERG and LA 30 Hz flicker ERG, and the b/a amplitude ratio could be among the most sensitive indicators in patients with acute ischaemic CRVO. The amplitudes of OP1, OP2, OP3 and ∑OPs in the CRVO eyes were reduced to 40% of the control values, showing that this quantitative method is reliable for detecting ischaemic retinal diseases, even in early stage.